isolation_monitorΒΆ
Isolation monitor types
IsolationMeasurement: object
Results of an isolation measurement
properties:
resistance_F_Ohm: number <required>
Isolation resistance between DC+/DC- and protective earth in Ohm
voltage_V: number <optional>
DC voltage between positive and negative terminal in Volt
voltage_to_earth_l1e_V: number <optional>
DC voltage to earth on L1 in Volt
voltage_to_earth_l2e_V: number <optional>
DC voltage to earth on L2 in Volt