9.4. EnergyManager¶
This module is the global Energy Manager for all EVSE/Charging stations in this building
9.4.1. Additional documentation¶
Some example documentation for the module EnergyManager
.
9.4.2. Module Configuration¶
nominal_ac_voltage:number
default: 230.0
Nominal AC voltage to use to convert Ampere to Watt on AC
update_interval:integer
default: 1
Update interval for energy distribution [ms]
schedule_interval_duration:integer
default: 15
Duration of the schedule interval for forecast [min]
schedule_total_duration:integer
default: 24
Total duration of schedule forcast [h]
slice_ampere:number
default: 0.5
Ampere slice for trading. Lower values will give more even distribution but increase processing time [A].
slice_watt:number
default: 500
Watt slice for trading. Lower values will give more even distribution but increase processing time [A].
debug:boolean
default: False
Show debug output on command line.
9.4.3. Provides¶
main:energy_manager
Main interface of the energy manager
9.4.4. Requirements¶
energy_trunk:energy