How the device model is composed¶
OCPPmulti keeps one device model, in one database, for OCPP 1.6 and OCPP 2.x alike. An OCPP 2.x CSMS reads and
writes it with GetVariables and SetVariables, an OCPP 1.6 CSMS with GetConfiguration and
ChangeConfiguration, and EVerest modules reach it through the ocpp interface. Five contributors fill it:
the component configuration, the JSON files in which the integrator defines the station;
libocpp, which computes the availability states;
the components EVerest provides, reported by the modules the OCPP module is connected to;
the EVerest module configuration views, backed by the configuration service;
external providers, components that bring their own configuration and telemetry.
Every variable has exactly one owner. libocpp’s device model composes the model from what the owners bring, serves every read from memory and routes every write to the owner.
Note
External providers and the ocpp_device_model_provider API arrive in their own pull request, after the single
device model database. They are described here already so that the page shows the complete design.
flowchart LR
JSON["Component configuration (JSON)"]
LIB[libocpp]
EV[Components EVerest provides]
VIEWS[Module configuration views]
PRV[Provider binding]
DM[Device model]
DB[(device model database)]
CS[(configuration service)]
MODS[EVerest modules]
EXT[External provider]
CSMS[CSMS]
API[ocpp interface]
JSON -- seeds --> DB
DB -- values, monitors --> DM
LIB -- AvailabilityState --> DM
MODS -- capabilities, power, EV information --> EV
EV -- registers, reports values --> DM
CS -- parameters, changes --> VIEWS
VIEWS -- registers, answers writes --> DM
EXT -- registration, changes --> PRV
PRV -- registers, answers writes --> DM
DM --> CSMS
DM --> API
One model for OCPP 1.6 and OCPP 2.x¶
The device model backs configuration and telemetry of both protocol versions. OCPP 2.x addresses it directly with
GetVariables, SetVariables and GetBaseReport. OCPP 1.6 knows only configuration keys, so OCPPmulti maps
each key onto a component and variable: a built-in mapping for the standard keys, custom mappings from
Ocpp16KeyMappingsPath, and the OCPP16LegacyCtrlr component for keys without a standardized counterpart.
GetConfiguration and ChangeConfiguration read and write the mapped variables, whichever contributor owns
them; a variable without a mapping is invisible to an OCPP 1.6 CSMS. OCPP 1.6 has no variable monitoring, so
telemetry such as EVSE / Power reaches a 1.6 CSMS only through MeterValues. The ocpp interface
sees every variable in both modes.
Who contributes¶
Contributor |
Owner |
Brings |
Values live in |
|---|---|---|---|
Component configuration |
|
the components and variables defined in the JSON files under |
the device model database |
libocpp |
|
|
memory, computed by libocpp |
Components EVerest provides |
|
|
memory, reported by the module; DER |
EVerest module configuration views |
|
one component per EVerest module the OCPP module may read, one variable per configuration parameter |
the configuration service |
External providers |
|
their own components, vendor variables on standard components, and standard configuration variables the component configuration leaves out |
the provider; nothing on the EVerest side |
Custom configuration and telemetry¶
An integrator adds custom configuration and telemetry to the device model in one of two ways: in the component configuration, or through an external provider. They differ in who owns the value.
Component configuration |
External provider |
|
|---|---|---|
Owner of the value |
the OCPP module, in the device model database |
the integrator’s component |
Declared in |
the JSON files |
the provider’s registration |
Validated by |
the device model, against the declared characteristics |
the device model, then the provider itself |
Told about a write |
nobody; a client watches with |
the provider, which may reject it |
Telemetry |
as an interim until providers exist, declared for it; see below |
yes; the provider reports its values as they change |
Choose it for |
configuration the station is given, where type, range and enum checks are enough |
configuration the component validates, keeps or changes itself; telemetry; a standard variable the component configuration leaves out |
A custom variable is declared in exactly one of them.
Telemetry in the component configuration¶
Until external providers are available, an integrator’s own telemetry can be declared in the component
configuration and reported through the ocpp interface, from an EVerest module or a client of the
ocpp_consumer_API. This is supported as an interim; the variable moves to a provider once providers exist. The
component configuration is meant for configuration, so the variable has to be declared for the purpose:
mutabilityReadOnly: the CSMS cannot write the value, theocppinterface can.persistentfalse: otherwise every reported value is a database write. The value then lives in memory and, after a restart, is the value from the component configuration until the first report.No
minLimitormaxLimit, or limits that cover every value the source can report. A value outside them is rejected like a configuration write, and the variable keeps its last value, so a reading out of range, typically a fault, reaches neither the CSMS nor the monitors on the variable.supportsMonitoringtrueif the CSMS may monitor the variable.
For example, a coolant temperature in a custom component file:
{
"name": "CoolingCtrlr",
"type": "object",
"properties": {
"CoolantTemperature": {
"variable_name": "CoolantTemperature",
"characteristics": {
"supportsMonitoring": true,
"dataType": "decimal",
"unit": "Celsius"
},
"attributes": [
{
"type": "Actual",
"mutability": "ReadOnly",
"persistent": false,
"value": 0
}
],
"type": "number"
}
}
}
A new variable, or a change to its declaration, takes effect at the next start of the module.
The component configuration¶
The JSON files under DeviceModelConfigPath define the station as the integrator ships it: the standardized
controllers, the network connection slots, InternalCtrlr and any custom component. They are described in
Device model configuration via component configs.
At the first start the files seed the database. At every later start their structure is applied again, so a new
or changed component, variable or attribute reaches the database, while values written at runtime are kept. From
then on the database holds the values. The module needs no EVSE or Connector component configuration; they
are registered at runtime.
A few of these variables are maintained by libocpp rather than by the CSMS: OCPPCommCtrlr /
ActiveNetworkProfile and NetworkConfigurationPriority and SecurityCtrlr / SecurityProfile, which
follow the connection in use; OCPP16LegacyCtrlr / NumberOfConnectors and OCPPCommCtrlr /
FieldLength of the ISO 15118 certificate response, filled at every start; and AuthCacheCtrlr / Storage
and LocalAuthListCtrlr / Entries, whose maxLimit the integrator configures to bound the authorization
cache and the local list.
libocpp¶
libocpp registers AvailabilityState of the charging station, of every EVSE and of every connector under the owner
OCPP_STACK, each unless the component configuration defines it. The value comes from the same state machine
that drives StatusNotification, so GetVariables and StatusNotification always agree. The standardized
ChargingStation component configuration defines the charging station’s AvailabilityState, and component
configurations written for earlier versions may define those of the EVSEs and connectors; libocpp leaves such a
definition in place and writes its value in the same way. The OCPP 1.6 stack does not use them, so the OCPP 1.6
path skips the registration.
Components EVerest provides¶
The components that describe the station’s hardware and the connected EV are built from what the EVerest modules
report and registered under the owner EVEREST at every start. An EVSE that is added or removed shows up at
the next start without touching the database.
Component |
One per |
Variables |
|---|---|---|
|
EVSE |
|
|
connector |
|
|
EVSE |
|
|
EVSE with an ISO 15118 extension |
|
|
EVSE |
|
|
EVSE with a |
|
The values come from the EVSE manager, its power meter, the ISO 15118 extension and the grid_support device,
and the module reports them as they change. All variables are ReadOnly except Enabled of the DER
controllers, which the CSMS may write; it is the only persistent attribute of this group, so the value the CSMS
set survives a restart. Monitors the CSMS sets on any of these variables survive a restart as well.
EVerest module configuration views¶
The configuration of the other EVerest modules is visible in the device model under the owner EVEREST_CONFIG:
One component per module, named after the module type, with the module id as instance and the EVSE and connector taken from the module’s mapping:
EvseManagerwith instanceconnector_1on EVSE 1.One variable per configuration parameter, named like the parameter; a parameter of an implementation is prefixed with the implementation id.
Data type, unit, limits and mutability come from the manifest.
WriteOnlyparameters cannot be monitored, and reports leave out their values.The values stay in the configuration service, which keeps them across restarts.
Which modules are visible follows the access block of the OCPP module in the EVerest configuration: reading
needs read access to the module, writing additionally needs write access. A ReadOnly parameter cannot be
changed through OCPP.
A write the CSMS makes is forwarded to the configuration service, and its answer is the answer to the CSMS:
Accepted, Rejected, or RebootRequired for a parameter the module applies only at its next start. A
change made elsewhere, for example through the Configuration API, shows up in GetVariables and in variable
monitors right away. A change that the module applies only at its next start does not: until then,
GetVariables returns the value in effect.
External providers¶
An integrator can bring their own configuration and telemetry into the device model from outside the EVerest
process tree: a vendor controller with its settings, a display, a payment terminal, a cloud agent. The EVerest
interface ocpp_device_model_provider carries it, and the bridge module ocpp_device_model_provider_API
exposes it on the EVerest API, so a client needs no EVerest module of its own. Each provider is registered as an
owner of its own, EXT:<module_id>.
A provider hands OCPPmulti its registration: the complete set of components it owns, with characteristics,
attributes and current values. OCPPmulti asks for it at start and whenever the provider signals a change; a new
registration replaces the previous one. A write from the CSMS, already validated against the registered
characteristics, is handed to the provider, which answers Accepted, RebootRequired or Rejected. A
value the provider changes itself is reported to the device model like a value EVerest provides. Whether a
variable is only reported or also written follows the mutability the provider registers.
A provider owns its values, whatever persistent says; OCPPmulti stores nothing of them, so the provider keeps
them across its own restarts. Monitors the CSMS places on a provider’s variables are stored by OCPPmulti and apply
again when the provider registers at the next start.
A provider may register components of its own, such as VendorCtrlr / DisplayBrightness; vendor variables on
a standard component, such as a vendor variable on EVSE; and standard configuration variables the component
configuration leaves out, such as OCPPCommCtrlr / HeartbeatInterval. To hand such a variable to a provider,
the integrator places a component configuration of the same component without the variable under
component_config/custom, which replaces the standardized one; the variable’s monitors carry over to the
provider’s registration. A provider that registers a standard variable must use the data type the
standard defines, since libocpp reads it. A provider may not register what the component configuration defines,
libocpp writes from its own state or EVerest reports, such as AvailabilityState, SecurityCtrlr /
Identity, a network connection profile or EVSE / Power; such a variable is rejected and the rest of the
registration is applied.
Rules of composition¶
The device model applies the same few rules to every contributor:
One definition per variable. A variable is defined by the component configuration or by one runtime owner. A registration of a variable that the component configuration or another runtime owner defines is rejected, and the rest of the registration is applied. A component may combine both: the component configuration can add variables to
EVSEorConnector, as long as it leaves out those EVerest registers.Conflicts are errors. A variable defined twice is a conflict. OCPPmulti logs them at every start as one error that names each variable and what to remove from the component configuration. By default the station starts anyway, so that a station whose component configuration is outdated after an update stays reachable for the CSMS; with
FailOnDeviceModelConflictsthe module does not start.A variable can move from the component configuration to a registration. When an update removes a variable from the component configuration, or the whole file of its component, and a runtime owner registers it, its monitors carry over: the device model keeps them by name when the variable leaves the component configuration and applies them when the owner registers it. The value is not kept; the owner registers its own.
persistent describes the value, not where it is stored. For an owner that answers writes itself, the owner keeps the value; for every other owner, the device model stores a persistent attribute in its database.
A read returns the value in effect.
Acceptedstores the value in the device model, whoever owns the variable, so aGetVariablesafter aSetVariablesreturns the value the CSMS set. AfterRebootRequiredthe device model keeps the previous value: the owner holds the value written for the next start and registers with it then. OCPP 2.x leaves open what a read returns until then; B10.FR.01 allows either answer for aNetworkConfigurationPrioritychange that applies after a reboot.libocpp writes what it owns. libocpp sets a variable it registered or one of the component configuration variables it maintains. A write of its own to a variable an external provider took over, such as the heartbeat interval from the
BootNotificationresponse, reaches the provider like a CSMS write.Every write reaches the owner. The CSMS writes across all contributors; that is what OCPP is for. The
ocppinterface, and with it theocpp_consumer_APImodule, is the local channel, the integrator’s own code that OCPPmulti trusts: it writesReadOnlyvariables of the component configuration, which the integrator maintains that way, and writes a registered variable like the CSMS does, through its owner and only when it isReadWrite. AReadOnlyregistered variable is a value its owner reports, so a write to it is rejected: the modules report the values they provide, and an external provider changes its own values.
Startup¶
The device model is complete before the charge point reports it for the first time. On the OCPP 2.x and the OCPP 1.6 path alike, OCPPmulti
collects what the connected modules report and asks every external provider for its registration;
opens the device model database and applies the component configuration;
registers the components EVerest provides, the EVerest module configuration views and the external providers;
registers the availability states (OCPP 2.x only);
reports the conflicts between the component configuration and the registrations, and stops if
FailOnDeviceModelConflictsis set;constructs the charge point, which checks the composed model for completeness, and connects to the CSMS.
