ocpp_consumer_API

version 1.1.0AsyncAPI 3.0.0 content type application/jsonlicense Apache-2.0EVerestOCPP

EVerest API definition for ocpp (consumer)

API for EVerest API clients implementing occp / ocpp_data_transfer (consumer).

Specification: ocpp_consumer_API.yaml · pionix:de:everest:ocpp_consumer_API

send the client publishes, EVerest consumes (18) receive EVerest publishes, the client consumes (25)

Servers

default mqtt

default local MQTT

Host
localhost:1883
Topic prefix
everest_api/1/ocpp_consumer/{module_id}
{module_id}

The ID of the module as defined in the EVerest config file

Operations

Client to EVerest

send_reply_data_transfer_incoming

send Response for outgoing OCPP data transfer request
Topic
Dynamic: the replyTo address from the request's headers. Answers receive_request_data_transfer_incoming.
Message Reply to data transfer request application/json

Message send_reply_data_transfer_incoming

Reply to the request to transfer data

Payload

object DataTransferResponse

Type for data transfer response provided by OCPP

Definition of DataTransferResponse

Example

Example 1
{
  "status": "Accepted",
  "data": "string",
  "custom_data": {
    "vendor_id": "string",
    "data": "string"
  }
}

send_request_data_transfer_outgoing

send Performs an outgoing OCPP data transfer request and returns the response
Topic
everest_api/1/ocpp_consumer/{module_id}/m2e/data_transfer_outgoing
Reply
Sent to $message.header#/replyTo as receive_reply_data_transfer_outgoing.

Direction: Module to EVerest

Message Request data transfer application/json

Message send_request_data_transfer_outgoing

Request data transfer.

Payload

object
  • headersobject
    • replyTostring

      Address to send the response to. Omit it to discard the response. An invalid address, see the EVerest API explanation, rejects the request.

      min length 1
  • payloadobject requiredDataTransferRequest

    Type for data transfer request provided by OCPP

    Definition of DataTransferRequest

Example

Example 1
{
  "headers": {
    "replyTo": "everest_api/1/{interface_type}/{module_id}/e2m/{operation_name}/{uuid}"
  },
  "payload": {
    "vendor_id": "string",
    "message_id": "string",
    "data": "string",
    "custom_data": {
      "vendor_id": "string",
      "data": "string"
    }
  }
}

send_request_get_variables

send Send request to transmit the requested variables
Topic
everest_api/1/ocpp_consumer/{module_id}/m2e/get_variables
Reply
Sent to $message.header#/replyTo as receive_reply_get_variables.

Direction: Module to EVerest

Message Request variables application/json

Message send_request_get_variables

Request the variables.

Reads variables using canonical component/variable addressing (e.g. component OCPPCommCtrlr, variable HeartbeatInterval), identical for OCPP 1.6 and 2.x. An empty component.name marks the deprecated OCPP 1.6 legacy key form (variable.name = configuration key); it is only accepted while OCPP 1.6 is active and will be removed per the deprecation policy. A non-empty component.name is never reinterpreted as a configuration key. Each result echoes the requested component_variable and carries a status.

See the OCPPmulti module documentation ("Configuration access" and "Migration from OCPP 1.6 key addressing") for examples and the migration guide.

Payload

object
  • headersobject
    • replyTostring

      Address to send the response to. Omit it to discard the response. An invalid address, see the EVerest API explanation, rejects the request.

      min length 1
  • payloadobject requiredGetVariableRequestList

    List of GetVariableRequest values

    Definition of GetVariableRequestList

Example

Example 1
{
  "headers": {
    "replyTo": "everest_api/1/{interface_type}/{module_id}/e2m/{operation_name}/{uuid}"
  },
  "payload": {
    "items": [
      {
        "component_variable": {
          "component": {
            "name": "string",
            "instance": "string",
            "evse": {
              "id": 1,
              "connector_id": 1
            }
          },
          "variable": {
            "name": "string",
            "instance": "string"
          }
        },
        "attribute_type": "Actual"
      }
    ]
  }
}

send_request_set_variables

send Send request to set the listed variables
Topic
everest_api/1/ocpp_consumer/{module_id}/m2e/set_variables
Reply
Sent to $message.header#/replyTo as receive_reply_set_variables.

Direction: Module to EVerest

Message Request set variables application/json

Message send_request_set_variables

Request setting the variables.

Writes variables using the same canonical component/variable addressing as get_variables, identical for OCPP 1.6 and 2.x; the empty-component OCPP 1.6 legacy key form is deprecated and scheduled for removal. Connection-configuration writes (component NetworkConfiguration with the profile slot number as component instance, and the OCPPCommCtrlr/NetworkConfigurationPriority selector) return RebootRequired: the value is validated and persisted immediately and takes effect on the next (re)connect or reboot.

See the OCPPmulti module documentation ("Configuration access" and "Migration from OCPP 1.6 key addressing") for examples and the migration guide.

Payload

object
  • headersobject
    • replyTostring

      Address to send the response to. Omit it to discard the response. An invalid address, see the EVerest API explanation, rejects the request.

      min length 1
  • payloadobject requiredSetVariablesArgs

    Arguments for set_variables

    Definition of SetVariablesArgs

Example

Example 1
{
  "headers": {
    "replyTo": "everest_api/1/{interface_type}/{module_id}/e2m/{operation_name}/{uuid}"
  },
  "payload": {
    "variables": {
      "items": [
        {
          "component_variable": {
            "component": {
              "name": "string",
              "instance": "string",
              "evse": {
                "id": 1,
                "connector_id": 1
              }
            },
            "variable": {
              "name": "string",
              "instance": "string"
            }
          },
          "value": "string",
          "attribute_type": "Actual"
        }
      ]
    },
    "source": "string"
  }
}

send_request_monitor_variables

send Send request to monitor the requested variables
Topic
everest_api/1/ocpp_consumer/{module_id}/m2e/monitor_variables

Direction: Module to EVerest

Message Monitor variables application/json

Message send_request_monitor_variables

Monitor the variables.

Command to start monitoring the given ComponentVariable(s), using the same canonical component/variable addressing as get_variables, identical for OCPP 1.6 and 2.x; the empty-component OCPP 1.6 legacy key form is deprecated. Changes to monitored variables are published on the event_data channel and echo the addressing form used at registration. Consecutive calls of this operation will not override but extend the existing monitors.

See the OCPPmulti module documentation ("Configuration access" and "Migration from OCPP 1.6 key addressing") for examples and the migration guide.

Payload

object MonitorVariableRequestList

List of MonitorVariableRequest values

Definition of MonitorVariableRequestList

Example

Example 1
{
  "items": [
    {
      "component": {
        "name": "string",
        "instance": "string",
        "evse": {
          "id": 1,
          "connector_id": 1
        }
      },
      "variable": {
        "name": "string",
        "instance": "string"
      }
    }
  ]
}

send_request_monitor_and_get_variables

send Send request to monitor the requested variables and read their current values
Topic
everest_api/1/ocpp_consumer/{module_id}/m2e/monitor_and_get_variables
Reply
Sent to $message.header#/replyTo as receive_reply_monitor_and_get_variables.

