.. _everest_modules_EvseManager: ########### EvseManager ########### | EVSE Manager. Grid side power meter: Will be used for energy management. Will also be used for billing if no car side power meter connected. Car side powermeter: Will be used for billing if present. ************************* Handwritten Documentation ************************* .. include:: index.inc ************************ Auto-Generated Reference ************************ Module Configuration ==================== | **connector_id**: *integer* | ID of this EVSE within the charging station, according to the 3-tier model of OCPP (charging station > EVSE > connector). The parameter is named connector_id for backwards compatibility reasons only; it does not identify a connector. | **connector_type**: *string* | *default: "Unknown"* | The connector type of this evse manager (/evse_manager#/ConnectorTypeEnum) | **evse_id**: *string* | *default: "DE*PNX*E1234567*1"* | EVSE ID that uniquely identifies this EVSE, e.g. DE*PNX*E1234567*1. It has a special format that includes the country code, the operator id and a power outlet id (eMI3 format, normatively specified in ISO 15118-2 Annex H) and is sent as the EVSEID field in ISO 15118 messages. | **evse_id_din**: *string* | *default: "49A80737A45678"* | EVSE ID used for DIN 70121 sessions (format according to DIN SPEC 91286, hexBinary-encoded), e.g. 49A80737A45678 | **payment_enable_eim**: *boolean* | *default: True* | Set to true to enable EIM (e.g. RFID card or mobile app) authorization | **payment_enable_contract**: *boolean* | *default: True* | Set to true to enable contract (aka plug and charge) authorization | **ac_nominal_voltage**: *number* | *default: 230* | Nominal AC voltage between phase and neutral in Volt | **ac_nominal_frequency**: *number* | *default: 50* | Nominal AC grid frequency in Hz, normally 50 or 60. Advertised for ISO 15118-20 AC DER as the GridNominalFrequency the EV adopts, so it must match the installation. It does not scale the grid code frequency-trip curves, which are in absolute Hz. | **ac_max_reactive_power**: *number* | *default: 0* | Maximum EVSE reactive power in var; passed to the HLC stack as the AC_DER_IEC de-normalization base. 0 means the EVSE has no reactive-power capability. | **ev_receipt_required**: *boolean* | *default: False* | Unsupported: request receipt from EV with HLC | **session_logging**: *boolean* | *default: False* | Enable/Disable session log file output | **session_logging_path**: *string* | *default: "/tmp"* | Output directory for session log files | **session_logging_xml**: *boolean* | *default: True* | Include full XML messages for HLC in the console output of the session log. The session log files always contain the full messages. | **session_logging_console**: *boolean* | *default: True* | Also write session log entries to the EVerest log (console). If disabled, session log entries are only written to the session log files and published via MQTT. | **has_ventilation**: *boolean* | *default: True* | Allow ventilated charging or not | **charge_mode**: *string* | *default: "AC"* | Select charging mode | enum: | - AC | - DC | **supported_iso_ac_bpt**: *boolean* | *default: False* | Set to true if ISO15118-20 AC BPT is supported and should be offered to the EV | **iso15118_der_flavor**: *string* | *default: "NONE"* | Which ISO 15118-20 Amendment 1 AC DER annex to advertise: IEC is Annex L, SAE is Annex M, NONE advertises neither. The two annexes are mutually exclusive per EVSE, so at most one AC DER energy transfer mode is ever advertised. Takes effect only when DER availability has been asserted for this EVSE and the EVSE is export-capable; SAE additionally needs the AC parameters. grid_support DER directives reach the IEC control functions only, so a SAE EVSE runs the inert default grid code. | enum: | - NONE | - IEC | - SAE | **ac_hlc_enabled**: *boolean* | *default: False* | Enable or disable HLC (aka ISO15118) for AC mode | **ac_hlc_use_5percent**: *boolean* | *default: True* | If set to true, start with 5% PWM if HLC is enabled on AC. If set to false, start with X1. Note that almost no EV will perform SLAC/HLC on X1. Recommendation is to set this to true. | **ac_enforce_hlc**: *boolean* | *default: False* | Combine with 5percent option to really enforce HLC even with EIM. ISO15118-3 forbids the usage of 5% if Auth happens before plugin, but most EVs will not perform HLC with nominal PWM. For the home use case (always authorized or auth before plugin) it may still be desirable to use HLC e.g. for better energy management. In this case you can use this option, but be aware that EVs that do not support HLC may take a long time to start (or never start) charging. This mode is not ISO15118-2/-3 compliant. Do not use