.. _everest_api_ocpp_consumer_API: ################### ocpp\_consumer\_API ################### .. container:: everest-api overview .. raw:: html
.. container:: lead EVerest API definition for ocpp (consumer) API for EVerest API clients implementing occp / ocpp\_data\_transfer (consumer). .. raw:: htmlSpecification: ocpp_consumer_API.yaml · pionix:de:everest:ocpp_consumer_API
default mqtt
default local MQTT
localhost:1883everest_api/1/ocpp_consumer/{module_id}{module_id}The ID of the module as defined in the EVerest config file
replyTo address from the request's headers.
Answers receive_request_data_transfer_incoming.application/jsonMessage send_reply_data_transfer_incoming
Reply to the request to transfer data
Payload
Type for data transfer response provided by OCPP
Example
{
"status": "Accepted",
"data": "string",
"custom_data": {
"vendor_id": "string",
"data": "string"
}
}
everest_api/1/ocpp_consumer/{module_id}/m2e/data_transfer_outgoing$message.header#/replyTo as receive_reply_data_transfer_outgoing.application/jsonMessage send_request_data_transfer_outgoing
Request data transfer.
Payload
Address to send the response to. Omit it to discard the response. An invalid address, see the EVerest API explanation, rejects the request.
Type for data transfer request provided by OCPP
Example
{
"headers": {
"replyTo": "everest_api/1/{interface_type}/{module_id}/e2m/{operation_name}/{uuid}"
},
"payload": {
"vendor_id": "string",
"message_id": "string",
"data": "string",
"custom_data": {
"vendor_id": "string",
"data": "string"
}
}
}
everest_api/1/ocpp_consumer/{module_id}/m2e/get_variables$message.header#/replyTo as receive_reply_get_variables.application/jsonMessage send_request_get_variables
Request the variables.
Reads variables using canonical component/variable addressing (e.g. component OCPPCommCtrlr, variable HeartbeatInterval), identical for OCPP 1.6 and 2.x. An empty component.name marks the deprecated OCPP 1.6 legacy key form (variable.name = configuration key); it is only accepted while OCPP 1.6 is active and will be removed per the deprecation policy. A non-empty component.name is never reinterpreted as a configuration key. Each result echoes the requested component_variable and carries a status.
See the OCPPmulti module documentation ("Configuration access" and "Migration from OCPP 1.6 key addressing") for examples and the migration guide.
Payload
Address to send the response to. Omit it to discard the response. An invalid address, see the EVerest API explanation, rejects the request.
List of GetVariableRequest values
Example
{
"headers": {
"replyTo": "everest_api/1/{interface_type}/{module_id}/e2m/{operation_name}/{uuid}"
},
"payload": {
"items": [
{
"component_variable": {
"component": {
"name": "string",
"instance": "string",
"evse": {
"id": 1,
"connector_id": 1
}
},
"variable": {
"name": "string",
"instance": "string"
}
},
"attribute_type": "Actual"
}
]
}
}
everest_api/1/ocpp_consumer/{module_id}/m2e/set_variables$message.header#/replyTo as receive_reply_set_variables.application/jsonMessage send_request_set_variables
Request setting the variables.
Writes variables using the same canonical component/variable addressing as get_variables, identical for OCPP 1.6 and 2.x; the empty-component OCPP 1.6 legacy key form is deprecated and scheduled for removal. Connection-configuration writes (component NetworkConfiguration with the profile slot number as component instance, and the OCPPCommCtrlr/NetworkConfigurationPriority selector) return RebootRequired: the value is validated and persisted immediately and takes effect on the next (re)connect or reboot.
See the OCPPmulti module documentation ("Configuration access" and "Migration from OCPP 1.6 key addressing") for examples and the migration guide.
Payload
Address to send the response to. Omit it to discard the response. An invalid address, see the EVerest API explanation, rejects the request.
Example
{
"headers": {
"replyTo": "everest_api/1/{interface_type}/{module_id}/e2m/{operation_name}/{uuid}"
},
"payload": {
"variables": {
"items": [
{
"component_variable": {
"component": {
"name": "string",
"instance": "string",
"evse": {
"id": 1,
"connector_id": 1
}
},
"variable": {
"name": "string",
"instance": "string"
}
},
"value": "string",
"attribute_type": "Actual"
}
]
},
"source": "string"
}
}
everest_api/1/ocpp_consumer/{module_id}/m2e/monitor_variablesapplication/jsonMessage send_request_monitor_variables
Monitor the variables.