Direction: Module to EVerest

Message Monitor variables and read their current values application/json

Message send_request_monitor_and_get_variables

Monitor the variables and receive their current values in the reply.

Combination of monitor_variables and get_variables in one call: starts monitoring the given ComponentVariable(s) exactly like monitor_variables, using the same canonical component/variable addressing as get_variables, identical for OCPP 1.6 and 2.x; the empty-component OCPP 1.6 legacy key form is deprecated. Changes to monitored variables are published on the event_data channel and echo the addressing form used at registration. Consecutive calls of this operation will not override but extend the existing monitors. Additionally the reply contains the current (Actual) value of every requested variable, with the same order, addressing echo and status semantics as get_variables. The monitors are registered before the values are read, so no update can be lost: every change from registration on is published on the event_data channel, and the reply reflects each variable's state at some point after registration. The reply is not ordered against the event stream, however: a change around the call may be reported both in the reply and as an event, and an event may arrive before the reply does. Treat event_data as authoritative for a variable once its first event arrived; use the reply value only until then. This allows registering monitors at startup and obtaining the initial values in a single call without losing an update between the first read and the monitor registration.

See the OCPPmulti module documentation ("Configuration access" and "Migration from OCPP 1.6 key addressing") for examples and the migration guide.

Payload

object

Example

Example 1
{
  "headers": {
    "replyTo": "everest_api/1/{interface_type}/{module_id}/e2m/{operation_name}/{uuid}"
  },
  "payload": {
    "items": [
      {
        "component": {
          "name": "string",
          "instance": "string",
          "evse": {
            "id": 1,
            "connector_id": 1
          }
        },
        "variable": {
          "name": "string",
          "instance": "string"
        }
      }
    ]
  }
}

send_request_change_availability

send Send request to change the availability
Topic
everest_api/1/ocpp_consumer/{module_id}/m2e/change_availability
Reply
Sent to $message.header#/replyTo as receive_reply_change_availability.

Direction: Module to EVerest

Message Request change availability application/json

Message send_request_change_availability

Request to change the availability of the Charging Station / an EVSE / a Connector.

Allows to send a ChangeAvailabilityRequest internally (as can be done by the CSMS).

Payload

object
  • headersobject
    • replyTostring

      Address to send the response to. Omit it to discard the response. An invalid address, see the EVerest API explanation, rejects the request.

      min length 1
  • payloadobject requiredChangeAvailabilityRequest

    Request type to change the availability of the Charging Station/ an EVSE / a Connector.

    Definition of ChangeAvailabilityRequest

Example

Example 1
{
  "headers": {
    "replyTo": "everest_api/1/{interface_type}/{module_id}/e2m/{operation_name}/{uuid}"
  },
  "payload": {
    "operational_status": "Inoperative",
    "evse": {
      "id": 1,
      "connector_id": 1
    }
  }
}

send_request_security_event

send Send request to trigger a security event
Topic
everest_api/1/ocpp_consumer/{module_id}/m2e/security_event

Direction: Module to EVerest

Message Trigger security event application/json

Message send_request_security_event

Trigger a security event.

Triggers a SecurityEventNotification.req at the CSMS if it is deemed critical, either by setting the flag in this event or if absent automatically by libocpp

Payload

object SecurityEvent

Type for a security event

Definition of SecurityEvent

Example

Example 1
{
  "type": "string",
  "info": "string",
  "critical": true,
  "timestamp": "2026-07-30T12:00:00Z"
}

send_request_get_ocpp_transaction_event

send Request current ocpp transaction event
Topic
everest_api/1/ocpp_consumer/{module_id}/m2e/ocpp_transaction_event/get
Reply
Sent to $message.header#/replyTo as receive_reply_get_ocpp_transaction_event.

Request the most recently published (latched) ocpp transaction event. The reply will be sent to the replyTo address specified in the message headers. If no latched value is available yet, a null payload will be sent.

Message Request current ocpp transaction event application/json

Message send_request_get_ocpp_transaction_event

Request the most recently published (latched) ocpp transaction event.

Payload

object
  • headersobject
    • replyTostring

      Address to send the response to. Omit it to discard the response. An invalid address, see the EVerest API explanation, rejects the request.

      min length 1

Example

Example 1
{
  "headers": {
    "replyTo": "everest_api/1/{interface_type}/{module_id}/e2m/{operation_name}/{uuid}"
  }
}

send_request_get_security_event

send Request current security event
Topic
everest_api/1/ocpp_consumer/{module_id}/m2e/security_event/get
Reply
Sent to $message.header#/replyTo as receive_reply_get_security_event.

Request the most recently published (latched) security event. The reply will be sent to the replyTo address specified in the message headers. If no latched value is available yet, a null payload will be sent.

Message Request current security event application/json

Message send_request_get_security_event

Request the most recently published (latched) security event.

Payload

object
  • headersobject
    • replyTostring

      Address to send the response to. Omit it to discard the response. An invalid address, see the EVerest API explanation, rejects the request.

      min length 1

Example

Example 1
{
  "headers": {
    "replyTo": "everest_api/1/{interface_type}/{module_id}/e2m/{operation_name}/{uuid}"
  }
}

send_request_get_boot_notification_response

send Request current boot notification response
Topic
everest_api/1/ocpp_consumer/{module_id}/m2e/boot_notification_response/get
Reply
Sent to $message.header#/replyTo as receive_reply_get_boot_notification_response.

Request the most recently published (latched) boot notification response. The reply will be sent to the replyTo address specified in the message headers. If no latched value is available yet, a null payload will be sent.

Message Request current boot notification response application/json

Message send_request_get_boot_notification_response

Request the most recently published (latched) boot notification response.

Payload

object
  • headersobject
    • replyTostring

      Address to send the response to. Omit it to discard the response. An invalid address, see the EVerest API explanation, rejects the request.

      min length 1

Example

Example 1
{
  "headers": {
    "replyTo": "everest_api/1/{interface_type}/{module_id}/e2m/{operation_name}/{uuid}"
  }
}

send_request_get_event_data

send Request current event data
Topic
everest_api/1/ocpp_consumer/{module_id}/m2e/event_data/get
Reply
Sent to $message.header#/replyTo as receive_reply_get_event_data.

Request the most recently published (latched) event data. The reply will be sent to the replyTo address specified in the message headers. If no latched value is available yet, a null payload will be sent.

Message Request current event data application/json

Message send_request_get_event_data

Request the most recently published (latched) event data.

Payload

object
  • headersobject
    • replyTostring

      Address to send the response to. Omit it to discard the response. An invalid address, see the EVerest API explanation, rejects the request.

      min length 1

Example

Example 1
{
  "headers": {
    "replyTo": "everest_api/1/{interface_type}/{module_id}/e2m/{operation_name}/{uuid}"
  }
}

send_request_get_is_connected

send Request current Is Connected
Topic
everest_api/1/ocpp_consumer/{module_id}/m2e/is_connected/get
Reply
Sent to $message.header#/replyTo as receive_reply_get_is_connected.

Deprecated: use send_request_get_connection_status instead. Request the most recently published (latched) Is Connected. The reply will be sent to the replyTo address specified in the message headers. If no latched value is available yet, a null payload will be sent.

Message Request current Is Connected application/json

Message send_request_get_is_connected

Deprecated: use send_request_get_connection_status instead. Request the most recently published (latched) Is Connected.

Payload

object
  • headersobject
    • replyTostring

      Address to send the response to. Omit it to discard the response. An invalid address, see the EVerest API explanation, rejects the request.

      min length 1

Example

Example 1
{
  "headers": {
    "replyTo": "everest_api/1/{interface_type}/{module_id}/e2m/{operation_name}/{uuid}"
  }
}

send_request_get_connection_status

send Request current Connection Status
Topic
everest_api/1/ocpp_consumer/{module_id}/m2e/connection_status/get
Reply
Sent to $message.header#/replyTo as receive_reply_get_connection_status.

Request the most recently published (latched) Connection Status. The reply will be sent to the replyTo address specified in the message headers. If no latched value is available yet, a null payload will be sent.

Message Request current Connection Status application/json

Message send_request_get_connection_status

Request the most recently published (latched) Connection Status.

Payload

object
  • headersobject
    • replyTostring

      Address to send the response to. Omit it to discard the response. An invalid address, see the EVerest API explanation, rejects the request.

      min length 1

Example

Example 1
{
  "headers": {
    "replyTo": "everest_api/1/{interface_type}/{module_id}/e2m/{operation_name}/{uuid}"
  }
}

send_request_get_implementation_ready

send Request current Implementation Ready
Topic
everest_api/1/ocpp_consumer/{module_id}/m2e/implementation_ready/get
Reply
Sent to $message.header#/replyTo as receive_reply_get_implementation_ready.

Request the most recently published (latched) Implementation Ready. The reply will be sent to the replyTo address specified in the message headers. The bridge seeds this value with false at startup, so a reply of null only occurs if latching is disabled for this module.

Message Request current Implementation Ready application/json

Message send_request_get_implementation_ready

Request the most recently published (latched) Implementation Ready.

Payload

object
  • headersobject
    • replyTostring

      Address to send the response to. Omit it to discard the response. An invalid address, see the EVerest API explanation, rejects the request.

      min length 1

Example

Example 1
{
  "headers": {
    "replyTo": "everest_api/1/{interface_type}/{module_id}/e2m/{operation_name}/{uuid}"
  }
}

send_request_get_charging_schedules

send Request current Charging Schedules
Topic
everest_api/1/ocpp_consumer/{module_id}/m2e/charging_schedules/get
Reply
Sent to $message.header#/replyTo as receive_reply_get_charging_schedules.

Request the most recently published (latched) Charging Schedules. The reply will be sent to the replyTo address specified in the message headers. If no latched value is available yet, a null payload will be sent.

Message Request current Charging Schedules application/json

Message send_request_get_charging_schedules

Request the most recently published (latched) Charging Schedules.

Payload

object
  • headersobject
    • replyTostring

      Address to send the response to. Omit it to discard the response. An invalid address, see the EVerest API explanation, rejects the request.

      min length 1

Example

Example 1
{
  "headers": {
    "replyTo": "everest_api/1/{interface_type}/{module_id}/e2m/{operation_name}/{uuid}"
  }
}

send_request_get_ocpp_message

send Request current ocpp message
Topic
everest_api/1/ocpp_consumer/{module_id}/m2e/ocpp_message/get
Reply
Sent to $message.header#/replyTo as receive_reply_get_ocpp_message.

Request the most recently published (latched) ocpp message. The reply will be sent to the replyTo address specified in the message headers. If no latched value is available yet, a null payload will be sent.

Message Request current ocpp message application/json

Message send_request_get_ocpp_message

Request the most recently published (latched) ocpp message.

Payload

object
  • headersobject
    • replyTostring

      Address to send the response to. Omit it to discard the response. An invalid address, see the EVerest API explanation, rejects the request.

      min length 1

Example

Example 1
{
  "headers": {
    "replyTo": "everest_api/1/{interface_type}/{module_id}/e2m/{operation_name}/{uuid}"
  }
}

send_communication_check

send Send communication check
Topic
everest_api/1/ocpp_consumer/{module_id}/m2e/communication_check
Message Send communication check application/json

Message send_communication_check

Signal to EVerest that communication is good or check shall be stopped

Payload

Send true at least every cfg_communication_check_to_s seconds to signal that the client is alive, otherwise EVerest raises a CommunicationFault, which the next message clears. Send false to stop the check until the module restarts.

Example

Example 1
true

EVerest to client

receive_request_data_transfer_incoming

receive Performs an incoming OCPP data transfer request and returns the response
Topic
everest_api/1/ocpp_consumer/{module_id}/e2m/data_transfer_incoming
Reply
Sent to $message.header#/replyTo as send_reply_data_transfer_incoming.

Direction: EVerest to Module

Message Request data transfer application/json

Message receive_request_data_transfer_incoming

Request data transfer.

Payload

object

Example

Minimal payload generated from the schema generated
{
  "headers": {
    "replyTo": "string"
  },
  "payload": {
    "vendor_id": "string"
  }
}

receive_reply_data_transfer_outgoing

receive Response for outgoing OCPP data transfer request
Topic
Dynamic: the replyTo address from the request's headers. Answers send_request_data_transfer_outgoing.
Message Reply to data transfer request application/json

Message receive_reply_data_transfer_outgoing

Reply to the request to transfer data

Payload

object DataTransferResponse

Type for data transfer response provided by OCPP

Definition of DataTransferResponse

Example

Minimal payload generated from the schema generated
{
  "status": "Accepted"
}

receive_reply_get_variables

receive Receive response with the requested variables
Topic
Dynamic: the replyTo address from the request's headers. Answers send_request_get_variables.
Message Request variables application/json

Message receive_reply_get_variables

Reply to the request transmit the requested variables

Payload

object GetVariableResultList

List of GetVariableResult values

Definition of GetVariableResultList

Example

Minimal payload generated from the schema generated
{
  "items": [
    {
      "status": "Accepted",
      "component_variable": {
        "component": {
          "name": "string"
        },
        "variable": {
          "name": "string"
        }
      }
    }
  ]
}

receive_reply_set_variables

receive Receive response for the respective variables
Topic
Dynamic: the replyTo address from the request's headers. Answers send_request_set_variables.
Message Reply set variables application/json

Message receive_reply_set_variables

Reply to the request to set the variables

Payload

object SetVariableResultList

List of SetVariableResult values

Definition of SetVariableResultList

Example

Minimal payload generated from the schema generated
{
  "items": [
    {
      "status": "Accepted",
      "component_variable": {
        "component": {
          "name": "string"
        },
        "variable": {
          "name": "string"
        }
      }
    }
  ]
}

receive_reply_monitor_and_get_variables

receive Receive the current values of the variables now being monitored
Topic
Dynamic: the replyTo address from the request's headers. Answers send_request_monitor_and_get_variables.
Message Reply monitor and get variables application/json

Message receive_reply_monitor_and_get_variables

Reply with the current values of the variables now being monitored

Payload

object GetVariableResultList

List of GetVariableResult values

Definition of GetVariableResultList

Example

Minimal payload generated from the schema generated
{
  "items": [
    {
      "status": "Accepted",
      "component_variable": {
        "component": {
          "name": "string"
        },
        "variable": {
          "name": "string"
        }
      }
    }
  ]
}

receive_reply_change_availability

receive Receive response to the change availability request
Topic
Dynamic: the replyTo address from the request's headers. Answers send_request_change_availability.
Message Reply to change availability request application/json

Message receive_reply_change_availability

Reply to the request to change the availability

Payload

object ChangeAvailabilityResponse

Response type to request to change the availability of the Charging Station/ an EVSE / a Connector.

Definition of ChangeAvailabilityResponse

Example

Example 1
{
  "status": "Accepted",
  "status_info": {
    "reason_code": "string",
    "additional_info": "string"
  }
}

receive_ocpp_transaction_event

receive Receive is OCPP transaction event
Topic
everest_api/1/ocpp_consumer/{module_id}/e2m/ocpp_transaction_event
Message Receive OCPP transction event application/json

Message receive_ocpp_transaction_event

Events related to OCPP transactions

Payload

object OcppTransactionEvent

Element providing information on OCPP transactions.

Definition of OcppTransactionEvent

Example

Minimal payload generated from the schema generated
{
  "transaction_event": "Started",
  "session_id": "string",
  "timestamp": "2019-08-24T14:15:22Z"
}

receive_is_connected

receive Receive is connected
Topic
everest_api/1/ocpp_consumer/{module_id}/e2m/is_connected

Deprecated: use receive_connection_status instead, which reports the same connection state in its connected property together with the connection details.

Message Receive is connected application/json

Message receive_is_connected

Deprecated: use receive_connection_status instead. Indicates if chargepoint is connected to CSMS

Payload

Deprecated: use ConnectionStatus (connection_status) instead. Indicates if chargepoint is connected to CSMS

Example

Minimal payload generated from the schema generated
true

receive_connection_status

receive Receive connection status
Topic
everest_api/1/ocpp_consumer/{module_id}/e2m/connection_status
Message Receive connection status application/json

Message receive_connection_status

Indicates if the chargepoint is connected to the CSMS and reports the details of the connection the status refers to. Published on every connect and disconnect, replacing the deprecated is_connected variable.

Payload

object ConnectionStatus

Status of the connection of the chargepoint to the CSMS, including the details of the connection the status refers to. While connected, the details describe the active connection; while disconnected, they describe the connection that has just been lost or whose connection attempt has just failed. Details that are not available for the active OCPP version are omitted.

Definition of ConnectionStatus

Example

Minimal payload generated from the schema generated
{
  "connected": true
}

receive_implementation_ready

receive Receive implementation ready
Topic
everest_api/1/ocpp_consumer/{module_id}/e2m/implementation_ready
Message Receive implementation ready application/json

Message receive_implementation_ready

Indicates whether the OCPP implementation behind this API accepts commands

True means the OCPP module has finished its startup and accepts the commands offered by this API. Before that, commands are answered with Rejected or Offline results. The heartbeat of this API only proves that the bridge module itself is alive.

Payload

Indicates whether the OCPP implementation has finished its startup and accepts commands on this API. Unrelated to CSMS connectivity (see ConnectionStatus).

Example

Minimal payload generated from the schema generated
true

receive_security_event

receive Receive security event
Topic
everest_api/1/ocpp_consumer/{module_id}/e2m/security_event
Message Receive security event application/json

Message receive_security_event

Published when an internal sucurity event occured

Payload

object SecurityEvent

Type for a security event

Definition of SecurityEvent

Example

Minimal payload generated from the schema generated
{
  "type": "string"
}

receive_reply_get_ocpp_transaction_event

receive Reply to get ocpp transaction event request
Topic
Dynamic: the replyTo address from the request's headers. Answers send_request_get_ocpp_transaction_event.
Message Reply to get ocpp transaction event request application/json

Message receive_reply_get_ocpp_transaction_event

The most recently published ocpp transaction event.

Payload

oneOf

Exactly one of:

Example

Minimal payload generated from the schema generated
{
  "transaction_event": "Started",
  "session_id": "string",
  "timestamp": "2019-08-24T14:15:22Z"
}

receive_reply_get_security_event

receive Reply to get security event request
Topic
Dynamic: the replyTo address from the request's headers. Answers send_request_get_security_event.
Message Reply to get security event request application/json

Message receive_reply_get_security_event

The most recently published security event.

Payload

oneOf

Exactly one of:

Example

Minimal payload generated from the schema generated
{
  "type": "string"
}

receive_boot_notification_response

receive Receive boot notification response
Topic
everest_api/1/ocpp_consumer/{module_id}/e2m/boot_notification_response
Message Receive boot notification response application/json

Message receive_boot_notification_response

Published any time a BootNotificationResponse message is received from the CSMS

Payload

object BootNotificationResponse

OCPP BootNotificationResponse

Definition of BootNotificationResponse

Example

Minimal payload generated from the schema generated
{
  "status": "Accepted",
  "current_time": "2019-08-24T14:15:22Z",
  "interval": 0
}

receive_reply_get_boot_notification_response

receive Reply to get boot notification response request
Topic
Dynamic: the replyTo address from the request's headers. Answers send_request_get_boot_notification_response.
Message Reply to get boot notification response request application/json

Message receive_reply_get_boot_notification_response

The most recently published boot notification response.

Payload

oneOf

Exactly one of:

Example

Minimal payload generated from the schema generated
{
  "status": "Accepted",
  "current_time": "2019-08-24T14:15:22Z",
  "interval": 0
}

receive_event_data

receive Receive event data
Topic
everest_api/1/ocpp_consumer/{module_id}/e2m/event_data
Message Receive event data application/json

Message receive_event_data

Published for a component variable combination when a variable with a monitor has been changed

Payload

object EventData

Type to report an event notification for a component-variable

Definition of EventData

Example

Minimal payload generated from the schema generated
{
  "component_variable": {
    "component": {
      "name": "string"
    },
    "variable": {
      "name": "string"
    }
  },
  "event_id": 0,
  "timestamp": "2019-08-24T14:15:22Z",
  "trigger": "Alerting",
  "actual_value": "string",
  "event_notification_type": "HardWiredNotification"
}

receive_reply_get_event_data

receive Reply to get event data request
Topic
Dynamic: the replyTo address from the request's headers. Answers send_request_get_event_data.
Message Reply to get event data request application/json

Message receive_reply_get_event_data

The most recently published event data.

Payload

oneOf

Exactly one of:

Example

Minimal payload generated from the schema generated
{
  "component_variable": {
    "component": {
      "name": "string"
    },
    "variable": {
      "name": "string"
    }
  },
  "event_id": 0,
  "timestamp": "2019-08-24T14:15:22Z",
  "trigger": "Alerting",
  "actual_value": "string",
  "event_notification_type": "HardWiredNotification"
}

receive_charging_schedules

receive Receive composite charging schedules
Topic
everest_api/1/ocpp_consumer/{module_id}/e2m/charging_schedules
Message Receive composite charging schedules application/json

Message receive_charging_schedules

Object that contains OCPP charging schedules of all connectors

The object contains one composite charging schedule for each connector id starting from connector 0. Connector 0 contains a schedule for the whole charging station.

