11.1.14. EvseV2G¶
This module includes a DIN70121 and ISO15118-2 implementation provided by chargebyte GmbH
11.1.14.1. Module Configuration¶
device:string
default: eth0
Ethernet device used for HLC. Any local interface that has an ipv6 link-local and a MAC addr will work
supported_DIN70121:boolean
default: False
The EVSE supports the DIN SPEC
supported_ISO15118_2:boolean
default: True
The EVSE supports ISO15118-2
tls_security:string
default: prohibit
Controls how to handle encrypted communication
enum: prohibit, allow, force
terminate_connection_on_failed_response:boolean
default: False
Controls how to handle a failed response code of the EVSE. If true the V2G connection is terminated immediately on a failed response code, otherwise the EV is responsible for closing of the V2G communication session with SessionStop.
tls_key_logging:boolean
default: False
Enable/Disable the export of TLS session keys (pre-master-secret) during a TLS handshake. This log file can be used to decrypt TLS sessions. Note that this option is for testing and simulation purpose only
tls_key_logging_path:string
default: /tmp
Output directory for the TLS key log file
tls_timeout:integer
default: 15000
Set the TLS timeout in ms when establishing a tls connection
verify_contract_cert_chain:boolean
default: False
Specifies if the EVSE should verify the contract certificate chain locally.
auth_timeout_pnc:integer
default: 55
Defines how many seconds the EVSE should wait for authorization in PnC case, before the charging session is aborted. Write 0 if the EVSE should wait indefinitely for PnC authorization.
auth_timeout_eim:integer
default: 300
Defines how many seconds the EVSE should wait for authorization in EIM case, before the charging session is aborted. Write 0 if the EVSE should wait indefinitely for EIM authorization.
11.1.14.2. Provides¶
charger:ISO15118_charger
This module implements the ISO15118-2 implementation of an AC or DC charger
11.1.14.3. Requirements¶
security:evse_security