power_supply_DC_API¶
API for DC power supplies
Handwritten Documentation¶
The complete API specification can be found in the
docs/source/reference/EVerest_API/power_supply_DC_API.yaml
file in the source repository, or in the AsyncAPI HTML documentation automatically generated from it.
Setpoints below the minimum current¶
When the EV or an energy limit asks for less than the minimum current offered
to the EV, EVerest sends a current below min_export_current_A or
min_import_current_A, usually 0 A. This means: deliver no current (0 A,
+/- 0.15 A, IEC 61851-23:2023 CC.5.5.2). Do not raise it to the minimum. If the
hardware cannot regulate to 0 A, switch its output off, keep the mode, and switch
it on again when a current at or above the minimum is requested.
During cable check and precharge, EVerest never sends less than the minimum.
Auto-Generated Reference¶
Module Configuration¶
cfg_communication_check_to_s: integer <optional>
default: 5
Maximum time between two communication check events. Values <= 0 disables communication checks.
cfg_heartbeat_interval_ms: integer <optional>
default: 1000
Interval between two heartbeat messages send by the API. Values <= 0 disable heartbeat.
Provides¶
main: power_supply_DC
Allows EVerest to control a DC power supply device via API clients.