The frequency of publication is controlled by PublishChargingScheduleIntervalS (OCPP 2.x) and CompositeScheduleIntervalS (OCPP 1.6)

The duration of the composite schedules is controlled by PublishChargingScheduleDurationS (OCPP 2.x) and RequestCompositeScheduleDurationS (OCPP 1.6)

Payload

object ChargingSchedules

schedules for connectors

Definition of ChargingSchedules

Example

Minimal payload generated from the schema generated
{
  "schedules": [
    {
      "evse": 0,
      "charging_rate_unit": "string",
      "charging_schedule_period": [
        {
          "start_period": 0,
          "limit": 0
        }
      ]
    }
  ]
}

receive_reply_get_is_connected

receive Reply to get Is Connected request
Topic
Dynamic: the replyTo address from the request's headers. Answers send_request_get_is_connected.
Message Reply to get Is Connected request application/json

Message receive_reply_get_is_connected

Deprecated: use receive_reply_get_connection_status instead. The most recently published Is Connected.

Payload

oneOf

Exactly one of:

  • #1boolean ConnectedStatus

    Deprecated: use ConnectionStatus (connection_status) instead. Indicates if chargepoint is connected to CSMS

  • #2null

Example

Minimal payload generated from the schema generated
true

receive_reply_get_connection_status

receive Reply to get Connection Status request
Topic
Dynamic: the replyTo address from the request's headers. Answers send_request_get_connection_status.
Message Reply to get Connection Status request application/json

Message receive_reply_get_connection_status

The most recently published Connection Status.

Payload

oneOf

Exactly one of:

  • #1object ConnectionStatus

    Status of the connection of the chargepoint to the CSMS, including the details of the connection the status refers to. While connected, the details describe the active connection; while disconnected, they describe the connection that has just been lost or whose connection attempt has just failed. Details that are not available for the active OCPP version are omitted.

    Definition of ConnectionStatus

  • #2null

Example

Minimal payload generated from the schema generated
{
  "connected": true
}

receive_reply_get_implementation_ready

receive Reply to get Implementation Ready request
Topic
Dynamic: the replyTo address from the request's headers. Answers send_request_get_implementation_ready.
Message Reply to get Implementation Ready request application/json

Message receive_reply_get_implementation_ready

The most recently published Implementation Ready.

Payload

oneOf

Exactly one of:

  • Indicates whether the OCPP implementation has finished its startup and accepts commands on this API. Unrelated to CSMS connectivity (see ConnectionStatus).

  • #2null

Example

Minimal payload generated from the schema generated
true

receive_reply_get_charging_schedules

receive Reply to get Charging Schedules request
Topic
Dynamic: the replyTo address from the request's headers. Answers send_request_get_charging_schedules.
Message Reply to get Charging Schedules request application/json

Message receive_reply_get_charging_schedules

The most recently published Charging Schedules.

Payload

oneOf

Exactly one of:

Example

Minimal payload generated from the schema generated
{
  "schedules": [
    {
      "evse": 0,
      "charging_rate_unit": "string",
      "charging_schedule_period": [
        {
          "start_period": 0,
          "limit": 0
        }
      ]
    }
  ]
}

receive_ocpp_message

receive Receive ocpp message
Topic
everest_api/1/ocpp_consumer/{module_id}/e2m/ocpp_message

A serialized OCPP message

Message Receive ocpp message application/json

Message receive_ocpp_message

A serialized OCPP message

Payload

object Message

OCPP message with direction

Definition of Message

Example

Minimal payload generated from the schema generated
{
  "message": "string",
  "direction": "CSMSToChargingStation"
}

receive_reply_get_ocpp_message

receive Reply to get ocpp message request
Topic
Dynamic: the replyTo address from the request's headers. Answers send_request_get_ocpp_message.
Message Reply to get ocpp message request application/json

Message receive_reply_get_ocpp_message

The most recently published ocpp message.

Payload

oneOf

Exactly one of:

Example

Minimal payload generated from the schema generated
{
  "message": "string",
  "direction": "CSMSToChargingStation"
}

receive_heartbeat

receive Receive heartbeat
Topic
everest_api/1/ocpp_consumer/{module_id}/e2m/heartbeat
Message Receive heartbeat application/json

Message receive_heartbeat

Heartbeat produced by EVerest as configured via cfg_heartbeat_interval_ms in the EVerest configuration

The heartbeat signals that the bridge module serving this API is alive. It says nothing about the readiness of the OCPP module behind it. See receive_implementation_ready for that.

Payload

integer HeartBeatId

64bit unsigned integer. The id of every heartbeat increases by 1 and overflows when the maximum representable value is reached

Example

Heartbeat
42

Messages

MessageSummaryUsed by
receive_request_data_transfer_incoming
Request data transfer

Request data transfer.

receive_request_data_transfer_incoming
send_reply_data_transfer_incoming
Reply to data transfer request

Reply to the request to transfer data

send_reply_data_transfer_incoming
send_request_data_transfer_outgoing
Request data transfer

Request data transfer.

send_request_data_transfer_outgoing
receive_reply_data_transfer_outgoing
Reply to data transfer request

Reply to the request to transfer data

receive_reply_data_transfer_outgoing
send_request_get_variables
Request variables

Request the variables.

send_request_get_variables
receive_reply_get_variables
Request variables

Reply to the request transmit the requested variables

receive_reply_get_variables
send_request_set_variables
Request set variables

Request setting the variables.

send_request_set_variables
receive_reply_set_variables
Reply set variables

Reply to the request to set the variables

receive_reply_set_variables
send_request_monitor_variables
Monitor variables

Monitor the variables.

send_request_monitor_variables
send_request_monitor_and_get_variables
Monitor variables and read their current values

Monitor the variables and receive their current values in the reply.

send_request_monitor_and_get_variables
receive_reply_monitor_and_get_variables
Reply monitor and get variables

Reply with the current values of the variables now being monitored

receive_reply_monitor_and_get_variables
send_request_change_availability
Request change availability

Request to change the availability of the Charging Station / an EVSE / a Connector.

send_request_change_availability
receive_reply_change_availability
Reply to change availability request

Reply to the request to change the availability

receive_reply_change_availability
send_request_security_event
Trigger security event

Trigger a security event.

send_request_security_event
receive_ocpp_transaction_event
Receive OCPP transction event

Events related to OCPP transactions

receive_ocpp_transaction_event
send_request_get_ocpp_transaction_event
Request current ocpp transaction event

Request the most recently published (latched) ocpp transaction event.

send_request_get_ocpp_transaction_event
receive_reply_get_ocpp_transaction_event
Reply to get ocpp transaction event request

The most recently published ocpp transaction event.

receive_reply_get_ocpp_transaction_event
receive_is_connected
Receive is connected

Deprecated: use receive_connection_status instead. Indicates if chargepoint is connected to CSMS

receive_is_connected
receive_connection_status
Receive connection status

Indicates if the chargepoint is connected to the CSMS and reports the details of the connection the status refers to. Published on every connect and disconnect, replacing the deprecated is_connected variable.

receive_connection_status
receive_implementation_ready
Receive implementation ready

