evse_board_support_API¶
EVerest API definition for EVSE board support
API for EVerest API clients implementing evse board support, AC RCD and connector lock. Commands without arguments carry an empty JSON object ({}) as payload.
Specification: evse_board_support_API.yaml · pionix:de:everest:evse_board_support_API
Servers¶
default mqtt
default local MQTT
- Host
localhost:1883- Topic prefix
everest_api/1/evse_board_support/{module_id}{module_id}The ID of the module as defined in the EVerest config file.
Operations¶
Client to EVerest¶
send_event¶
- Topic
everest_api/1/evse_board_support/{module_id}/m2e/event
Direction: Module to EVerest
Message Send ControlPilot event application/json
Message send_event
Event from ControlPilot signal/out relais
Payload
Example
{
"event": "A"
}
send_ac_nr_of_phases¶
- Topic
everest_api/1/evse_board_support/{module_id}/m2e/ac_nr_of_phases
Direction: Module to EVerest
Message Send phase count application/json
Message send_ac_nr_of_phases
Instantaneous phase count available to car
Values outside 1..3 are rejected with a log warning. Not required at start: the initial phase count comes from max_phase_count_import of the capabilities.
Payload
Example
3
send_capabilities¶
- Topic
everest_api/1/evse_board_support/{module_id}/m2e/capabilities
Direction: Module to EVerest
Message Send hardware capabilities application/json
Message send_capabilities
Hardware capabilities/limits. Publish them once after start, before the first charging session: on AC, EVerest does not offer current before it has them, and on AC and DC they set connector_type and supports_cp_state_E. Publish them again whenever a limit changes, e.g. when the maximum current drops because the hardware gets too hot.
Payload
Example
{
"max_current_A_import": 5,
"min_current_A_import": 1,
"max_phase_count_import": 3,
"min_phase_count_import": 1,
"max_current_A_export": 10,
"min_current_A_export": 1,
"max_phase_count_export": 3,
"min_phase_count_export": 1,
"supports_changing_phases_during_charging": true,
"max_plug_temperature_C": 80,
"supports_cp_state_E": true,
"connector_type": "IEC62196Type2Cable"
}
send_ac_pp_ampacity¶
- Topic
everest_api/1/evse_board_support/{module_id}/m2e/ac_pp_ampacity
Direction: Module to EVerest
Message Send AC pp ampacity application/json
Message send_ac_pp_ampacity
Current carrying capacity of the connected cable in ampere for AC charging with a socket. Publish whenever it changes. This has no meaning for DC or AC charging with a fixed attached cable, it does not need to be implemented and the returned value is not used in those cases.
Payload
Example
{
"ampacity": "None"
}
send_request_stop_transaction¶
- Topic
everest_api/1/evse_board_support/{module_id}/m2e/request_stop_transaction
Direction: Module to EVerest
Message Request stop charging application/json
Message send_request_stop_transaction
Publish to stop the transaction gracefully (e.g. user pressed the stop button)
Payload
object StopTransactionRequest ↗
Request for a stop transaction containing the reason and an optional id tag
Example
{
"reason": "Local"
}
send_reply_reset¶
- Topic
- Dynamic: the
replyToaddress from the request's headers. Answers receive_request_reset.
Reply to request
Message Reply to request for RCD reset application/json
Message send_reply_reset
Reply to provided topic.
Payload
Success: true, failure: false
Example
true
send_rcd_current¶
- Topic
everest_api/1/evse_board_support/{module_id}/m2e/rcd_current
Direction: Module to EVerest
Message Send RCD current application/json
Message send_rcd_current
Residual current in mA. Note that this does not trigger anything, it is merely for reporting.
Payload
Electrical current in milliampere (mA)
Example
1
send_raise_error¶
- Topic
everest_api/1/evse_board_support/{module_id}/m2e/raise_error
Direction: Module to EVerest
Message Send raise error application/json
Message send_raise_error
Signal to EVerest that an error happened.
Payload
object Error
Errors for the evse_board_support interface. All error codes that begin with MREC needs to be implemented to fulfill the Minimum Required Error Codes defined by the ChargeX consortium: https://inl.gov/content/uploads/2023/07/ChargeX_MREC_Rev5_09.12.23.pdf
Example
{
"type": "DiodeFault",
"sub_type": "string",
"message": "string"
}
send_clear_error¶
- Topic
everest_api/1/evse_board_support/{module_id}/m2e/clear_error
Message Send clear error application/json
Message send_clear_error
Signal to EVerest that a previously raised error is no longer active.
Payload
object Error
Errors for the evse_board_support interface. All error codes that begin with MREC needs to be implemented to fulfill the Minimum Required Error Codes defined by the ChargeX consortium: https://inl.gov/content/uploads/2023/07/ChargeX_MREC_Rev5_09.12.23.pdf
Example
{
"type": "DiodeFault",
"sub_type": "string",
"message": "string"
}
send_communication_check¶
- Topic
everest_api/1/evse_board_support/{module_id}/m2e/communication_check
Message Send communication check application/json
Message send_communication_check
Signal to EVerest that communication is good or check shall be stopped
Payload
Send true at least every cfg_communication_check_to_s seconds to signal that the client is alive, otherwise EVerest raises a CommunicationFault, which the next message clears. Send false to stop the check until the module restarts.
Example
true
EVerest to client¶
receive_enable¶
- Topic
everest_api/1/evse_board_support/{module_id}/e2m/enable
Direction: EVerest to Module
Message Receive enable or disable for charging port application/json
Message receive_enable
Enables or disables the charging port. Typically disabled results in control pilot state F. It must not accept cars for new charging sessions if disabled.
Payload
True: enabled. False: disabled.
Example
true
receive_pwm_on¶
- Topic
everest_api/1/evse_board_support/{module_id}/e2m/pwm_on
Direction: EVerest to Module
Message Receive PWM duty cycle application/json
Message receive_pwm_on
Turns PWM on with duty cycle (in percent)
EVerest only requests duty cycles strictly between 0 and 100 (5 % for high level communication, 10 % for 6 A up to 97 % for 80 A). State X1 (no current available, PWM off) is requested with cp_state_X1 and state F with cp_state_F, never as a duty cycle of 100 or 0 here.
Payload
PWM duty cycle in percent, strictly between 0 and 100. EVerest requests 100 % (X1) and 0 % (F) through cp_state_X1 and cp_state_F instead.
Example
100
receive_cp_state_X1¶
- Topic
everest_api/1/evse_board_support/{module_id}/e2m/cp_state_X1
Direction: EVerest to Module
Message Receive CP state X1 application/json
Message receive_cp_state_X1
Turn PWM off and set CP to constant high voltage (state X1)
Payload
No payload.
Example
receive_cp_state_F¶
- Topic
everest_api/1/evse_board_support/{module_id}/e2m/cp_state_F
Direction: EVerest to Module
Message Receive CP state F application/json
Message receive_cp_state_F
Turn PWM off with error F (constant negative voltage)
Payload
No payload.
Example
receive_cp_state_E¶
- Topic
everest_api/1/evse_board_support/{module_id}/e2m/cp_state_E
Direction: EVerest to Module
Message Receive CP state E application/json
receive_allow_power_on¶
- Topic
everest_api/1/evse_board_support/{module_id}/e2m/allow_power_on
Direction: EVerest to Module
Message Receive permission to switch relays on application/json
Message receive_allow_power_on
Sets allow_power_on flag. If false, relays must never be switched on.
Payload
object PowerOnOff
Flag and context for switching power on/off. In some architectures e.g. DC power train needs to know whether it should switch on with limited current or full current on the output contactors.
Example
{
"allow_power_on": true,
"reason": "DCCableCheck"
}
receive_ac_switch_three_phases_while_charging¶
- Topic
everest_api/1/evse_board_support/{module_id}/e2m/ac_switch_three_phases_while_charging
Direction: EVerest to Module
Message Receive request switch between 3 phase and 1 phase mode application/json
Message receive_ac_switch_three_phases_while_charging
Optional, in case of doubt do not implement. Report in hardware_capabilites if this command is supported. This command switches between one and three phase operation during an active charging session. Some cars can be permanently destroyed by that, so the bsp needs to implement a special sequence for the switching. The exact sequence can be defined by the BSP, but one example would be a C2->C1->B1->F->B1->B2->C2 or similar. Use with caution.
Payload
Example
"ThreePhases"
receive_ac_overcurrent_limit¶
- Topic
everest_api/1/evse_board_support/{module_id}/e2m/ac_overcurrent_limit
Direction: EVerest to Module
Message Receive over current limit application/json
Message receive_ac_overcurrent_limit
Many chargers implement a fast over current shutdown directly in the hardware that triggers if the EV draws more current than the PWM allows. If the hardware does not have this functionality, just ignore this command. Do not use it to set the PWM duty cycle. Otherwise this command reports a value that should be used for the overcurrent detection. A margin needs to be added to avoid false triggers. Do not use the PWM duty cycle to infer the current limit in the BSP, as this will not work with HLC.
Payload
Electrical current in ampere (A)
Example
15
receive_self_test¶
- Topic
everest_api/1/evse_board_support/{module_id}/e2m/self_test
Message Receive signal for selftest application/json
Message receive_self_test
Executes a self test of the RCD. If it fails, an error of type Selftest should be raised.
Payload
No payload.
Example
receive_request_reset¶
- Topic
everest_api/1/evse_board_support/{module_id}/e2m/reset- Reply
- Sent to
$message.header#/replyToas send_reply_reset.
Message Request to reset RCD application/json
Message receive_request_reset
Resets the RCD after a trigger. May not be supported by actual hardware.
Payload
-
headersobject required
-
replyTostring required
The topic to which to send the reply
-
Example
{
"headers": {
"replyTo": "everest_api/1/{interface_type}/{module_id}/e2m/{operation_name}/{uuid}"
}
}
receive_lock¶
- Topic
everest_api/1/evse_board_support/{module_id}/e2m/lock
Message Receive signal to lock application/json
receive_unlock¶
- Topic
everest_api/1/evse_board_support/{module_id}/e2m/unlock
Message Receive signal to unlock application/json
Message receive_unlock
Unlock connector lock. (e.g. normal unlock or enforced by OCPP)
Payload
No payload.
Example
receive_heartbeat¶
- Topic
everest_api/1/evse_board_support/{module_id}/e2m/heartbeat
Direction: EVerest to Module
Message Receive heartbeat application/json
Message receive_heartbeat
Heartbeat produced by EVerest as configured via cfg_heartbeat_interval_ms in the EVerest configuration
Payload
64bit unsigned integer. The id of every heartbeat increases by 1 and overflows when the maximum representable value is reached
Example
42
Messages¶
Schemas¶
ACPhaseMode string¶
Number of active phases for AC charging
ThreePhasesSinglePhaseBspEvent object¶
Event stream from ControlPilot signal/relais.
Additional properties allowed.
-
eventstring required
- A-F: CP states as defined in IEC61851-1
- PowerOn: Hardware confirms that contactors switched on correctly (typically mirror contacts indicated successful switch on)
- PowerOff: Hardware confirms that contactors switched off correctly and are not welded (typically mirror contacts indicated successful switch off)
- Disconnected: Only used on EV side: Not connected to a charging station. Do not use on EVSE side.
enumABCDEFPowerOnPowerOffDisconnected
Current number¶
Electrical current in milliampere (mA)
Enabled boolean¶
True: enabled. False: disabled.
HardwareCapabilities object¶
Hardware capabilities / limits
Additional properties allowed.
