13.1.27. PhyVersoBSP¶
Driver module for Phytec PhyVerso EV Charging controller with Pionix MCU firmware
For a detailed handwritten documentation see here
13.1.27.1. Module Configuration¶
serial_port:string <optional>
default: “/dev/ttyUSB0”
Serial port the hardware is connected to
baud_rate:integer <optional>
default: 115200
Serial baud rate to use when communicating with the hardware
reset_gpio:integer <optional>
default: -1
Reset GPIO number to use to HW reset Yeti. If set <0 it is disabled.
mcu_config_file:string <optional>
default: “example_config_pionix.json”
config file that should be sent to the MCU
conn1_max_current_A_import:integer <optional>
default: 16
Maximum import current in amps
conn1_min_current_A_import:integer <optional>
default: 6
Minimum import current in amps
conn1_min_phase_count_import:integer <optional>
default: 3
Minimum phase count for import
conn1_max_phase_count_import:integer <optional>
default: 3
Maximum phase count for import
conn1_min_current_A_export:integer <optional>
default: 0
Minimum export current in amps
conn1_max_current_A_export:integer <optional>
default: 0
Maximum export current in amps
conn1_min_phase_count_export:integer <optional>
default: 3
Minimum phase count for export
conn1_max_phase_count_export:integer <optional>
default: 3
Maximum phase count for export
conn1_has_socket:boolean <optional>
default: False
Set to true if it has a socket, false if it has a permanently attached cable
conn1_dc:boolean <optional>
default: False
Set to true if it is for DC, false if it is AC
conn2_max_current_A_import:integer <optional>
default: 16
Maximum import current in amps
conn2_min_current_A_import:integer <optional>
default: 6
Minimum import current in amps
conn2_min_phase_count_import:integer <optional>
default: 3
Minimum phase count for import
conn2_max_phase_count_import:integer <optional>
default: 3
Maximum phase count for import
conn2_min_current_A_export:integer <optional>
default: 0
Minimum export current in amps
conn2_max_current_A_export:integer <optional>
default: 0
Maximum export current in amps
conn2_min_phase_count_export:integer <optional>
default: 3
Minimum phase count for export
conn2_max_phase_count_export:integer <optional>
default: 3
Maximum phase count for export
conn2_has_socket:boolean <optional>
default: False
Set to true if it has a socket, false if it has a permanently attached cable
conn2_dc:boolean <optional>
default: False
Set to true if it is for DC, false if it is AC
13.1.27.2. Provides¶
connector_1:evse_board_support
provides the board support interface to low level control the proximity and control pilots, relais and motor lock
connector_2:evse_board_support
provides the board support interface to low level control the proximity and control pilots, relais and motor lock
rcd_1:ac_rcd
RCD interface of the onboard RCD
rcd_2:ac_rcd
RCD interface of the onboard RCD
connector_lock_1:connector_lock
Lock interface
connector_lock_2:connector_lock
Lock interface
phyverso_mcu_temperature:phyverso_mcu_temperature
Temperatures from MCU
system_specific_data_1:generic_array
Opaque data blobs coming from connector 1
system_specific_data_2:generic_array
Opaque data blobs coming from connector 2