Indicates whether the OCPP implementation behind this API accepts commands

receive_implementation_ready
receive_security_event
Receive security event

Published when an internal sucurity event occured

receive_security_event
send_request_get_security_event
Request current security event

Request the most recently published (latched) security event.

send_request_get_security_event
receive_reply_get_security_event
Reply to get security event request

The most recently published security event.

receive_reply_get_security_event
receive_boot_notification_response
Receive boot notification response

Published any time a BootNotificationResponse message is received from the CSMS

receive_boot_notification_response
send_request_get_boot_notification_response
Request current boot notification response

Request the most recently published (latched) boot notification response.

send_request_get_boot_notification_response
receive_reply_get_boot_notification_response
Reply to get boot notification response request

The most recently published boot notification response.

receive_reply_get_boot_notification_response
receive_event_data
Receive event data

Published for a component variable combination when a variable with a monitor has been changed

receive_event_data
send_request_get_event_data
Request current event data

Request the most recently published (latched) event data.

send_request_get_event_data
receive_reply_get_event_data
Reply to get event data request

The most recently published event data.

receive_reply_get_event_data
receive_charging_schedules
Receive composite charging schedules

Object that contains OCPP charging schedules of all connectors

receive_charging_schedules
send_request_get_is_connected
Request current Is Connected

Deprecated: use send_request_get_connection_status instead. Request the most recently published (latched) Is Connected.

send_request_get_is_connected
receive_reply_get_is_connected
Reply to get Is Connected request

Deprecated: use receive_reply_get_connection_status instead. The most recently published Is Connected.

receive_reply_get_is_connected
send_request_get_connection_status
Request current Connection Status

Request the most recently published (latched) Connection Status.

send_request_get_connection_status
receive_reply_get_connection_status
Reply to get Connection Status request

The most recently published Connection Status.

receive_reply_get_connection_status
send_request_get_implementation_ready
Request current Implementation Ready

Request the most recently published (latched) Implementation Ready.

send_request_get_implementation_ready
receive_reply_get_implementation_ready
Reply to get Implementation Ready request

The most recently published Implementation Ready.

receive_reply_get_implementation_ready
send_request_get_charging_schedules
Request current Charging Schedules

Request the most recently published (latched) Charging Schedules.

send_request_get_charging_schedules
receive_reply_get_charging_schedules
Reply to get Charging Schedules request

The most recently published Charging Schedules.

receive_reply_get_charging_schedules
receive_ocpp_message
Receive ocpp message

A serialized OCPP message

receive_ocpp_message
send_request_get_ocpp_message
Request current ocpp message

Request the most recently published (latched) ocpp message.

send_request_get_ocpp_message
receive_reply_get_ocpp_message
Reply to get ocpp message request

The most recently published ocpp message.

receive_reply_get_ocpp_message
receive_heartbeat
Receive heartbeat

Heartbeat produced by EVerest as configured via cfg_heartbeat_interval_ms in the EVerest configuration

receive_heartbeat
send_communication_check
Send communication check

Signal to EVerest that communication is good or check shall be stopped

send_communication_check

Schemas

AttributeEnum string
string

Attribute enum

  • Actual: The actual value of a variable
  • Target: The target value of a variable
  • MinSet: The minimal allowed value of a variable
  • MaxSet: The maximum allowed value of a variable
enumActualTargetMinSetMaxSet
BootNotificationResponse object
object

OCPP BootNotificationResponse

Additional properties allowed.

  • statusstring requiredRegistrationStatus

    Indicates whether the Charging Station has been registered within the OCPP CSMS

    enumAcceptedPendingRejected
  • current_timestring required

    Contains the CSMS current time in RFC3339 format

    format date-time
  • intervalinteger required

    When Status is Accepted, this contains the heartbeat interval in seconds. If the CSMS returns something other than Accepted, the value of the interval field indicates the minimum wait time before sending a next BootNotification request.

  • status_infoobject StatusInfoType

    Detailed status information.

    Definition of StatusInfoType

OperationalStatusEnumType string
string

Operational status of Charging Station /EVSE / Connector

enumInoperativeOperative
ChangeAvailabilityRequest object
object

Request type to change the availability of the Charging Station/ an EVSE / a Connector.

Additional properties allowed.

  • operational_statusstring requiredOperationalStatusEnumType

    Type of availability change that the Charging Station should perform.

    enumInoperativeOperative
  • evseobject EVSE

    Specify EVSE/Connector whose status is changed. When omitted, the message refers to the Charging Station as a whole.

    Definition of EVSE

ChangeAvailabilityStatusEnumType string
string

Status returned in response to ChangeAvailabilityRequest.

enumAcceptedRejectedScheduled
ChangeAvailabilityResponse object
object

Response type to request to change the availability of the Charging Station/ an EVSE / a Connector.

Additional properties allowed.

EventData object
object

Type to report an event notification for a component-variable

Additional properties allowed.

  • component_variableobject requiredComponentVariable

    Identifier for which the event occurred

    Definition of ComponentVariable

  • event_idinteger required

    Identifies the event

  • timestampstring required

    Timestamp of the moment the report was generated in RFC3339 format

    format date-time
  • triggerstring requiredEventTriggerEnum

    Type of the monitor that triggered this event

    enumAlertingDeltaPeriodic
  • actual_valuestring required

    Actual value of the variable

    max length 2500
  • event_notification_typestring requiredEventNotificationType

    Type of the event notification

    enumHardWiredNotificationHardWiredMonitorPreconfiguredMonitorCustomMonitor
  • causeinteger

    Refers to the Id of an event that is considered to be the cause for this event

  • tech_codestring

    Technical (error) code as reported by component

    max length 50
  • tech_infostring

    Technical detail information as reported by component

    max length 500
  • clearedboolean

    Cleared is set to true to report the clearing of a monitored situation

  • transaction_idstring

    If an event notification is linked to a specific transaction, this field can be used to specify its transactionId

    max length 36
  • variable_monitoring_idinteger

    Identifies the VariableMonitoring which triggered the event

V2XFreqWattPointType object
object

A point of a frequency-watt curve.

Additional properties allowed.

  • frequencynumber required

    Net frequency in Hz

  • powernumber required

    Power in W to charge (positive) or discharge (negative) at specified frequency.

V2XSignalWattPointCurve object
object

A point of a signal-watt curve.

Additional properties allowed.

  • signalinteger required

    Signal value from an AFRRSignalRequest.

  • powernumber required

    Power in W to charge (positive) or discharge (negative) at specified frequency.

ChargingSchedulePeriod object
object

Element providing information on a charging schedule period.

Additional properties allowed.

  • start_periodinteger required
  • limitnumber required

    Optional only when not required by the operationMode, as in CentralSetpoint, ExternalSetpoint, ExternalLimits, LocalFrequency, LocalLoadBalancing. Charging rate limit during the schedule period, in the applicable chargingRateUnit. This SHOULD be a non-negative value; a negative value is only supported for backwards compatibility with older systems that use a negative value to specify a discharging limit. When using chargingRateUnit = W, this field represents the sum of the power of all phases, unless values are provided for L2 and L3, in which case this field represents phase L1.

  • limit_L2number

    Charging rate limit on phase L2 in the applicable chargingRateUnit.

  • limit_L3number

    Charging rate limit on phase L3 in the applicable chargingRateUnit.

  • number_phasesinteger
  • stack_levelinteger
  • phase_to_useinteger
  • discharge_limitnumber

    value <= 0. Limit in chargingRateUnit that the EV is allowed to discharge with. Note, these are negative values in order to be consistent with setpoint, which can be positive and negative. For AC this field represents the sum of all phases, unless values are provided for L2 and L3, in which case this field represents phase L1.

  • discharge_limit_L2number

    Limit in chargingRateUnit on phase L2 that the EV is allowed to discharge with

  • discharge_limit_L3number

    Limit in chargingRateUnit on phase L3 that the EV is allowed to discharge with

  • setpointnumber

    Setpoint in chargingRateUnit that the EV should follow as close as possible. Use negative values for discharging. When a limit and/or dischargeLimit are given the overshoot when following setpoint must remain within these values. This field represents the sum of all phases,unless values are provided for L2 and L3, in which case this field represents phase L1.

  • setpoint_L2number

    Setpoint in chargingRateUnit that the EV should follow on phase L2 as close as possible.

  • setpoint_L3number

    Setpoint in chargingRateUnit that the EV should follow on phase L3 as close as possible.

  • setpoint_reactivenumber

    Setpoint for reactive power (or current) in chargingRateUnit that the EV should follow as closely as possible. Positive values for inductive, negative for capacitive reactive power or current. This field represents the sum of all phases, unless values are provided for L2 and L3, in which case this field represents phase L1.

  • setpoint_reactive_L2number

    Setpoint for reactive power (or current) in chargingRateUnit that the EV should follow on phase L2 as closely as possible.

  • setpoint_reactive_L3number

    Setpoint for reactive power (or current) in chargingRateUnit that the EV should follow on phase L3 as closely as possible.

  • preconditioning_requestboolean

    If true, the EV should attempt to keep the BMS preconditioned for this time interval.

  • evse_sleepboolean

    If true, the EVSE must turn off power electronics/modules associated with this transaction. Default value when absent is false.

  • v2x_baselinenumber

    Power value that, when present, is used as a baseline on top of which values from v2xFreqWattCurve and v2xSignalWattCurve are added

  • operation_modestring

    Operation mode for (bi-)directional charging during a charging schedule period.

    enumIdleChargingOnlyCentralSetpointExternalSetpointExternalLimitsCentralFrequencyLocalFrequencyLocalLoadBalancing
  • v2x_freq_watt_curvearray<object>

    Only required when operationMode = LocalFrequency. When used it must contain at least two coordinates to specify a power-frequency table to use during this period. The table determines the value of setpoint power for a given frequency. chargingRateUnit must be W for LocalFrequency control.

  • v2x_signal_watt_curvearray<object>

    Only used, but not required, when operationMode = LocalFrequency. When used it must contain at least two coordinates to specify a signal-frequency curve to use during this period. The curve determines the value of setpoint power for a given signal. chargingRateUnit must be W for LocalFrequency control.

ChargingSchedule object
object

Element providing information on an OCPP charging schedule.

Additional properties allowed.

  • evseinteger required

    The OCPP 2.0.1 EVSE ID (not used in OCPP 1.6).

    min 0
  • charging_rate_unitstring required
  • charging_schedule_periodarray<object> required
  • durationinteger
  • start_schedulestring
  • min_charging_ratenumber
ChargingSchedules object
object

schedules for connectors

Additional properties allowed.

EventTriggerEnum string
string

Indicates the trigger reason of a generic event as part of the type EventData Alerting: Monitored variable has passed an Lower or Upper Threshold Delta: Delta Monitored Variable value has changed by more than specified amount Periodic: Periodic Monitored Variable has been sampled for reporting at the specified interval

enumAlertingDeltaPeriodic
EventNotificationType string
string

Indicates the event notification type as part of the type EventData HardWiredNotification: The software implemented by the manufacturer triggered a hardwired notification HardWiredMonitor: Triggered by a monitor, which is hardwired by the manufacturer PreconfiguredMonitor: Triggered by a monitor, which is preconfigured by the manufacturer. CustomMonitor: Triggered by a monitor which is set by a message by the Charging Station Operator.

enumHardWiredNotificationHardWiredMonitorPreconfiguredMonitorCustomMonitor
Component object
object

Type for a component with name, optional instance and optional evse For OCPP1.6: A definition of a Component doesn't exist in OCPP1.6; In the context of OCPP1.6 this type may not be relevant or used. For OCPP2.0.1: All properties of the Component can be used

Additional properties allowed.

  • namestring required

    Name of a component

    min length 0max length 50
  • instancestring

    Name of instance in case the component exists as multiple instances

    min length 0max length 50
  • evseobject EVSE

    Specifies the EVSE when component is located at EVSE level, also specifies the connector when component is located at Connector level

    Definition of EVSE

ComponentVariable object
object

Type for a combination of component and variable. Note that for OCPP1.6 only the Variable.name (configuration key) is sufficient to identify a configuration key. For OCPP2.0.1 all properties of the type(s) can be used.

Additional properties allowed.

ConnectedStatus boolean
boolean

Deprecated: use ConnectionStatus (connection_status) instead. Indicates if chargepoint is connected to CSMS

ConnectionStatus object
object

Status of the connection of the chargepoint to the CSMS, including the details of the connection the status refers to. While connected, the details describe the active connection; while disconnected, they describe the connection that has just been lost or whose connection attempt has just failed. Details that are not available for the active OCPP version are omitted.

Additional properties forbidden.

  • connectedboolean required

    Indicates if the chargepoint is connected to the CSMS

  • csms_urlstring

    CSMS endpoint URL of the connection. OCPP2.x reports ocppCsmsUrl of the network connection profile, OCPP1.6 the CentralSystemURI configuration key.

  • identitystring

    Identity the chargepoint uses towards the CSMS. OCPP2.x reports identity of the network connection profile, OCPP1.6 the ChargePointId.

  • security_profileinteger

    OCPP security profile of the connection. OCPP2.x reports securityProfile of the network connection profile, OCPP1.6 the SecurityProfile configuration key.

  • configuration_slotinteger

    Configuration slot of the network connection profile the connection uses.

  • ocpp_interfacestring

    Network interface of the network connection profile the connection uses

  • ocpp_transportstring

    Transport of the network connection profile the connection uses

  • ocpp_versionstring

    OCPP protocol version in use on the connection (e.g. 1.6, 2.0.1 or 2.1)

ImplementationReady boolean
boolean

Indicates whether the OCPP implementation has finished its startup and accepts commands on this API. Unrelated to CSMS connectivity (see ConnectionStatus).

CustomData object
object

Custom data extension

Additional properties allowed.

  • vendor_idstring required

    Vendor Id to identify the customization, this is also included in the data field and only reproduced for convenience

  • datastring required

    Custom json data object encoded as string

DataTransferRequest object
object

Type for data transfer request provided by OCPP

Additional properties allowed.

