13.3.21. sunspec_ac_meter

sunspec ac powermeter types

Result:object
Measured dataset
properties:
timestamp:integer <required>
Timestamp of measurement
ID:integer <optional>
ID Model ID uinteger no 203 SunSpec Model AC Meter
L:integer <optional>
L Model Payload Length uinteger no 105 Without the fields ‘Model ID’ and ‘Length of payload.
A:integer <optional>
A Amps int16 A no
AphA:integer <optional>
AphA Amps PhaseA int16 A no
AphB:integer <optional>
AphB Amps PhaseB int16 A no
AphC:integer <optional>
AphC Amps PhaseC int16 A no
A_SF:integer <optional>
A_SF integer no
PhVphA:integer <optional>
PhVphA Phase Voltage AN int16 V no
PhVphB:integer <optional>
PhVphB Phase Voltage BN int16 V no
PhVphC:integer <optional>
PhVphC Phase Voltage CN int16 V no
V_SF:integer <optional>
V_SF sunssf no
Hz:integer <optional>
Hz Hz int16 Hz no
Hz_SF:integer <optional>
Hz_SF sunssf no
W:integer <optional>
W Watts int16 W no
WphA:integer <optional>
WphA Watts phase A int16 W no
WphB:integer <optional>
WphB Watts phase B int16 W no
WphC:integer <optional>
WphC Watts phase C int16 W no
W_SF:integer <optional>
W_SF sunssf no
VA:integer <optional>
VA VA int16 VA no
VAphA:integer <optional>
VAphA VA phase A int16 VA no
VAphB:integer <optional>
VAphB VA phase B int16 VA no
VAphC:integer <optional>
VAphC VA phase C int16 VA no
VA_SF:integer <optional>
VA_SF integer no
VAR:integer <optional>
VAR VAR int16 var no
VARphA:integer <optional>
VARphA VAR phase A int16 var no
VARphB:integer <optional>
VARphB VAR phase B int16 var no
VARphC:integer <optional>
VARphC VAR phase C int16 var no
VAR_SF:integer <optional>
VAR_SF sunssf no
PFphA:integer <optional>
PFphA PF phase A int16 Pct no
PFphB:integer <optional>
PFphB PF phase B int16 Pct no
PFphC:integer <optional>
PFphC PF phase C int16 Pct no
PF_SF:integer <optional>
PF_SF sunssf no
TotWhIm:integer <optional>
TotWhIm p Total Watt-hours Imported acc32 Wh no
TotWh_SF:integer <optional>
TotWh_SF sunssf no
Evt:integer <optional>
Evt Events bitfield32 no See chapter 17.5 Event flags of critical events of counter and communication module. A problem exists if this value is different from zero.