Command to start monitoring the given ComponentVariable(s), using the same canonical component/variable addressing as get_variables, identical for OCPP 1.6 and 2.x; the empty-component OCPP 1.6 legacy key form is deprecated. Changes to monitored variables are published on the event_data channel and echo the addressing form used at registration. Consecutive calls of this operation will not override but extend the existing monitors.
See the OCPPmulti module documentation ("Configuration access" and "Migration from OCPP 1.6 key addressing") for examples and the migration guide.
Payload
List of MonitorVariableRequest values
Example
{
"items": [
{
"component": {
"name": "string",
"instance": "string",
"evse": {
"id": 1,
"connector_id": 1
}
},
"variable": {
"name": "string",
"instance": "string"
}
}
]
}
everest_api/1/ocpp_consumer/{module_id}/m2e/monitor_and_get_variables$message.header#/replyTo as receive_reply_monitor_and_get_variables.application/jsonMessage send_request_monitor_and_get_variables
Monitor the variables and receive their current values in the reply.
Combination of monitor_variables and get_variables in one call: starts monitoring the given ComponentVariable(s) exactly like monitor_variables, using the same canonical component/variable addressing as get_variables, identical for OCPP 1.6 and 2.x; the empty-component OCPP 1.6 legacy key form is deprecated. Changes to monitored variables are published on the event_data channel and echo the addressing form used at registration. Consecutive calls of this operation will not override but extend the existing monitors. Additionally the reply contains the current (Actual) value of every requested variable, with the same order, addressing echo and status semantics as get_variables. The monitors are registered before the values are read, so no update can be lost: every change from registration on is published on the event_data channel, and the reply reflects each variable's state at some point after registration. The reply is not ordered against the event stream, however: a change around the call may be reported both in the reply and as an event, and an event may arrive before the reply does. Treat event_data as authoritative for a variable once its first event arrived; use the reply value only until then. This allows registering monitors at startup and obtaining the initial values in a single call without losing an update between the first read and the monitor registration.
See the OCPPmulti module documentation ("Configuration access" and "Migration from OCPP 1.6 key addressing") for examples and the migration guide.
Payload
Address to send the response to. Omit it to discard the response. An invalid address, see the EVerest API explanation, rejects the request.
List of MonitorVariableRequest values
Example
{
"headers": {
"replyTo": "everest_api/1/{interface_type}/{module_id}/e2m/{operation_name}/{uuid}"
},
"payload": {
"items": [
{
"component": {
"name": "string",
"instance": "string",
"evse": {
"id": 1,
"connector_id": 1
}
},
"variable": {
"name": "string",
"instance": "string"
}
}
]
}
}
everest_api/1/ocpp_consumer/{module_id}/m2e/change_availability$message.header#/replyTo as receive_reply_change_availability.application/jsonMessage send_request_change_availability
Request to change the availability of the Charging Station / an EVSE / a Connector.
Allows to send a ChangeAvailabilityRequest internally (as can be done by the CSMS).
Payload
Address to send the response to. Omit it to discard the response. An invalid address, see the EVerest API explanation, rejects the request.
Request type to change the availability of the Charging Station/ an EVSE / a Connector.
Example
{
"headers": {
"replyTo": "everest_api/1/{interface_type}/{module_id}/e2m/{operation_name}/{uuid}"
},
"payload": {
"operational_status": "Inoperative",
"evse": {
"id": 1,
"connector_id": 1
}
}
}
everest_api/1/ocpp_consumer/{module_id}/m2e/security_eventapplication/jsonMessage send_request_security_event
Trigger a security event.
Triggers a SecurityEventNotification.req at the CSMS if it is deemed critical, either by setting the flag in this event or if absent automatically by libocpp
Payload
Example
{
"type": "string",
"info": "string",
"critical": true,
"timestamp": "2026-07-30T12:00:00Z"
}
everest_api/1/ocpp_consumer/{module_id}/m2e/ocpp_transaction_event/get$message.header#/replyTo as receive_reply_get_ocpp_transaction_event.application/jsonMessage send_request_get_ocpp_transaction_event
Request the most recently published (latched) ocpp transaction event.
Payload
Address to send the response to. Omit it to discard the response. An invalid address, see the EVerest API explanation, rejects the request.
Example
{
"headers": {
"replyTo": "everest_api/1/{interface_type}/{module_id}/e2m/{operation_name}/{uuid}"
}
}
everest_api/1/ocpp_consumer/{module_id}/m2e/security_event/get$message.header#/replyTo as receive_reply_get_security_event.application/jsonMessage send_request_get_security_event
Request the most recently published (latched) security event.
Payload
Address to send the response to. Omit it to discard the response. An invalid address, see the EVerest API explanation, rejects the request.
Example
{
"headers": {
"replyTo": "everest_api/1/{interface_type}/{module_id}/e2m/{operation_name}/{uuid}"
}
}
everest_api/1/ocpp_consumer/{module_id}/m2e/boot_notification_response/get$message.header#/replyTo as receive_reply_get_boot_notification_response.application/jsonMessage send_request_get_boot_notification_response
Request the most recently published (latched) boot notification response.
Payload
Address to send the response to. Omit it to discard the response. An invalid address, see the EVerest API explanation, rejects the request.
Example
{
"headers": {
"replyTo": "everest_api/1/{interface_type}/{module_id}/e2m/{operation_name}/{uuid}"
}
}
everest_api/1/ocpp_consumer/{module_id}/m2e/event_data/get$message.header#/replyTo as receive_reply_get_event_data.application/jsonMessage send_request_get_event_data
Request the most recently published (latched) event data.
Payload
Address to send the response to. Omit it to discard the response. An invalid address, see the EVerest API explanation, rejects the request.
Example
{
"headers": {
"replyTo": "everest_api/1/{interface_type}/{module_id}/e2m/{operation_name}/{uuid}"
}
}
everest_api/1/ocpp_consumer/{module_id}/m2e/is_connected/get$message.header#/replyTo as receive_reply_get_is_connected.application/jsonMessage send_request_get_is_connected
Deprecated: use send_request_get_connection_status instead. Request the most recently published (latched) Is Connected.
Payload
Address to send the response to. Omit it to discard the response. An invalid address, see the EVerest API explanation, rejects the request.
Example
{
"headers": {
"replyTo": "everest_api/1/{interface_type}/{module_id}/e2m/{operation_name}/{uuid}"
}
}
everest_api/1/ocpp_consumer/{module_id}/m2e/connection_status/get$message.header#/replyTo as receive_reply_get_connection_status.application/jsonMessage send_request_get_connection_status
Request the most recently published (latched) Connection Status.
Payload
Address to send the response to. Omit it to discard the response. An invalid address, see the EVerest API explanation, rejects the request.
Example
{
"headers": {
"replyTo": "everest_api/1/{interface_type}/{module_id}/e2m/{operation_name}/{uuid}"
}
}
everest_api/1/ocpp_consumer/{module_id}/m2e/implementation_ready/get$message.header#/replyTo as receive_reply_get_implementation_ready.application/jsonMessage send_request_get_implementation_ready
Request the most recently published (latched) Implementation Ready.
Payload
Address to send the response to. Omit it to discard the response. An invalid address, see the EVerest API explanation, rejects the request.
Example
{
"headers": {
"replyTo": "everest_api/1/{interface_type}/{module_id}/e2m/{operation_name}/{uuid}"
}
}
everest_api/1/ocpp_consumer/{module_id}/m2e/charging_schedules/get$message.header#/replyTo as receive_reply_get_charging_schedules.application/jsonMessage send_request_get_charging_schedules
Request the most recently published (latched) Charging Schedules.
Payload
Address to send the response to. Omit it to discard the response. An invalid address, see the EVerest API explanation, rejects the request.
Example
{
"headers": {
"replyTo": "everest_api/1/{interface_type}/{module_id}/e2m/{operation_name}/{uuid}"
}
}
everest_api/1/ocpp_consumer/{module_id}/m2e/ocpp_message/get$message.header#/replyTo as receive_reply_get_ocpp_message.application/jsonMessage send_request_get_ocpp_message
Request the most recently published (latched) ocpp message.
Payload
Address to send the response to. Omit it to discard the response. An invalid address, see the EVerest API explanation, rejects the request.
Example
{
"headers": {
"replyTo": "everest_api/1/{interface_type}/{module_id}/e2m/{operation_name}/{uuid}"
}
}
everest_api/1/ocpp_consumer/{module_id}/m2e/communication_checkapplication/jsonMessage send_communication_check
Signal to EVerest that communication is good or check shall be stopped
Payload
Send true at least every cfg_communication_check_to_s seconds to signal that the client is alive, otherwise EVerest raises a CommunicationFault, which the next message clears. Send false to stop the check until the module restarts.
Example
true
everest_api/1/ocpp_consumer/{module_id}/e2m/data_transfer_incoming$message.header#/replyTo as send_reply_data_transfer_incoming.application/jsonMessage receive_request_data_transfer_incoming
Request data transfer.
Payload
Address to send the response to.
Type for data transfer request provided by OCPP
Example
{
"headers": {
"replyTo": "string"
},
"payload": {
"vendor_id": "string"
}
}
replyTo address from the request's headers.
Answers send_request_data_transfer_outgoing.application/jsonMessage receive_reply_data_transfer_outgoing
Reply to the request to transfer data
Payload
Type for data transfer response provided by OCPP
Example
{
"status": "Accepted"
}
replyTo address from the request's headers.
Answers send_request_get_variables.application/jsonMessage receive_reply_get_variables
Reply to the request transmit the requested variables
Payload
Example
{
"items": [
{
"status": "Accepted",
"component_variable": {
"component": {
"name": "string"
},
"variable": {
"name": "string"
}
}
}
]
}
replyTo address from the request's headers.
Answers send_request_set_variables.application/jsonMessage receive_reply_set_variables
Reply to the request to set the variables
Payload
Example
{
"items": [
{
"status": "Accepted",
"component_variable": {
"component": {
"name": "string"
},
"variable": {
"name": "string"
}
}
}
]
}
replyTo address from the request's headers.
Answers send_request_monitor_and_get_variables.application/jsonMessage receive_reply_monitor_and_get_variables
Reply with the current values of the variables now being monitored
Payload
Example
{
"items": [
{
"status": "Accepted",
"component_variable": {
"component": {
"name": "string"
},
"variable": {
"name": "string"
}
}
}
]
}
replyTo address from the request's headers.
Answers send_request_change_availability.application/jsonMessage receive_reply_change_availability
Reply to the request to change the availability
Payload
Response type to request to change the availability of the Charging Station/ an EVSE / a Connector.
Example
{
"status": "Accepted",
"status_info": {
"reason_code": "string",
"additional_info": "string"
}
}
everest_api/1/ocpp_consumer/{module_id}/e2m/ocpp_transaction_eventapplication/jsonMessage receive_ocpp_transaction_event
Events related to OCPP transactions
Payload
Element providing information on OCPP transactions.
Example
{
"transaction_event": "Started",
"session_id": "string",
"timestamp": "2019-08-24T14:15:22Z"
}
everest_api/1/ocpp_consumer/{module_id}/e2m/is_connectedapplication/jsonMessage receive_is_connected
Deprecated: use receive_connection_status instead. Indicates if chargepoint is connected to CSMS
Payload
Deprecated: use ConnectionStatus (connection_status) instead. Indicates if chargepoint is connected to CSMS
Example
true
everest_api/1/ocpp_consumer/{module_id}/e2m/connection_statusapplication/jsonMessage receive_connection_status
Indicates if the chargepoint is connected to the CSMS and reports the details of the connection the status refers to. Published on every connect and disconnect, replacing the deprecated is_connected variable.
Payload
Status of the connection of the chargepoint to the CSMS, including the details of the connection the status refers to. While connected, the details describe the active connection; while disconnected, they describe the connection that has just been lost or whose connection attempt has just failed. Details that are not available for the active OCPP version are omitted.
Example
{
"connected": true
}
everest_api/1/ocpp_consumer/{module_id}/e2m/implementation_readyapplication/jsonMessage receive_implementation_ready
Indicates whether the OCPP implementation behind this API accepts commands
True means the OCPP module has finished its startup and accepts the commands offered by this API. Before that, commands are answered with Rejected or Offline results. The heartbeat of this API only proves that the bridge module itself is alive.
Payload
Indicates whether the OCPP implementation has finished its startup and accepts commands on this API. Unrelated to CSMS connectivity (see ConnectionStatus).
Example
true
everest_api/1/ocpp_consumer/{module_id}/e2m/security_eventapplication/jsonMessage receive_security_event
Published when an internal sucurity event occured
Payload
Example
{
"type": "string"
}
replyTo address from the request's headers.
Answers send_request_get_ocpp_transaction_event.application/jsonMessage receive_reply_get_ocpp_transaction_event
The most recently published ocpp transaction event.
Payload
Exactly one of:
Element providing information on OCPP transactions.
Example
{
"transaction_event": "Started",
"session_id": "string",
"timestamp": "2019-08-24T14:15:22Z"
}
replyTo address from the request's headers.
Answers send_request_get_security_event.application/jsonMessage receive_reply_get_security_event
The most recently published security event.
Payload
Exactly one of:
Example
{
"type": "string"
}
everest_api/1/ocpp_consumer/{module_id}/e2m/boot_notification_responseapplication/jsonMessage receive_boot_notification_response
Published any time a BootNotificationResponse message is received from the CSMS
Payload
Example
{
"status": "Accepted",
"current_time": "2019-08-24T14:15:22Z",
"interval": 0
}
replyTo address from the request's headers.
