13.1.64. UUGreenPower_UR1000X0¶
Driver for UUGreenPower_UR1000X0 ACDC power supply. Currently supports only one module.
13.1.64.1. Module Configuration¶
can_device:string <optional>
default: “can0”
CAN interface name
module_addresses:string <optional>
default: “0”
Module Addresses to use. Set to “0” for broadcast. Make sure to connect only one PSU on the CAN bus in broadcast mode, otherwise it will charge at a too high current (as every module will produce the full current the EV requests!) If you have multiple PSUs, use individual addresses and list them comma separated, e.g. “1,2”. Then it will share the current between these PSUs.
voltage_mode:integer <optional>
default: 0
Set to 0 for automatic switching, 1 for high voltage mode, 2 for low voltage mode
max_export_current_A:integer <optional>
default: 100
Maximum current that the PSU module can deliver. When using multiple PSUs in parallel, this refers to each individual PSU current capability.
max_export_power_W:integer <optional>
default: 40000
Maximum power that the PSU module can deliver. When using multiple PSUs in parallel, this refers to each individual PSU power capability.
13.1.64.2. Provides¶
main:power_supply_DC
Main interface
config:
config: