.. _everest_modules_YetiSimulator: ############# YetiSimulator ############# | SIL simulator for YETI hardware v1.0 ************************ Auto-Generated Reference ************************ Module Configuration ==================== | **connector_id**: *integer* | Connector id of the evse manager to which this simulator is connected to | **reset_powermeter_on_session_start**: *boolean* | *default: True* | Reset absolute powermeter readings to zero when CP changes from state A to B | **dummy_meter_value_send_on_transaction_start**: *boolean* | *default: True* | Send dummy meter start value blob on transaction start | **dummy_meter_value_blob_start**: *string* | *default: "test start value"* | Dummy meter value blob sent on transaction start to be used for testing | **dummy_meter_value_blob_stop**: *string* | *default: "test stop value"* | Dummy meter value blob sent on transaction stop to be used for testing | **ac_nominal_voltage**: *number* | *default: 230.0* | Nominal AC voltage between phase and neutral in Volt, reported per phase by the simulated power meter | **ac_nominal_frequency**: *number* | *default: 50.0* | Nominal AC grid frequency in Hertz, reported per phase by the simulated power meter | **ac_line_impedance_ohm**: *number* | *default: 0.5* | Line impedance in Ohm per phase between the grid and the simulated power meter. The reported phase voltage drops by ac_line_impedance_ohm * current, so the reported power is below ac_nominal_voltage * current while charging. Set to 0 to always report the nominal voltage. | **measurement_noise_percent**: *number* | *default: 1.0* | Peak amplitude in percent of the uniformly distributed random noise applied to the simulated voltages, currents, CP voltage, PP resistor and RCD current. Set to 0 for deterministic readings. The CP voltage is decoded with a +-1.1 V window, so values above a few percent break the CP state detection. | **frequency_noise_percent**: *number* | *default: 0.25* | Peak amplitude in percent of the uniformly distributed random noise applied to the simulated grid frequency. Set to 0 for a deterministic frequency reading. | **max_current_A_import**: *number* | *default: 32.0* | Maximum import current in amps reported as a hardware capability. The default matches a 32 A AC wallbox. DC configurations must raise this, since the energy manager derives the available power from max_current_A_import * max_phase_count_import * nominal_voltage_V and would otherwise cap a high-power DC supply at the AC-side figure. | **min_current_A_import**: *number* | *default: 6.0* | Minimum import current in amps reported as a hardware capability | **caps_min_current_A**: *integer* | *default: -1* | Minimal current on AC side reported in hardware capabilities. -1 means use min_current_A_import for import and the built-in default for export (0 A). | **caps_max_current_A**: *integer* | *default: -1* | Maximum current on AC side reported in hardware capabilities. -1 means use max_current_A_import for import and the built-in default for export (16 A). Provides ======== | **powermeter**: :ref:`powermeter ` | provides the Yeti Internal Power Meter | **temperature_sensor**: :ref:`temperature_sensor ` | Simulated internal temperature derived from powermeter load | **board_support**: :ref:`evse_board_support ` | provides the EVSE board support Interface to low level control pilot, relais, rcd, motor lock | **ev_board_support**: :ref:`ev_board_support ` | provides the EV board support Interface to low level control pilot, relais, rcd | **rcd**: :ref:`ac_rcd ` | Interface for the simulated AC RCD | **connector_lock**: :ref:`connector_lock ` | Interface for the simulated Connector lock ******** Metadata ******** Authors ======= | Cornelius Claussen | Tobias Marzell (Pionix GmbH) License ======= | https://opensource.org/licenses/Apache-2.0