Answers send_request_get_boot_notification_response.application/jsonMessage receive_reply_get_boot_notification_response
The most recently published boot notification response.
Payload
Example
{
"status": "Accepted",
"current_time": "2019-08-24T14:15:22Z",
"interval": 0
}
everest_api/1/ocpp_consumer/{module_id}/e2m/event_dataapplication/jsonMessage receive_event_data
Published for a component variable combination when a variable with a monitor has been changed
Payload
Type to report an event notification for a component-variable
Example
{
"component_variable": {
"component": {
"name": "string"
},
"variable": {
"name": "string"
}
},
"event_id": 0,
"timestamp": "2019-08-24T14:15:22Z",
"trigger": "Alerting",
"actual_value": "string",
"event_notification_type": "HardWiredNotification"
}
replyTo address from the request's headers.
Answers send_request_get_event_data.application/jsonMessage receive_reply_get_event_data
The most recently published event data.
Payload
Exactly one of:
Type to report an event notification for a component-variable
Example
{
"component_variable": {
"component": {
"name": "string"
},
"variable": {
"name": "string"
}
},
"event_id": 0,
"timestamp": "2019-08-24T14:15:22Z",
"trigger": "Alerting",
"actual_value": "string",
"event_notification_type": "HardWiredNotification"
}
everest_api/1/ocpp_consumer/{module_id}/e2m/charging_schedulesapplication/jsonMessage receive_charging_schedules
Object that contains OCPP charging schedules of all connectors
The object contains one composite charging schedule for each connector id starting from connector 0. Connector 0 contains a schedule for the whole charging station.
The frequency of publication is controlled by PublishChargingScheduleIntervalS (OCPP 2.x) and CompositeScheduleIntervalS (OCPP 1.6)
The duration of the composite schedules is controlled by PublishChargingScheduleDurationS (OCPP 2.x) and RequestCompositeScheduleDurationS (OCPP 1.6)
Payload
Example
{
"schedules": [
{
"evse": 0,
"charging_rate_unit": "string",
"charging_schedule_period": [
{
"start_period": 0,
"limit": 0
}
]
}
]
}
replyTo address from the request's headers.
Answers send_request_get_is_connected.application/jsonMessage receive_reply_get_is_connected
Deprecated: use receive_reply_get_connection_status instead. The most recently published Is Connected.
Payload
Exactly one of:
Deprecated: use ConnectionStatus (connection_status) instead. Indicates if chargepoint is connected to CSMS
Example
true
replyTo address from the request's headers.
Answers send_request_get_connection_status.application/jsonMessage receive_reply_get_connection_status
The most recently published Connection Status.
Payload
Exactly one of:
Status of the connection of the chargepoint to the CSMS, including the details of the connection the status refers to. While connected, the details describe the active connection; while disconnected, they describe the connection that has just been lost or whose connection attempt has just failed. Details that are not available for the active OCPP version are omitted.
Example
{
"connected": true
}
replyTo address from the request's headers.
Answers send_request_get_implementation_ready.application/jsonMessage receive_reply_get_implementation_ready
The most recently published Implementation Ready.
Payload
Exactly one of:
Indicates whether the OCPP implementation has finished its startup and accepts commands on this API. Unrelated to CSMS connectivity (see ConnectionStatus).
Example
true
replyTo address from the request's headers.
Answers send_request_get_charging_schedules.application/jsonMessage receive_reply_get_charging_schedules
The most recently published Charging Schedules.
Payload
Exactly one of:
Example
{
"schedules": [
{
"evse": 0,
"charging_rate_unit": "string",
"charging_schedule_period": [
{
"start_period": 0,
"limit": 0
}
]
}
]
}
everest_api/1/ocpp_consumer/{module_id}/e2m/ocpp_messageapplication/jsonMessage receive_ocpp_message
A serialized OCPP message
Payload
Example
{
"message": "string",
"direction": "CSMSToChargingStation"
}
replyTo address from the request's headers.
Answers send_request_get_ocpp_message.application/jsonMessage receive_reply_get_ocpp_message
The most recently published ocpp message.
Payload
Example
{
"message": "string",
"direction": "CSMSToChargingStation"
}
everest_api/1/ocpp_consumer/{module_id}/e2m/heartbeatapplication/jsonMessage receive_heartbeat
Heartbeat produced by EVerest as configured via cfg_heartbeat_interval_ms in the EVerest configuration
The heartbeat signals that the bridge module serving this API is alive. It says nothing about the readiness of the OCPP module behind it. See receive_implementation_ready for that.
Payload
64bit unsigned integer. The id of every heartbeat increases by 1 and overflows when the maximum representable value is reached
Example
42
Attribute enum
ActualTargetMinSetMaxSetOCPP BootNotificationResponse
Additional properties allowed.
Indicates whether the Charging Station has been registered within the OCPP CSMS
AcceptedPendingRejectedContains the CSMS current time in RFC3339 format
When Status is Accepted, this contains the heartbeat interval in seconds. If the CSMS returns something other than Accepted, the value of the interval field indicates the minimum wait time before sending a next BootNotification request.
Operational status of Charging Station /EVSE / Connector
InoperativeOperativeRequest type to change the availability of the Charging Station/ an EVSE / a Connector.
Additional properties allowed.
Type of availability change that the Charging Station should perform.
InoperativeOperativeSpecify EVSE/Connector whose status is changed. When omitted, the message refers to the Charging Station as a whole.
Status returned in response to ChangeAvailabilityRequest.
AcceptedRejectedScheduledResponse type to request to change the availability of the Charging Station/ an EVSE / a Connector.
Additional properties allowed.
Indicates whether the Charging Station is able to perform the availability change.
AcceptedRejectedScheduledType to report an event notification for a component-variable
Additional properties allowed.
Identifier for which the event occurred
Identifies the event
Timestamp of the moment the report was generated in RFC3339 format
Type of the monitor that triggered this event
AlertingDeltaPeriodicActual value of the variable
Type of the event notification
HardWiredNotificationHardWiredMonitorPreconfiguredMonitorCustomMonitorRefers to the Id of an event that is considered to be the cause for this event
Technical (error) code as reported by component
Technical detail information as reported by component
Cleared is set to true to report the clearing of a monitored situation
If an event notification is linked to a specific transaction, this field can be used to specify its transactionId
Identifies the VariableMonitoring which triggered the event
A point of a frequency-watt curve.
Additional properties allowed.
Net frequency in Hz
Power in W to charge (positive) or discharge (negative) at specified frequency.
A point of a signal-watt curve.
Additional properties allowed.
Signal value from an AFRRSignalRequest.
Power in W to charge (positive) or discharge (negative) at specified frequency.
Element providing information on a charging schedule period.
Additional properties allowed.
Optional only when not required by the operationMode, as in CentralSetpoint, ExternalSetpoint, ExternalLimits, LocalFrequency, LocalLoadBalancing. Charging rate limit during the schedule period, in the applicable chargingRateUnit. This SHOULD be a non-negative value; a negative value is only supported for backwards compatibility with older systems that use a negative value to specify a discharging limit. When using chargingRateUnit = W, this field represents the sum of the power of all phases, unless values are provided for L2 and L3, in which case this field represents phase L1.
Charging rate limit on phase L2 in the applicable chargingRateUnit.
Charging rate limit on phase L3 in the applicable chargingRateUnit.
value <= 0. Limit in chargingRateUnit that the EV is allowed to discharge with. Note, these are negative values in order to be consistent with setpoint, which can be positive and negative. For AC this field represents the sum of all phases, unless values are provided for L2 and L3, in which case this field represents phase L1.
Limit in chargingRateUnit on phase L2 that the EV is allowed to discharge with
Limit in chargingRateUnit on phase L3 that the EV is allowed to discharge with
Setpoint in chargingRateUnit that the EV should follow as close as possible. Use negative values for discharging. When a limit and/or dischargeLimit are given the overshoot when following setpoint must remain within these values. This field represents the sum of all phases,unless values are provided for L2 and L3, in which case this field represents phase L1.
Setpoint in chargingRateUnit that the EV should follow on phase L2 as close as possible.
Setpoint in chargingRateUnit that the EV should follow on phase L3 as close as possible.
Setpoint for reactive power (or current) in chargingRateUnit that the EV should follow as closely as possible. Positive values for inductive, negative for capacitive reactive power or current. This field represents the sum of all phases, unless values are provided for L2 and L3, in which case this field represents phase L1.
Setpoint for reactive power (or current) in chargingRateUnit that the EV should follow on phase L2 as closely as possible.
Setpoint for reactive power (or current) in chargingRateUnit that the EV should follow on phase L3 as closely as possible.
If true, the EV should attempt to keep the BMS preconditioned for this time interval.
If true, the EVSE must turn off power electronics/modules associated with this transaction. Default value when absent is false.
Power value that, when present, is used as a baseline on top of which values from v2xFreqWattCurve and v2xSignalWattCurve are added
Operation mode for (bi-)directional charging during a charging schedule period.
IdleChargingOnlyCentralSetpointExternalSetpointExternalLimitsCentralFrequencyLocalFrequencyLocalLoadBalancingOnly required when operationMode = LocalFrequency. When used it must contain at least two coordinates to specify a power-frequency table to use during this period. The table determines the value of setpoint power for a given frequency. chargingRateUnit must be W for LocalFrequency control.
A point of a frequency-watt curve.
Only used, but not required, when operationMode = LocalFrequency. When used it must contain at least two coordinates to specify a signal-frequency curve to use during this period. The curve determines the value of setpoint power for a given signal. chargingRateUnit must be W for LocalFrequency control.
A point of a signal-watt curve.
Element providing information on an OCPP charging schedule.
Additional properties allowed.
The OCPP 2.0.1 EVSE ID (not used in OCPP 1.6).
schedules for connectors
Additional properties allowed.
array of schedules
Indicates the trigger reason of a generic event as part of the type EventData Alerting: Monitored variable has passed an Lower or Upper Threshold Delta: Delta Monitored Variable value has changed by more than specified amount Periodic: Periodic Monitored Variable has been sampled for reporting at the specified interval
AlertingDeltaPeriodicIndicates the event notification type as part of the type EventData HardWiredNotification: The software implemented by the manufacturer triggered a hardwired notification HardWiredMonitor: Triggered by a monitor, which is hardwired by the manufacturer PreconfiguredMonitor: Triggered by a monitor, which is preconfigured by the manufacturer. CustomMonitor: Triggered by a monitor which is set by a message by the Charging Station Operator.
HardWiredNotificationHardWiredMonitorPreconfiguredMonitorCustomMonitorType for a component with name, optional instance and optional evse For OCPP1.6: A definition of a Component doesn't exist in OCPP1.6; In the context of OCPP1.6 this type may not be relevant or used. For OCPP2.0.1: All properties of the Component can be used
Additional properties allowed.
Name of a component
Name of instance in case the component exists as multiple instances
Specifies the EVSE when component is located at EVSE level, also specifies the connector when component is located at Connector level
Type for a combination of component and variable. Note that for OCPP1.6 only the Variable.name (configuration key) is sufficient to identify a configuration key. For OCPP2.0.1 all properties of the type(s) can be used.
Additional properties allowed.
Deprecated: use ConnectionStatus (connection_status) instead. Indicates if chargepoint is connected to CSMS
Status of the connection of the chargepoint to the CSMS, including the details of the connection the status refers to. While connected, the details describe the active connection; while disconnected, they describe the connection that has just been lost or whose connection attempt has just failed. Details that are not available for the active OCPP version are omitted.
Additional properties forbidden.
Indicates if the chargepoint is connected to the CSMS
CSMS endpoint URL of the connection. OCPP2.x reports ocppCsmsUrl of the network connection profile, OCPP1.6 the CentralSystemURI configuration key.
Identity the chargepoint uses towards the CSMS. OCPP2.x reports identity of the network connection profile, OCPP1.6 the ChargePointId.
OCPP security profile of the connection. OCPP2.x reports securityProfile of the network connection profile, OCPP1.6 the SecurityProfile configuration key.
Configuration slot of the network connection profile the connection uses.
Network interface of the network connection profile the connection uses
Transport of the network connection profile the connection uses
OCPP protocol version in use on the connection (e.g. 1.6, 2.0.1 or 2.1)
Indicates whether the OCPP implementation has finished its startup and accepts commands on this API. Unrelated to CSMS connectivity (see ConnectionStatus).
Custom data extension
Additional properties allowed.
Vendor Id to identify the customization, this is also included in the data field and only reproduced for convenience
Custom json data object encoded as string
Type for data transfer request provided by OCPP
Additional properties allowed.
Identifies the vendor
Identifies the message
Data provided by this data transfer
Type for data transfer response provided by OCPP
Additional properties allowed.
Status of the data transfer
AcceptedRejectedUnknownMessageIdUnknownVendorIdOfflineData provided by this data transfer
Data Transfer Status enum
AcceptedRejectedUnknownMessageIdUnknownVendorIdOfflineType of an EVSE. If only the id is present, this type identifies an EVSE. If also a connector_id is given, this type identifies a Connector of the EVSE
Additional properties allowed.
Id of the EVSE
An id to designate a specific connector (on an EVSE) by connector index number
Type to request a variable value (OCPP2.0.1) or configuration value (OCPP1.6)
Additional properties allowed.
Identifier for which the value should be requested
AttributeEnum for which the value should be requested. When absent, actual is assumed
ActualTargetMinSetMaxSetList of GetVariableRequest values
Additional properties allowed.
List of GetVariableRequest values
Type to request a variable value (OCPP2.0.1) or configuration value (OCPP1.6)
Result of a GetVariableRequest
Additional properties allowed.
Status of the GetVariableResult
AcceptedRejectedUnknownComponentUnknownVariableNotSupportedAttributeTypeAttributeEnum for which the value was requested. When absent, actual is assumed
ActualTargetMinSetMaxSetValue of the requested variable and AttributeEnum. Present if and only if the status is Accepted. An empty string when the AttributeEnum is supported but has no value
Identifier for which the value was requested
List of GetVariableResult values
Additional properties allowed.
List of GetVariableResult values
Indicates the status of the GetVariableRequest as part of the GetVariableResult operation
AcceptedRejectedUnknownComponentUnknownVariableNotSupportedAttributeTypeList of MonitorVariableRequest values
Additional properties allowed.
List of ComponentVariable values
Type for a combination of component and variable. Note that for OCPP1.6 only the Variable.name (configuration key) is sufficient to identify a configuration key. For OCPP2.0.1 all properties of the type(s) can be used.
Element providing information on OCPP transactions.
Additional properties allowed.
The transaction related event.
StartedUpdatedEndedThe EVSE manager assigned session ID.
The CSMS assigned transaction ID. A string is used to support OCPP 2.0.1. For OCPP 1.6 the integer is converted to a string
Time of the transaction event in RFC3339 format. For OCPP 2.x this is the timestamp of the TransactionEventRequest, for OCPP 1.6 the timestamp reported in the corresponding StartTransaction.req or StopTransaction.req. For Updated events in OCPP 1.6 it is the time the StartTransaction.conf that triggers them was processed, because that message carries no timestamp of its own.
Indicates whether the Charging Station has been registered within the OCPP CSMS
AcceptedPendingRejectedType for a security event
Additional properties allowed.
Type of the security event
Additional information about the occurred security event
If set this overwrites the default criticality recommended in the OCPP 2.0.1 appendix. A critical security event is transmitted as a message to the CSMS, a non-critical one is just written to the security log
Timestamp of the moment the security event was generated in RFC3339 format, if absent the current datetime is assumed
Type to request to set a variable or configuration key
Additional properties allowed.
Identifier for which the value should be set
Value of the variable that should be set
AttributeEnum for which the value should be set. When absent, actual is assumed
ActualTargetMinSetMaxSetList of SetVariableRequest values
Additional properties allowed.
List of SetVariableRequest values
Type to request to set a variable or configuration key
Result of a SetVariableRequest
Additional properties allowed.
Status of the SetVariableResult
AcceptedRejectedUnknownComponentUnknownVariableNotSupportedAttributeTypeRebootRequiredIdentifier for which the set of the value should be requested
AttributeEnum for which the set of the value is requested. When absent, actual is assumed
ActualTargetMinSetMaxSetList of SetVariableResult values
Additional properties allowed.
List of SetVariableResult values
Indicates the status of the SetVariableRequest operation as part of the SetVariableResult
AcceptedRejectedUnknownComponentUnknownVariableNotSupportedAttributeTypeRebootRequiredArguments for set_variables
Additional properties allowed.
List of variables
source
Element providing more information about the status.
Additional properties allowed.
A predefined code for the reason why the status is returned in this response. The string is case-insensitive.
Additional text to provide detailed information
The transaction event enumeration
StartedUpdatedEndedType for a variable with a name and an optional instance For OCPP1.6: A Variable should only contain a name. The name identifies the configuration key. For OCPP2.0.1: All properties of the Variable can be used
Additional properties allowed.
Name of a variable
Name of instance in case the variable exists as multiple instances
OCPP message direction
CSMSToChargingStationChargingStationToCSMSOCPP message with direction
Additional properties allowed.
Serialized OCPP-J message
OCPP message direction
CSMSToChargingStationChargingStationToCSMSOCPP version of the serialized message
Send true at least every cfg_communication_check_to_s seconds to signal that the client is alive, otherwise EVerest raises a CommunicationFault, which the next message clears. Send false to stop the check until the module restarts.
64bit unsigned integer. The id of every heartbeat increases by 1 and overflows when the maximum representable value is reached