11.3.2. board_supportΒΆ

Board support types

HardwareCapabilities:object
Hardware capability/limits
required: max_current_A_import, min_current_A_import, max_phase_count_import, min_phase_count_import, max_current_A_export, min_current_A_export, max_phase_count_export, min_phase_count_export, supports_changing_phases_during_charging
properties:
max_current_A_import:number
Maximum current (ampere) the hardware can handle (import from grid)
min_current_A_import:number
Minimum current (ampere) the hardware can use to charge. Values below may be set but may result in pause instead. (import from grid)
max_phase_count_import:integer
Max nr of phases the hardware can use (import from grid)
min_phase_count_import:integer
Minimum nr of phases the hardware can use (import from grid)
max_current_A_export:number
Maximum current (ampere) the hardware can handle (export to grid)
min_current_A_export:number
Minimum current (ampere) the hardware can use to charge. Values below may be set but may result in pause instead. (export to grid)
max_phase_count_export:integer
Max nr of phases the hardware can use (export to grid)
min_phase_count_export:integer
Minimum nr of phases the hardware can use (export to grid)
supports_changing_phases_during_charging:boolean
Indicates whether changing number of phases is supported during charging (true) or not (false)
Event:string
Event from ControlPilot signal/Relais/RCD
enum: CarPluggedIn, CarRequestedPower, PowerOn, PowerOff, CarRequestedStopPower, CarUnplugged, ErrorE, ErrorDF, ErrorRelais, ErrorRCD, ErrorRCD_DC, ErrorVentilationNotAvailable, ErrorOverCurrent, ErrorOverVoltage, ErrorUnderVoltage, ErrorMotorLock, ErrorOverTemperature, ErrorBrownOut, ErrorCablePP, ErrorEnergyManagement, ErrorNeutralPEN, ErrorCpDriver, EFtoBCD, BCDtoEF, PermanentFault, EvseReplugStarted, EvseReplugFinished
Telemetry:object
Other telemetry
required: temperature, fan_rpm, supply_voltage_12V, supply_voltage_minus_12V, rcd_current, relais_on
properties:
temperature:number
Current temperature of the EVSE in degree celsius
fan_rpm:number
RPM of the fan. 0 if off or no fan available.
supply_voltage_12V:number
Internal 12V supply voltage
supply_voltage_minus_12V:number
Internal -12V supply voltage
rcd_current:number
Residual current in mA
relais_on:boolean
true if power to the car is currently on, false if off