-
max_current_A_importnumber required
Maximum current (ampere) the hardware can handle (import from grid)
-
min_current_A_importnumber required
Minimum current (ampere) the hardware can use to charge. Values below may be set but may result in pause instead. (import from grid)
-
max_phase_count_importinteger required
Max nr of phases the hardware can use (import from grid)
min 1max 3 -
min_phase_count_importinteger required
Minimum nr of phases the hardware can use (import from grid)
min 1max 3 -
max_current_A_exportnumber required
Maximum current (ampere) the hardware can handle (export to grid)
-
min_current_A_exportnumber required
Minimum current (ampere) the hardware can use to charge. Values below may be set but may result in pause instead. (export to grid)
-
max_phase_count_exportinteger required
Max nr of phases the hardware can use (export to grid)
min 1max 3 -
min_phase_count_exportinteger required
Minimum nr of phases the hardware can use (export to grid)
min 1max 3 -
supports_changing_phases_during_chargingboolean required
Indicates whether changing number of phases is supported during charging (true) or not (false)
-
max_plug_temperature_Cnumber
-
supports_cp_state_Eboolean
Indicates whether setting Control Pilot to state E is supported (true) or not (false). Treated as false when omitted.
default false -
connector_typestring required
Type of charging connector available at this EVSE
enumIEC62196Type2CableIEC62196Type2SocketcCCS1cCCS2cTeslacNACScG105cMCS
OverCurrent number¶
Electrical current in ampere (A)
PhaseCount integer¶
Number of phases
PowerOnOff object¶
Flag and context for switching power on/off. In some architectures e.g. DC power train needs to know whether it should switch on with limited current or full current on the output contactors.
Additional properties allowed.
-
allow_power_onboolean required
Allow switching on (true) or force switching off (false)
-
reasonstring required
Reason for switching on/off
enumDCCableCheckDCPreChargeFullPowerChargingPowerOff
ProximityPilot object¶
Current capability (ampacity) of the cable
Additional properties allowed.
-
ampacitystring required
Ampacity value of the cable assembly
enumNoneA_13A_20A_32A_63_3ph_70_1ph
PWMDutyCycle number¶
PWM duty cycle in percent, strictly between 0 and 100. EVerest requests 100 % (X1) and 0 % (F) through cp_state_X1 and cp_state_F instead.
Success boolean¶
Success: true, failure: false
ErrorEnum string¶
Type of error
- DiodeFault: 'The CP diode in the EV is shorted.'
- VentilationNotAvailable: 'EV requested state D but no ventilation is available.'
- BrownOut: 'The hardware/MCU detected a brown out.'
- EnergyManagement: 'Energy could not be delivered because an (external) energy management failed.'
- PermanentFault: 'The EVSE is permanently broken and requires repair.'
- MREC2GroundFailure: 'Ground fault circuit interrupter has been activated.'
- MREC3HighTemperature: 'High temperature inside the EVSE is derating power delivery.'
- MREC4OverCurrentFailure: 'Over current protection device has tripped.'
- MREC5OverVoltage: 'Input voltage to the vehicle has risen above an acceptable level.'
- MREC6UnderVoltage: 'Input voltage to the vehicle has dropped below an acceptable level.'
- MREC8EmergencyStop: 'Emergency stop is pressed by the user (required if equipped).'
- MREC10InvalidVehicleMode: 'The vehicle is in an invalid mode for charging (Reported by IEC stack)'
- MREC14PilotFault: 'The control pilot voltage is out of range.'
- MREC15PowerLoss: 'The EVSE is unable to supply any power due to mains failure'
- MREC17EVSEContactorFault: "Contactors fail to open or close on EVSE's side. May also include welding related errors."
- MREC18CableOverTempDerate: 'Temperature of charging cable or connector assembly is too high, resulting in reduced power operation.'
- MREC19CableOverTempStop: 'Temperature of charging cable or connector assembly is too high, resulting in a stopped charging session.'
- MREC20PartialInsertion: 'Cable latch is raised due to incomplete insertion into the vehicle charging port.'
- MREC23ProximityFault: 'The proximity voltage is out of range.'
- MREC24ConnectorVoltageHigh: 'The output voltage of EVSE is high before charging starts or after charging ends.'
- MREC25BrokenLatch: 'The latch on the connector is broken.'