  • vendor_idstring required

    Identifies the vendor

  • message_idstring

    Identifies the message

  • datastring

    Data provided by this data transfer

  • custom_dataobject CustomData

    Custom data extension

    Definition of CustomData

DataTransferResponse object
object

Type for data transfer response provided by OCPP

Additional properties allowed.

DataTransferStatus string
string

Data Transfer Status enum

enumAcceptedRejectedUnknownMessageIdUnknownVendorIdOffline
EVSE object
object

Type of an EVSE. If only the id is present, this type identifies an EVSE. If also a connector_id is given, this type identifies a Connector of the EVSE

Additional properties allowed.

  • idinteger required

    Id of the EVSE

    min 1
  • connector_idinteger

    An id to designate a specific connector (on an EVSE) by connector index number

    min 1
GetVariableRequest object
object

Type to request a variable value (OCPP2.0.1) or configuration value (OCPP1.6)

Additional properties allowed.

GetVariableRequestList object
object

List of GetVariableRequest values

Additional properties allowed.

GetVariableResult object
object

Result of a GetVariableRequest

Additional properties allowed.

  • statusstring requiredGetVariableStatusEnumType

    Status of the GetVariableResult

    enumAcceptedRejectedUnknownComponentUnknownVariableNotSupportedAttributeType
  • attribute_typestring AttributeEnum

    AttributeEnum for which the value was requested. When absent, actual is assumed

    enumActualTargetMinSetMaxSet
  • valuestring

    Value of the requested variable and AttributeEnum. Present if and only if the status is Accepted. An empty string when the AttributeEnum is supported but has no value

    min length 0max length 2500
  • component_variableobject requiredComponentVariable

    Identifier for which the value was requested

    Definition of ComponentVariable

GetVariableResultList object
object

List of GetVariableResult values

Additional properties allowed.

GetVariableStatusEnumType string
string

Indicates the status of the GetVariableRequest as part of the GetVariableResult operation

  • Accepted: Variable successfully retrieved
  • Rejected: Request is rejected
  • UnknownComponent: Component is not known
  • UnknownVariable: Variable is not known
  • NotSupportedAttributeType: The AttributeType is not supported
enumAcceptedRejectedUnknownComponentUnknownVariableNotSupportedAttributeType
MonitorVariableRequestList object
object

List of MonitorVariableRequest values

Additional properties allowed.

  • itemsarray required

    List of ComponentVariable values

    • itemsobject ComponentVariable

      Type for a combination of component and variable. Note that for OCPP1.6 only the Variable.name (configuration key) is sufficient to identify a configuration key. For OCPP2.0.1 all properties of the type(s) can be used.

      Definition of ComponentVariable

OcppTransactionEvent object
object

Element providing information on OCPP transactions.

Additional properties allowed.

  • transaction_eventstring requiredTransactionEvent

    The transaction related event.

    enumStartedUpdatedEnded
  • evseobject EVSE

    The OCPP 2.0.1 EVSE associated with the transaction.

    Definition of EVSE

  • session_idstring required

    The EVSE manager assigned session ID.

  • transaction_idstring

    The CSMS assigned transaction ID. A string is used to support OCPP 2.0.1. For OCPP 1.6 the integer is converted to a string

  • timestampstring required

    Time of the transaction event in RFC3339 format. For OCPP 2.x this is the timestamp of the TransactionEventRequest, for OCPP 1.6 the timestamp reported in the corresponding StartTransaction.req or StopTransaction.req. For Updated events in OCPP 1.6 it is the time the StartTransaction.conf that triggers them was processed, because that message carries no timestamp of its own.

    format date-time
RegistrationStatus string
string

Indicates whether the Charging Station has been registered within the OCPP CSMS

enumAcceptedPendingRejected
SecurityEvent object
object

Type for a security event

Additional properties allowed.

  • typestring required

    Type of the security event

  • infostring

    Additional information about the occurred security event

  • criticalboolean

    If set this overwrites the default criticality recommended in the OCPP 2.0.1 appendix. A critical security event is transmitted as a message to the CSMS, a non-critical one is just written to the security log

  • timestampstring

    Timestamp of the moment the security event was generated in RFC3339 format, if absent the current datetime is assumed

    format date-time
SetVariableRequest object
object

Type to request to set a variable or configuration key

Additional properties allowed.

  • component_variableobject requiredComponentVariable

    Identifier for which the value should be set

    Definition of ComponentVariable

  • valuestring required

    Value of the variable that should be set

    min length 0max length 1000
  • attribute_typestring AttributeEnum

    AttributeEnum for which the value should be set. When absent, actual is assumed

    enumActualTargetMinSetMaxSet
SetVariableRequestList object
object

List of SetVariableRequest values

Additional properties allowed.

SetVariableResult object
object

Result of a SetVariableRequest

Additional properties allowed.

  • statusstring requiredSetVariableStatusEnumType

    Status of the SetVariableResult

    enumAcceptedRejectedUnknownComponentUnknownVariableNotSupportedAttributeTypeRebootRequired
  • component_variableobject requiredComponentVariable

    Identifier for which the set of the value should be requested

    Definition of ComponentVariable

  • attribute_typestring AttributeEnum

    AttributeEnum for which the set of the value is requested. When absent, actual is assumed

    enumActualTargetMinSetMaxSet
SetVariableResultList object
object

List of SetVariableResult values

Additional properties allowed.

SetVariableStatusEnumType string
string

Indicates the status of the SetVariableRequest operation as part of the SetVariableResult

  • Accepted: Variable successfully set
  • Rejected: Request is rejected
  • UnknownComponent: Component is not known
  • UnknownVariable: Variable is not known
  • NotSupportedAttributeType: The AttributeType is not supported
  • RebootRequired: A reboot is required
enumAcceptedRejectedUnknownComponentUnknownVariableNotSupportedAttributeTypeRebootRequired
SetVariablesArgs object
object

Arguments for set_variables

Additional properties allowed.

StatusInfoType object
object

Element providing more information about the status.

Additional properties allowed.

  • reason_codestring required

    A predefined code for the reason why the status is returned in this response. The string is case-insensitive.

  • additional_infostring

    Additional text to provide detailed information

TransactionEvent string
string

The transaction event enumeration

enumStartedUpdatedEnded
Variable object
object

Type for a variable with a name and an optional instance For OCPP1.6: A Variable should only contain a name. The name identifies the configuration key. For OCPP2.0.1: All properties of the Variable can be used

Additional properties allowed.

  • namestring required

    Name of a variable

    min length 0max length 50
  • instancestring

    Name of instance in case the variable exists as multiple instances

    min length 0max length 50
MessageDirection string
string

OCPP message direction

enumCSMSToChargingStationChargingStationToCSMS
Message object
object

OCPP message with direction

Additional properties allowed.

  • messagestring required

    Serialized OCPP-J message

  • directionstring requiredMessageDirection

    OCPP message direction

    enumCSMSToChargingStationChargingStationToCSMS
  • versionstring

    OCPP version of the serialized message

CommunicationCheck boolean
boolean

Send true at least every cfg_communication_check_to_s seconds to signal that the client is alive, otherwise EVerest raises a CommunicationFault, which the next message clears. Send false to stop the check until the module restarts.

HeartBeatId integer