External providers are up when OCPPmulti starts; the stack relies on that. A registration a provider changes at
runtime is applied live: visible to GetVariables at once, and to the CSMS with its next GetBaseReport.
Reads, writes and changes¶
Reads are served from memory, on every channel: the CSMS, the ocpp interface and with it the
ocpp_consumer_API module see the complete composed model. A write goes to whoever owns the variable, and every
owner has its own way of reporting a change. The sequences below show both, per contributor. Each one ends the
same way: the device model updates memory and evaluates the monitors of the variable, which is where a
NotifyEvent originates.
Component configuration¶
sequenceDiagram
participant CSMS
participant API as ocpp interface
participant LIB as libocpp
participant DM as device model
participant DB as database
Note over CSMS,DB: Write by the CSMS
CSMS->>DM: SetVariables HeartbeatInterval
DM->>DM: validate, reject a ReadOnly attribute
DM->>DB: store, if the attribute is persistent
DM->>DM: update memory, evaluate monitors
DM-->>CSMS: Accepted
Note over CSMS,DB: Write through the ocpp interface
API->>DM: set_variables ChargePointModel, a ReadOnly variable
DM->>DB: store, if the attribute is persistent
DM->>DM: update memory, evaluate monitors
DM-->>API: Accepted
Note over CSMS,DB: Write by libocpp
LIB->>DM: ActiveNetworkProfile changed
DM->>DB: store, if the attribute is persistent
DM->>DM: update memory, evaluate monitors
The database is written only for persistent attributes, which component configuration attributes are unless the
JSON says otherwise. The ocpp interface is the local channel and also writes ReadOnly variables, since
ReadOnly models the CSMS contract; see Configuration access.
EVerest module configuration views¶
sequenceDiagram
participant CSMS
participant DM as device model
participant V as configuration views
participant CS as configuration service
participant CA as Configuration API
Note over CSMS,CA: Write by the CSMS
CSMS->>DM: SetVariables EvseManager(connector_1).session_logging = false
DM->>DM: validate
DM->>V: write
V->>CS: set parameter
CS-->>V: RebootRequired
V-->>DM: RebootRequired
DM->>DM: keep memory
DM-->>CSMS: RebootRequired
CSMS->>DM: GetVariables EvseManager(connector_1).session_logging
DM-->>CSMS: true, the value the module runs with
Note over CSMS,CA: Read through the Configuration API until the restart
CA->>CS: get session_logging
CS-->>CA: true, the value the module runs with
Note over CSMS,CA: Change through the Configuration API
CA->>CS: set session_logging = true
CS-)V: change notification
V->>DM: value changed
DM->>DM: update memory, evaluate monitors
Memory changes only when the configuration service answered Accepted. After RebootRequired the module keeps
running with its previous value until the next start, and so does the device model: the CSMS reads the previous value
until the views register the new one at the next start, like for every other owner. Until then the Configuration API
answers a read with the value the module runs with as well, unless the request sets force_read_from_db. A change
through the Configuration API that the module applies at once is reported to the device model when the configuration
service delivers it; one that waits for the next start is not. A write from the ocpp interface to a ReadWrite
view reaches the configuration service like a write from the CSMS.
Known gap
If the CSMS and a second writer, such as the Configuration API, change the same parameter within milliseconds, the device model can keep the value of the CSMS while the module runs with the value of the second writer. The CSMS then reads the outdated value, and monitors are evaluated against it, until the parameter changes again or OCPPmulti restarts.
The configuration service applies both changes in order, but OCPPmulti handles the answer to its own write and the notification of the other change on different threads, and nothing orders the two when they reach the device model.
Components EVerest provides¶
sequenceDiagram
participant PM as power meter
participant M as OCPPmulti
participant DM as device model
participant DB as database
participant CSMS
Note over PM,CSMS: Value reported by the module
PM-)M: powermeter
M->>DM: EVSE.Power changed
DM->>DM: update memory, evaluate monitors
DM-)CSMS: NotifyEvent, if a monitor triggers
Note over PM,CSMS: Write by the CSMS
CSMS->>DM: SetVariables DCDERCtrlr.Enabled = false
DM->>DM: validate
DM->>DB: store, the attribute is persistent
DM->>DM: update memory, evaluate monitors
DM-->>CSMS: Accepted
The module reports every value it provides, the DER capability included. A reported value must fit the data type
and the value list of the variable; limits bound what the CSMS may set, not what the module reports. DER
Enabled is the one variable of this group the CSMS, or the ocpp interface, writes, and the device model
stores it. A write to any other variable of this group is rejected, from the ocpp interface as well, since the
module reports them.
External providers¶
sequenceDiagram
participant CSMS
participant DM as device model
participant BR as provider bridge
participant C as client
Note over CSMS,C: Write by the CSMS
CSMS->>DM: SetVariables VendorCtrlr.DisplayBrightness = 50
DM->>DM: validate against the registered characteristics
DM->>BR: set_value
BR->>C: set_value
C-->>BR: Accepted
BR-->>DM: Accepted
DM->>DM: update memory, evaluate monitors
DM-->>CSMS: Accepted
Note over CSMS,C: Value changed by the client
C-)BR: value_changed DisplayBrightness = 65
BR->>DM: value changed
DM->>DM: update memory, evaluate monitors
DM-)CSMS: NotifyEvent, if a monitor triggers
The CSMS waits on the same call as the client, so a client that does not answer in time gets Rejected on its
behalf. A write from the ocpp interface to a ReadWrite variable of a provider reaches the provider like a
write from the CSMS.
What the database stores¶
The database at DeviceModelDatabasePath keeps three things:
the component configuration: its structure and the values of its persistent attributes;
the monitors, those the CSMS set and the hardwired and preconfigured ones, keyed by component and variable name, for every variable whoever owns it;
the values of persistent attributes of registered variables, which today is DER
Enabledonly.
Nothing is kept for the EVerest module configuration views or for external providers: the configuration service and the providers hold their values.
Monitors belong to OCPP, not to the owner of the variable, and are stored by name so that they outlive the
registration that brought the variable. Until the owner registers, its variables are not part of the model and
their monitors are kept, invisible to the CSMS, and active again with the same id once the owner registers the
variable. A monitor whose owner registers without the variable, or whose variable no longer supports monitoring, is
removed. The DER Enabled value the CSMS set follows the same rule. The removal happens at every start, after
EVerest registered its components, so removing an EVSE or a grid_support connection, or switching an EVSE between
AC and DC, removes the monitors and the Enabled value of the variables that go away.
Some variables are registered in OCPP 2.x mode only: the DER controllers, since DER is not supported in OCPP 1.6 mode,
and the AvailabilityState of the EVSEs and connectors, which libocpp registers for its OCPP 2.x charge point
unless the component configuration defines it. A start in OCPP 1.6 mode removes the monitors and stored values a CSMS
set on them in OCPP 2.x mode. At the next start in OCPP 2.x mode, DER Enabled is back at its default true and
the CSMS has to set it and the monitors again; the DER controls the CSMS set before are kept. OCPP does not foresee a
downgrade from OCPP 2.x to OCPP 1.6; the module supports it, but does not keep this state across it.
Earlier versions kept the components EVerest provides in a second database, EverestDeviceModelDatabasePath
(deprecated). At the first start the module takes it over: the DER Enabled values the CSMS set are imported into
the device model database and the file is renamed to *.migrated. The steps are in
Migrate to the Combined OCPP Module.
Monitors¶
A monitor watches one variable and sends a NotifyEvent to the CSMS when the variable crosses a threshold,
changes by more than a delta, or periodically. Only a variable with supportsMonitoring can have monitors. There
are three kinds:
custom monitors, which the CSMS sets with SetVariableMonitoring and may change and clear;
preconfigured monitors, which the integrator declares and the CSMS may change;
hardwired monitors, which the integrator declares and the CSMS can neither change nor clear.
Monitoring is OCPP 2.x only. These variables control it:
Variable |
Effect |
|---|---|
|
Switches monitoring on; |
|
The monitoring base the CSMS selected with SetMonitoringBase: |
|
The severity the CSMS selected with SetMonitoringLevel: only events of monitors of this severity or more severe (lower number) are sent (N05.FR.03). |
|
While offline, events of monitors of this severity or more severe are queued and sent once online (N07.FR.04). |
|
How often periodic monitors are evaluated, in seconds. |
Hardwired and preconfigured monitors¶
Hardwired and preconfigured monitors are declared where the variable is defined. For a telemetry variable they are its default alarms.
A variable of the component configuration lists them in a
monitorsarray next to itsattributes.A variable registered at runtime, such as one of an external provider, lists them in
RegisteredVariable::monitorswith the same fields.
The components EVerest provides and the module configuration views declare none.
For example, two hardwired thresholds and a preconfigured delta monitor on EVSE / Power in a component
configuration:
"monitors": [
{
"value": 21950,
"severity": 1,
"transaction": false,
"type": "UpperThreshold",
"config_type": "HardWiredMonitor"
},
{
"value": 100,
"severity": 1,
"transaction": false,
"type": "LowerThreshold",
"config_type": "HardWiredMonitor"
},
{
"value": 100,
"severity": 1,
"transaction": false,
"type": "Delta",
"reference_value": "10700",
"config_type": "PreconfiguredMonitor"
}
]
type is a monitor type of OCPP, for example UpperThreshold, Delta or Periodic;
severity is 0 (most severe) to 9; transaction limits the monitor to a running transaction. A delta monitor of
the component configuration needs a reference_value: it is the starting point of the first delta and is used only
when the monitor is first stored; afterwards the stored reference value, which follows every event sent, is kept. A
registered monitor needs none: a new delta monitor starts from the current value of the variable. A monitor on a
variable without supportsMonitoring stops the start when it is in the component configuration. A registered
monitor that does not fit the variable, a threshold outside its limits for example, or that is declared as
CustomMonitor, is ignored with a warning.
At a start and at a new registration¶
The database keeps every monitor by component and variable name, so monitors outlast restarts and re-registrations. A declared monitor is matched to the stored monitor of the same variable with the same type and severity (N04.FR.10); the matched monitor keeps its id and its reference value.
The monitors of the component configuration are applied at every start. They are compared only with the stored hardwired and preconfigured monitors: a matched monitor takes the declared value, transaction flag and kind when they differ, a hardwired or preconfigured monitor that is no longer declared is removed, and an unmatched one is added. Custom monitors are left alone.
The monitors of a registration are applied whenever its owner registers, at every start and again whenever it registers anew. A stored hardwired or preconfigured monitor the registration no longer declares is removed, and so is any monitor, custom ones included, that does not fit the variable as registered. A matched stored monitor is handled by its kind:
Stored |
Declared |
Result |
|---|---|---|
hardwired or preconfigured |
hardwired or preconfigured |
Takes the declared value, kind and transaction flag; written only when something differs. |
custom |
preconfigured |
Kept: a preconfigured monitor the CSMS changed is stored as custom (N04.FR.15) and belongs to the CSMS. |
custom |
hardwired |
Replaced by the hardwired monitor under the same id, with a warning in the log. |
A variable that its owner no longer registers loses all its monitors, see What the database stores.
What the CSMS can change¶
SetVariableMonitoring adds custom monitors and changes a monitor by its id. A preconfigured monitor the CSMS changes becomes custom until a SetMonitoringBase resets it (N04.FR.15); a hardwired monitor cannot be changed (N04.FR.18).
ClearVariableMonitoring clears custom monitors; for a hardwired or preconfigured monitor it answers
Rejected(N06.FR.03).SetMonitoringBase selects the monitoring base (N03).
Allactivates the preconfigured monitors and keeps the custom ones.FactoryDefaultdeletes the custom monitors, changed preconfigured ones included, and activates the preconfigured monitors.HardWiredOnlydeletes the custom monitors and deactivates the preconfigured ones. The CSMS can add custom monitors on top of every base.
Known deviations from OCPP¶
libocpp deviates from OCPP in these points:
The monitoring base acts as a filter: under
FactoryDefaultno custom monitor is evaluated, underHardWiredOnlyonly hardwired monitors are, so a custom monitor the CSMS adds afterwards never triggers (#1994).A preconfigured monitor the CSMS changed does not come back when SetMonitoringBase deletes the custom monitors, only at the next start or, for a registered variable, at the next registration (N03.FR.03, N03.FR.04; #1994).
SetVariableMonitoring with the id of a hardwired monitor is accepted and stores the changed monitor as custom (N04.FR.18; #3399). A registration that declares the hardwired monitor replaces it again.
A variable can have two monitors of the same type and severity (N04.FR.10; #3400): the component configuration adds a declared monitor again at the next start next to the custom monitor the CSMS changed it into, and a SetVariableMonitoring with an id is not checked for duplicates.
Events queued while offline are sent once online also when their severity is above