ac_rcd¶
This interface provides an AC Residual Current Monitor (RCD). Actual emergency switch off is done in HW directly, but this interface allows some control and telemetry.
Variables¶
rcd_current_mA: number
Residual current in mA. Note that this does not trigger anything, it is merely for reporting.
Commands¶
self_test:void
Executes a self test of the RCD. If it fails, an error of type Selftest should be raised.
reset:boolean
Resets the RCD after a trigger. May not be supported by actual hardware.
Result: boolean
True: Reset successful, False: Reset failed.
Errors¶
/errors/ac_rcd :
Selftest : The Selftest failed, device permanently broken
DC : RCD was triggered by a DC fault
AC : RCD was triggered by an AC fault
MREC2GroundFailure : MREC compliant fault code
VendorError : Vendor specific error code. Will stop charging session.
VendorWarning : Vendor specific error code. Charging may continue.