13.1.81. Winline¶
Driver for Winline ACDC power supply. Supports multiple Winline modules using CAN protocol either in fixed address mode or group discovery mode.
13.1.81.1. Module Configuration¶
can_device:string <optional>
default: “can0”
CAN interface name
module_addresses:string <optional>
default: “”
Module Addresses to use. If you have multiple PSUs, use individual addresses and list them comma separated, e.g. “1,2”.
group_address:integer <optional>
default: 0
Group address. Use this if your PSUs are using automatic allocation of the addresses. If you have multiple PSUs, set this number in accordance with the group dial setting of the PSUs you want to use. Can’t use module addresses and group addresses at the same time, if both are set, the module addresses will be used.
device_connection_timeout_s:integer <optional>
default: 15
Timeout in seconds to wait for a module to respond before considering it offline. CRITICAL SAFETY: Must be greater than module internal timeout to prevent overcurrent risk. Recommended: 15s.
conversion_efficiency_export:number <optional>
default: 0.95
Conversion efficiency of the export mode.
controller_address:integer <optional>
default: 240
Controller address defaults to 0xF0.
min_export_voltage_V:number <optional>
default: 50.0
Minimum export voltage limit (V)
max_export_voltage_V:number <optional>
default: 1000.0
Maximum export voltage limit (V)
min_export_current_A:number <optional>
default: 0.0
Minimum export current limit (A)
max_export_current_A:number <optional>
default: 133.3
Maximum export current limit (A) - will be updated by device rated values
power_state_grace_period_ms:integer <optional>
default: 2000
Grace period in milliseconds to wait before verifying power state changes
current_regulation_tolerance_A:number <optional>
default: 0.5
Current regulation tolerance (A)
peak_current_ripple_A:number <optional>
default: 2
Peak current ripple (A)
altitude_setting_m:integer <optional>
default: 1000
Working altitude setting in meters. This affects the power derating of the modules at high altitudes. Valid range: 1000-5000m. Default: 1000m (sea level).
input_mode:string <optional>
default: “AC”
Input mode for the power supply modules. AC mode for AC input, DC mode for DC input. This setting affects the internal configuration of the modules.
enum:
- AC
- DC
module_current_limit_point:number <optional>
default: 3.3325
Percentage of the rated current that the module will use as the current limit point (0.0-3.3325)
13.1.81.2. Provides¶
main:power_supply_DC
Main interface
config:
config: