10.2.23. power_supply_DC¶
Interface for power supplies used for DC charging
10.2.23.1. Variables¶
voltage_current:object (power_supply_DC-VoltageCurrent)
Voltage/Current at the input/output
There is an extended definition for this object here.
mode:string (power_supply_DC-Mode)
Current mode. Published on change.
There is an extended definition for this object here.
fault_code:string (power_supply_DC-FaultCode)
Fault code. Published when fault happens.
There is an extended definition for this object here.
10.2.23.2. Commands¶
getCapabilities:object
Get capabilities of power supply
Result:object (power_supply_DC-Capabilities)
Capabilities
There is an extended definition for this object here.
setMode:void
Set operation mode of the bidirectional DC power supply
value:string (power_supply_DC-Mode)
Operation mode of power supply
There is an extended definition for this object here.
setExportVoltageCurrent:void
Set output target voltage limit. Must be within reported limits.
voltage:number
Output voltage in Volt
current:number
Output current limit in Ampere
setImportVoltageCurrent:void
Set minimal import voltage and current limit. Must be within reported limits.
voltage:number
Current will be drawn if input is above this voltage (in Volt)
current:number
Input current limit in Ampere