- MREC26CutCable: 'The output cable has been severed from the EVSE.'
- ConnectorLockCapNotCharged: 'The capacitor for connector lock motor failed to charge within expected time'
- ConnectorLockUnexpectedOpen: 'The connector lock feedback returns open while it should be closed'
- ConnectorLockUnexpectedClose: 'The connector lock feedback returns closed while it should be open'
- ConnectorLockFailedLock: 'The connector lock failed to lock (feedback still returns open)'
- ConnectorLockFailedUnlock: 'The connector lock failed to unlock (feedback still returns closed)'
- MREC1ConnectorLockFailure: ' Failure to lock or unlock connector on the vehicle side as per MREC definition. How should that be implemented? We can only find out about locking on the EVSE side, so we will use this error to report EVSE side lock failures. It is probably a mistake in the MREC definition.'
- Selftest: 'The Selftest failed, device permanently broken'
- DC: 'RCD was triggered by a DC fault'
- AC: 'RCD was triggered by an AC fault'
- TiltDetected: 'The EVSE has been tilted beyond acceptable limits.'
- WaterIngressDetected: 'A substantial amount of water has been detected inside the EVSE.'
- EnclosureOpen: 'The EVSE enclosure is open, e.g. a door or panel is not properly closed.'
- VendorError: 'Vendor specific error code. Will stop charging session.'
- VendorWarning: 'Vendor specific error code. Charging may continue.'
The ConnectorLock errors and MREC1ConnectorLockFailure are raised on the connector_lock interface, Selftest, DC and AC on ac_rcd, all others on evse_board_support. EvseManager sees connector_lock and ac_rcd errors only if its connector_lock and ac_rcd requirements are connected to this module. Only MREC3HighTemperature, MREC18CableOverTempDerate and VendorWarning let charging continue.
DiodeFaultVentilationNotAvailableBrownOutEnergyManagementPermanentFaultMREC2GroundFailureMREC3HighTemperatureMREC4OverCurrentFailureMREC5OverVoltageMREC6UnderVoltageMREC8EmergencyStopMREC10InvalidVehicleModeMREC14PilotFaultMREC15PowerLossMREC17EVSEContactorFaultMREC18CableOverTempDerateMREC19CableOverTempStopMREC20PartialInsertionMREC23ProximityFaultMREC24ConnectorVoltageHighMREC25BrokenLatchMREC26CutCableConnectorLockCapNotChargedConnectorLockUnexpectedOpenConnectorLockUnexpectedCloseConnectorLockFailedLockConnectorLockFailedUnlockMREC1ConnectorLockFailureSelftestDCACTiltDetectedWaterIngressDetectedEnclosureOpenVendorErrorVendorWarningError object¶
Errors for the evse_board_support interface. All error codes that begin with MREC needs to be implemented to fulfill the Minimum Required Error Codes defined by the ChargeX consortium: https://inl.gov/content/uploads/2023/07/ChargeX_MREC_Rev5_09.12.23.pdf
Additional properties allowed.
-
Type of error
- DiodeFault: 'The CP diode in the EV is shorted.'
- VentilationNotAvailable: 'EV requested state D but no ventilation is available.'
- BrownOut: 'The hardware/MCU detected a brown out.'
- EnergyManagement: 'Energy could not be delivered because an (external) energy management failed.'
- PermanentFault: 'The EVSE is permanently broken and requires repair.'
- MREC2GroundFailure: 'Ground fault circuit interrupter has been activated.'
- MREC3HighTemperature: 'High temperature inside the EVSE is derating power delivery.'
- MREC4OverCurrentFailure: 'Over current protection device has tripped.'
- MREC5OverVoltage: 'Input voltage to the vehicle has risen above an acceptable level.'
- MREC6UnderVoltage: 'Input voltage to the vehicle has dropped below an acceptable level.'
- MREC8EmergencyStop: 'Emergency stop is pressed by the user (required if equipped).'
- MREC10InvalidVehicleMode: 'The vehicle is in an invalid mode for charging (Reported by IEC stack)'
- MREC14PilotFault: 'The control pilot voltage is out of range.'
- MREC15PowerLoss: 'The EVSE is unable to supply any power due to mains failure'
- MREC17EVSEContactorFault: "Contactors fail to open or close on EVSE's side. May also include welding related errors."
- MREC18CableOverTempDerate: 'Temperature of charging cable or connector assembly is too high, resulting in reduced power operation.'
- MREC19CableOverTempStop: 'Temperature of charging cable or connector assembly is too high, resulting in a stopped charging session.'
- MREC20PartialInsertion: 'Cable latch is raised due to incomplete insertion into the vehicle charging port.'
- MREC23ProximityFault: 'The proximity voltage is out of range.'
- MREC24ConnectorVoltageHigh: 'The output voltage of EVSE is high before charging starts or after charging ends.'
- MREC25BrokenLatch: 'The latch on the connector is broken.'
- MREC26CutCable: 'The output cable has been severed from the EVSE.'
- ConnectorLockCapNotCharged: 'The capacitor for connector lock motor failed to charge within expected time'
- ConnectorLockUnexpectedOpen: 'The connector lock feedback returns open while it should be closed'
- ConnectorLockUnexpectedClose: 'The connector lock feedback returns closed while it should be open'
- ConnectorLockFailedLock: 'The connector lock failed to lock (feedback still returns open)'
- ConnectorLockFailedUnlock: 'The connector lock failed to unlock (feedback still returns closed)'
- MREC1ConnectorLockFailure: ' Failure to lock or unlock connector on the vehicle side as per MREC definition. How should that be implemented? We can only find out about locking on the EVSE side, so we will use this error to report EVSE side lock failures. It is probably a mistake in the MREC definition.'
- Selftest: 'The Selftest failed, device permanently broken'
- DC: 'RCD was triggered by a DC fault'
- AC: 'RCD was triggered by an AC fault'
- TiltDetected: 'The EVSE has been tilted beyond acceptable limits.'
- WaterIngressDetected: 'A substantial amount of water has been detected inside the EVSE.'
- EnclosureOpen: 'The EVSE enclosure is open, e.g. a door or panel is not properly closed.'
- VendorError: 'Vendor specific error code. Will stop charging session.'
- VendorWarning: 'Vendor specific error code. Charging may continue.'
The ConnectorLock errors and MREC1ConnectorLockFailure are raised on the connector_lock interface, Selftest, DC and AC on ac_rcd, all others on evse_board_support. EvseManager sees connector_lock and ac_rcd errors only if its connector_lock and ac_rcd requirements are connected to this module. Only MREC3HighTemperature, MREC18CableOverTempDerate and VendorWarning let charging continue.
enumDiodeFaultVentilationNotAvailableBrownOutEnergyManagementPermanentFaultMREC2GroundFailureMREC3HighTemperatureMREC4OverCurrentFailureMREC5OverVoltageMREC6UnderVoltageMREC8EmergencyStopMREC10InvalidVehicleModeMREC14PilotFaultMREC15PowerLossMREC17EVSEContactorFaultMREC18CableOverTempDerateMREC19CableOverTempStopMREC20PartialInsertionMREC23ProximityFaultMREC24ConnectorVoltageHighMREC25BrokenLatchMREC26CutCableConnectorLockCapNotChargedConnectorLockUnexpectedOpenConnectorLockUnexpectedCloseConnectorLockFailedLockConnectorLockFailedUnlockMREC1ConnectorLockFailureSelftestDCACTiltDetectedWaterIngressDetectedEnclosureOpenVendorErrorVendorWarning -
sub_typestring
The subtype of the error
-
messagestring
Optional free-text detail about this specific occurrence of the error, e.g. a measured value or a diagnostic string from the hardware. Unlike the fixed per-error-type description, this is chosen by the caller. If an OCPP module is part of the EVerest configuration, the message is forwarded to the CSMS:
- OCPP 1.6 (
StatusNotification.req): - MREC errors: sent as
info, truncated to 50 characters. Omitted entirely when the message is empty. - all other errors: sent as
vendorId, truncated to 255 characters. - OCPP 2.x (
NotifyEvent.req): sent astechInfo, truncated to 500 characters. When the message is empty, the error description is sent instead.
- OCPP 1.6 (
-
trigger_valueobject
Optional value that caused this specific occurrence of the error, e.g. the measurement that crossed a limit.
-
text_reprstring
Text representation of the value as the raising entity would print it, including a unit where one applies, e.g.
85.3 degC. EVerest passes it on as is and does not parse it. Longer values are truncated to 2500 characters.max length 2500
-
CommunicationCheck boolean¶
Send true at least every cfg_communication_check_to_s seconds to signal that the client is alive, otherwise EVerest raises a CommunicationFault, which the next message clears. Send false to stop the check until the module restarts.
HeartBeatId integer¶
64bit unsigned integer. The id of every heartbeat increases by 1 and overflows when the maximum representable value is reached
Schemas from other APIs¶
CertificateHashDataInfo object defined in auth_consumer_API.yaml ↗¶
Contains the certificate information
Additional properties allowed.
-
hashAlgorithmstring required
Used algorithms for the hashes provided
enumSHA256SHA384SHA512 -
issuerNameHashstring required
Hashed value of the Issuer Distinguished Name
max length 128 -
issuerKeyHashstring required
Hashed value of the issuers public key
max length 128 -
serialNumberstring required
The serial number of the certificate
max length 40 -
responderURLstring required
This contains the responder URL
max length 512
CustomIdToken object defined in auth_consumer_API.yaml ↗¶
Type for a custom id token with a free-form type
Additional properties allowed.
-
valuestring required
Arbitrary value of the IdToken
min length 0max length 36 -
typestring required
Custom type of the token
min length 0max length 50
IdToken object defined in auth_consumer_API.yaml ↗¶
Type for an id token
Additional properties allowed.
-
valuestring required
Arbitrary value of the IdToken: This has to be printable case insensitive ascii
min length 0max length 36 -
Type of the token
enumCentraleMAIDMacAddressISO14443ISO15693KeyCodeLocalNoAuthorization -
additional_infoarray<object>
A list of additional custom id tokens than can be used for providing additional information for validation
-
itemsobject CustomIdToken ↗
Type for a custom id token with a free-form type
-
ProvidedIdToken object defined in auth_consumer_API.yaml ↗¶
Type for IdToken provided by auth token providers. Contains additional information about the IdToken like the source and purpose
Additional properties allowed.
-
request_idinteger
Id of the authorization request of this token. Could be used to put remoteStartId of OCPP2.0.1
-
Authorization type of the token.
enumOCPPRFIDAutochargePlugAndChargeBankCardmin length 2max length 32 -
connectorsarray<integer>
A list of connector ids to which the authorization can be assigned
-
itemsintegermin 1
-
-
prevalidatedboolean
Indicates that the id token is already validated by the provider
-
certificatestring
The X.509 certificated presented by EV and encoded in PEM format
max length 5500 -
iso15118CertificateHashDataarray<object>
Contains the information needed to verify the EV Contract Certificate via OCSP
min items 1max items 4-
itemsobject CertificateHashDataInfo ↗
An array of contract certificate infos
-
StopTransactionRequest object defined in evse_manager_consumer_API.yaml ↗¶
Request for a stop transaction containing the reason and an optional id tag
Additional properties allowed.
-
Reason for stopping the transaction
enumEmergencyStopEVDisconnectedHardResetLocalOtherPowerLossRebootRemoteSoftResetUnlockCommandDeAuthorizedEnergyLimitReachedGroundFaultLocalOutOfCreditMasterPassOvercurrentFaultPowerQualitySOCLimitReachedStoppedByEVTimeLimitReachedTimeoutReqEnergyTransferRejectedEVSEDisabled -
id_tagobject ProvidedIdToken ↗
Id tag that was used to stop the transaction. Only present if transaction was stopped locally.