for public charging stations. | **ac_limit_slac_init_retries**: *boolean* | *default: True* | Limit the SLAC matching retries as required by ISO15118-3. With 5% PWM ([V2G3-M06-07], Figure 9): if no SLAC request arrives within TT_EVSE_SLAC_init, the EVSE signals E/F for T_step_EF and returns to 5% PWM at most C_sequ_retry (2) times per plug-in. At the next timeout it signals E/F once more and keeps 5% off for the rest of the session: X1 while waiting for authorization (an EIM can still start basic charging), nominal PWM once authorized, also with ac_enforce_hlc. A running HLC session is not affected. Each retry is one error routine request from the SLAC module; with its reset_instead_of_fail option one request spans two TT_EVSE_SLAC_init. With nominal PWM or X1 ([V2G3-A09-13]), a failed matching is not retried and the PWM stays as it is. If false, every failed matching is retried with E/F until the EV is unplugged, also with nominal PWM. | **ac_with_soc**: *boolean* | *default: False* | Special mode that switches between AC and DC charging to get SoC percentage with AC charging | **reinit_duration_ms**: *integer* | *default: 3000* | Duration in milliseconds of the reinit state before going back to normal operation | **reinit_method**: *string* | *default: "CPStateF"* | Configures the control pilot behaviour during reinitialization of the connection to the EV. Reinitialization may be used to recover from an unsuccessful PLC link setup, wake up the EV, or switch between HLC and basic AC charging in AC with SoC mode. | CPStateE: set CP to state E (0 V) to simulate an unplug. This requires BSP support for CP state E. | CPStateF: set CP to state F (-12 V) to signal a temporary unavailability. | CPStateX1: keep CP powered with 100% duty cycle to signal that no energy is available. | enum: | - CPStateE | - CPStateF | - CPStateX1 | **internal_over_voltage_duration_ms**: *integer* | *default: 400* | Time in milliseconds the internal software over voltage monitor waits before raising MREC5 once the measured voltage exceeds the negotiated limit. | **dbg_hlc_auth_after_tstep**: *boolean* | *default: False* | Special mode: send HLC auth ok only after t_step_XX is finished (true) or directly when available (false) | **dc_isolation_voltage_V**: *integer* | *default: 0* | Override DC voltage used to test isolation in CableCheck. Default is 0, which means the voltage will be determined according to IEC 61851-23 (2023) CC.4.1.2 | **cable_check_wait_number_of_imd_measurements**: *integer* | *default: 1* | Amount of isolation measurement samples to collect before the value can be trusted. This does not average, it will evaluate the last measurement. Some IMDs (e.g. from Bender) need to measure for 10s to really get a trustable result. In this case, at 1 Hz sample rate, specify 10 samples here. If the self test includes the isolation resistance checking you may also set this to 0. | **cable_check_enable_imd_self_test**: *boolean* | *default: True* | Enable self testing of IMD in cable check with the voltage calculated from ev_max_voltage and with relays closed. This is required e.g. for Bender IMDs which also perform an isolation measurement during the self test. A self test is required for IEC 61851-23 (2023) compliance. | **cable_check_enable_imd_self_test_relays_open**: *boolean* | *default: False* | Enable self testing of IMD at the beginning of cable check where the relays may still be open. The voltage is set by the cable_check_relays_open_voltage_V config option and may differ from the voltage that is later used to perform the isolation resistance sample. cable_check_wait_number_of_imd_measurements needs to be >=1 in this case as no isolation resistance checking can be performed at this stage. If both this option and cable_check_enable_imd_self_test are enabled, the selftest is started with relays open, but the result is captured later on, as it would be with the regular selftest sequence. In this case the powersupply will remain active and transition to the regular cable check voltage. A self test is required for IEC 61851-23 (2023) compliance. | **cable_check_relays_open_voltage_V**: *integer* | *default: 48* | Voltage to set for the self test using cable_check_enable_imd_self_test_relays_open option. | **cable_check_relays_closed_timeout_s**: *integer* | *default: 5* | Timeout in seconds to wait for the relays to close at the beginning of cablecheck. Normally they should be closed right away, but when cable_check_enable_imd_self_test_relays_open option, the relays may close may be delayed by the self test. | **cable_check_measurement_timeout_s**: *integer* | *default: 2* | Time in seconds to wait for a voltage measurement from the power supply during cablecheck before logging that the measurement stream has stalled. A gap does not fail the cablecheck by itself: waiting continues until the overall voltage timeout of 10 seconds expires, so a measurement source that goes briefly silent (e.g. a power meter polled over the network) does not abort an otherwise healthy cablecheck. Raise this if the measurement source is known to be slower than the default. | **cable_check_wait_below_60V_before_finish**: *boolean* | *default: True* | Switch off power supply and wait until output voltage drops below 60V before cable check is finished. Note: There are different versions of IEC 61851-23:2023 in the wild with the same version number but slightly different content. The IEC was correcting mistakes _after_ releasing the document initially without tagging a new version number. Some early versions require to wait for the output voltage to drop below 60V in CC.4.1.2 (last sentence). Later versions do not have that requirement. The later versions are correct and should be used according to IEC. Both settings (true and false) are compliant with the correct version of IEC 61851-23:2023. Set to true when: | - the power supply has no active discharge, and lowering the voltage with no load takes a very long time. In this case | this option usually helps to ramp the voltage down quickly by switching it off. It will be switched on again in precharge. | Also, some EVs switch their internal relay on at a too high voltage when the voltage is ramped down directly from cablecheck voltage to precharge voltage, | so true is the recommended default. | Set to false when: | - the power supply has active discharge and can ramp down quickly without a switch off (by just setting a lower target voltage). | This may save a few seconds as it avoids unnecessary voltage down and up ramping. | **hack_skoda_enyaq**: *boolean* | *default: False* | Skoda Enyaq requests DC charging voltages below its battery level or even below 0 initially. Set to true to enable dirty workaround. | **hack_present_current_offset**: *integer* | *default: 0* | Adds an offset [A] to the present current reported to the car on HLC. Set to 0 unless you really know what you are doing. | **ev_side_voltage_source**: *string* | *default: "powermeter_car_side"* | Voltage measurement reported to the EV as EVSE present voltage during DC welding detection, from PowerDelivery(Stop) until SessionStop. It has to be the side B voltage at the vehicle connector with the EVSE contactors open (IEC 61851-23:2023 CC.7.6.17), so the selected source must measure on the EV side of the EVSE output contactors; a meter or monitor between the power supply and the contactors, like the power supply itself, sees only the power supply output once the contactors are open. If the selected source is not connected, the next connected one in the order powermeter_car_side, over_voltage_monitor, power_supply is used and a warning is printed; isolation_monitor is only used when configured. Outside welding detection the power supply measurement is always reported. The over voltage monitor and the isolation monitor keep running until welding detection ends. For the isolation monitor this deviates from IEC 61851-23:2023 Table CC.9 t103, which requires the EVSE IMD to be disabled when side B is disabled, and the EV may enable its own IMD (t104): only use it with an IMD that measures the voltage without its insulation test. | enum: | - powermeter_car_side | - over_voltage_monitor | - isolation_monitor | - power_supply | **hack_pause_imd_during_precharge**: *boolean* | *default: False* | Disable IMD at the end of CableCheck and re-enable when current is flowing in CurrentDemand. Some DCDC power supplies do not start current flow when insulation measurement is active. Set to true to enable dirty workaround for some IMD hardware. | **hack_allow_bpt_with_iso2**: *boolean* | *default: False* | Hack. Allow bidirectional power transfer with DIN spec and ISO-2. Currents communicated on HLC will always be positive but power supply may actually discharge the car. | **hack_simplified_mode_limit_10A**: *boolean* | *default: False* | Limit PWM to 10A if EV uses simplified charging mode. Set to false to be compliant with IEC61851-1:2019 section A.2.3. It is the responsibility of the EV to limit to 10A according to the norm. Enable this option to deviate from the norm and limit from the EVSE side. | **autocharge_use_slac_instead_of_hlc**: *boolean* | *default: False* | Use slac ev mac address for autocharge instead of EVCCID from HLC | **enable_autocharge**: *boolean* | *default: False* | Enables Autocharge (i.e. Mac address for authorization). Disabled by default as PnC should be used instead. | **logfile_suffix**: *string* | *default: "session_uuid"* | Use the string given for the log folder name. Special string session_uuid will be replaced with session uuid. | **soft_over_current_tolerance_percent**: *number* | *default: 10.0* | Allow for N percent over current in soft over current checking during AC charging. | **soft_over_current_measurement_noise_A**: *number* | *default: 0.5* | Set current measurement noise. Added to limit as an offset to avoid false triggers. | **hack_fix_hlc_integer_current_requests**: *boolean* | *default: False* | Some cars request only integer ampere values during DC charging. For low power DC charging that means that they charge a few hundred watts slower then needed. If enabled, this will charge at full power if the difference between EV requested current (integer) and HLC current limit is less then 1.0 | **disable_authentication**: *boolean* | *default: False* | Do not wait for authorization from Auth module, offer a free service. Start charging immediately after plug in. Do not use with Auth manager or OCPP, this option is only to allow charging with a standalone EvseManager that is not connected to an Auth manager. Use DummyTokenProvider/Validator when testing with Auth module and/or OCPP. | **sae_j2847_2_bpt_enabled**: *boolean* | *default: False* | Enable SAE J2847 2 V2G or V2H mode | **sae_j2847_2_bpt_mode**: *string* | *default: "V2G"* | SAE J2847 2 BPT mode | enum: | - V2H | - V2G | **request_zero_power_in_idle**: *boolean* | *default: False* | "true: In Idle mode (no car connected) and while charging is paused by the EVSE for a user pause or an error, request 0A from" "energy management. In installations with many charging stations this should be set to allow the power to be distributed to the" "chargers that are connected to a car. A pause because of missing energy keeps requesting energy so that charging can resume." "false: Request the normal current even if no car is connected. This speeds up the start of charging on AC BASIC charging as" "EvseManager does not need to wait for energy from the energy manager after plug in." | **external_ready_to_start_charging**: *boolean* | *default: False* | Enable the external ready to start charging signal that delays charging ready until it has been received | **uk_smartcharging_random_delay_enable**: *boolean* | *default: False* | "true: enable random_delays on start up, false: disable random delays on startup." "They can also be enabled/disabled during runtime on the random_delay implementation." | **uk_smartcharging_random_delay_max_duration**: *integer* | *default: 600* | "Start up value for the maximum duration of a random delay." "Can be modified during runtime on the random_delay implementation." | **uk_smartcharging_random_delay_at_any_change**: *boolean* | *default: True* | "True: use random delays on any current change during charging. False: Only use if current is reduced to zero or increased from zero." | **initial_meter_value_timeout_ms**: *integer* | *default: 5000* | This timeout in ms defines for how long the EvseManager waits for an initial meter value from a powermeter before it becomes ready to start charging. If configured to 0, the EvseManager will not wait for an initial meter value before it becomes ready to start charging. | **switch_3ph1ph_delay_s**: *integer* | *default: 10* | Wait for n seconds when switching between 3ph/1ph mode. | **switch_3ph1ph_cp_state**: *string* | *default: "X1"* | CP state to use for switching. WARNING: Some EVs may be permanently destroyed when switching from 1ph to 3ph. It is the responsibiltiy of the evse_board_support implementation to ensure the EV is capable of performing the switch. If it is not, the capabilities must set the supports_changing_phases_during_charging to false. Phase switching is only possible in basic charging mode. | enum: | - X1 | - E | - F | **soft_over_current_timeout_ms**: *integer* | *default: 7000* | Allow for over current to be present for N ms in soft over current checking during AC charging. | **soft_over_current_stale_data_warning_ms**: *integer* | *default: 5000* | Diagnostics only: warn if the current measurements used for soft over current checking during AC charging have not been updated for more than N ms, which may indicate a frozen power meter or a broken communication link. The measurements are still used as-is. Increase this value for power meters with slow update intervals. Set to 0 to disable the warning. | **lock_connector_in_state_b**: *boolean* | *default: True* | Indicates if the connector lock should be locked in state B. If set to false, connector will remain unlocked in CP state B and this violates IEC61851-1:2019 D.6.5 Table D.9 line 4 and should not be used in public environments! This feature is deprecated. | **unlock_when_deauthorized**: *boolean* | *default: False* | Indicates if the connector lock should be locked in state B/C regardless of if a user authorized. If set to true, connector will remain unlocked in CP state B/C if the relays are open and no user is authorized. This violates IEC61851-1:2019 D.6.5 Table D.9 line 4 and should not be used in public environments! | **keep_cable_locked**: *boolean* | *default: False* | Captive cable mode for AC sockets with a connector lock (fleet/private use): keep the cable locked in the socket whenever a plug is present, in every CP state - including state A with no EV attached. The only way to unlock is the force_unlock command (e.g. triggered by OCPP UnlockConnector); the connector then stays unlocked until the cable is removed, and the next plug insertion locks it again. An engaged lock is latched: losing plug presence without a preceding force_unlock (e.g. the PP contact opening while the plug is pulled against the lock pin) does not release it. Takes precedence over lock_connector_in_state_b and unlock_when_deauthorized. Can be changed at runtime via the configuration service (applied immediately, no restart required). Requires a BSP that publishes ac_pp_ampacity on every change, also outside of charging sessions, and once at startup with the current value (only needed when this option is used). Only applies to AC sockets with a connector lock: ignored with charge_mode other than AC, without a connector lock or when the BSP reports a fixed attached cable, and setting it at runtime is then rejected (a fixed cable is only known once the BSP capabilities arrived; the mode activates then). The normal locking rules still apply on top of it. | mutability:ReadWrite | **keep_cable_locked_lock_delay_ms**: *integer* | *default: 500* | Captive cable mode only: delay in milliseconds between detecting a plug (ac_pp_ampacity becomes non-zero) and engaging the connector lock. Gives the plug time to seat fully before the lock pin extends, so a lock triggered on the first Proximity Pilot contact cannot jam a half-inserted plug. If the plug is pulled back out again within the delay, no lock is engaged. Set to 0 to lock immediately. The effective delay is rounded up to the next multiple of 500 ms (timer resolution). | **state_F_after_fault_ms**: *integer* | *default: 300* | Set state F after any fault that stops charging for the specified time in ms while in Charging mode (CX->F(300ms)->C1/B1). When a fault occurs in state B2, no state F is added (B2->B1 on fault). Some (especially older hybrid vehicles) may go into a permanent fault mode once they detect state F, in this case EVerest cannot recover the charging session if the fault is cleared. In this case you can set this parameter to 0, which will avoid to use state F in case of a fault and only disables PWM (C2->C1) while switching off power. This will violate IEC 61851-1:2017 however. The default is 300ms as the minimum suggested by IEC 61851-1:2017 Table A.5 (description) to be compliant. This setting is only active in BASIC charging mode. | **fail_on_powermeter_errors**: *boolean* | *default: True* | Set the EVSE Manager to an inoperative state if the powermeter requirement is configured and has reported errors | **raise_mrec9**: *boolean* | *default: False* | Allows to configure if an MREC9 authorization timeout error shall be raised by this module in case an authorization timeout occurs. It is recommended to disable it if OCPP1.6 is used. | **sleep_before_enabling_pwm_hlc_mode_ms**: *integer* | *default: 500* | Sleep before the PWM signal is updated in HLC mode. Teslas are really fast with sending the first slac packet after enabling PWM, so the sleep allows SLAC to be ready for it. Some EV testers have issues with a value >= 1000ms, although ISO15118 or IEC61851 does not specify a timeout. | **central_contract_validation_allowed**: *boolean* | *default: False* | Used for ISO15118 plug and charge: If false, contract shall not be present in PaymentOptionList. If true, contract may be present in PaymentOptionList if TLS is used. | **contract_certificate_installation_enabled**: *boolean* | *default: True* | Used for ISO15118 plug and charge: Indicates if the charger supports contract CertificateInstall and CertificateUpdate | **inoperative_error_use_vendor_id**: *boolean* | *default: False* | When raising evse_manager/Inoperative use the vendor ID from the original cause | **voltage_plausibility_max_spread_threshold_V**: *number* | *default: 50.0* | Maximum allowed spread (max-min) in volts between voltage measurements from different sources (power supply, powermeter, isolation monitor, over voltage monitor) before a voltage plausibility fault is triggered. During DC charging, if the spread exceeds this threshold for the configured duration, a fault is raised. | **voltage_plausibility_fault_duration_ms**: *integer* | *default: 30000* | Duration in milliseconds for which the spread must exceed the threshold before a voltage plausibility fault is raised. A duration of 0 ms means that a fault will be raised immediately when the threshold is exceeded. | **session_id_type**: *string* | *default: "UUID"* | Type to use for generation of session ids. UUID: 36 characters UUIDs UUID_BASE64: 22 characters base64 encoded uuids SHORT_BASE64: 16 characters base64 encoded ids | enum: | - UUID | - UUID_BASE64 | - SHORT_BASE64 | **zero_power_ignore_pause**: *boolean* | *default: True* | If no energy is available the charger can signal a pause to the car before cable check. With this option the charger ignores that and continues as if energy were available. This is not standard compliant! As of today most EVs do not handle the pause signal correctly causing the session to be terminated and not allowing to start charging again when energy is available. The default of this value is true, allowing the session to proceed until the charge loop. Terminating the session in the charge loop when no energy is available is handled more gracefully by most EVs and allows to start charging again when energy is available without the need of unplugging and plugging again. | **zero_power_allow_ev_to_ignore_pause**: *boolean* | *default: False* | If no energy is available the charger can signal a pause to the car before cable check. With this option, the charger ignores that the ev goes to the energy phase instead of pausing the session. This is not standard compliant! | **bpt_channel**: *string* | *default: "None"* | Type of installed/uninstalled power transfer channel | enum: | - None | - Unified | - Separated | **bpt_generator_mode**: *string* | *default: "None"* | Power converter behavior | enum: | - None | - GridFollowing | - GridForming | **bpt_grid_code_island_method**: *string* | *default: "None"* | Active/inactive islanding detection method. Only for AC. | enum: | - None | - Active | - Passive | **hlc_charge_loop_without_energy_timeout_s**: *integer* | *default: 5* | Timeout (s) to allow HLC charge loop to continue without available energy; when exceeded, the HLC session is stopped and PWM is disabled until energy returns. If set too long, some EVs stop the session on their own. Then it cannot be resumed when energy is available again. | **dc_ramp_ampere_per_second**: *integer* | *default: 25* | Maximum ampere per second limit for up/down ramping of current in charging loop. | **enable_nodered_interface**: *boolean* | *default: False* | Enable the external MQTT interface to the Node-RED debug UI (topics below everest_external/nodered//). This publishes powermeter and state updates and subscribes to UI commands (enable/disable/pause/resume/phase switch). Only needed when the Node-RED simulation/debug UI is used. | **phase_rotation_grid_side**: *string* | *default: "RST"* | Corrects for a physical L1/L2/L3 wiring rotation at the grid side powermeter by remapping its per-phase voltage/current/power/energy/VAR values before they are used in energy_flow_request.energy_usage_root. RST means no rotation, i.e. reported L1/L2/L3 already matches grid L1/L2/L3. STR means reported L1 is grid L2, reported L2 is grid L3, reported L3 is grid L1. TRS means reported L1 is grid L3, reported L2 is grid L1, reported L3 is grid L2. | enum: | - RST | - STR | - TRS | **debug_emit_cp_state_hpav_frames**: *boolean* | *default: False* | Debugging aid. Emit a HomePlug AV STP_CPSTATE.IND frame (ethertype 0x88E1, ST/IoTecha vendor MME) on debug_cp_state_hpav_device whenever the measured CP state or the commanded PWM duty cycle changes. Wireshark and the dsV2Gshark plugin decode these frames, so a packet capture of the PLC interface shows the CP state next to SLAC and ISO 15118 traffic. Sending raw Ethernet frames needs the CAP_NET_RAW capability for this module. Do not enable in production. | **debug_cp_state_hpav_device**: *string* | *default: ""* | Network interface the CP state frames are sent on when debug_emit_cp_state_hpav_frames is true, typically the PLC modem interface also used by the SLAC module. Provides ======== | **evse**: :ref:`evse_manager ` | This is the main evsemanager interface | **energy_grid**: :ref:`energy ` | This is the tree leaf interface to build the energy supply tree | **token_provider**: :ref:`auth_token_provider ` | Provides authtokens for autocharge or plug and charge | **random_delay**: :ref:`uk_random_delay ` | Provides control over UK smart charging regulation random delay feature | **dc_external_derate**: :ref:`dc_external_derate ` | Provides DC external derating capabilities Requirements ============ | **bsp**: :ref:`evse_board_support ` 1 | **ac_rcd**: :ref:`ac_rcd ` 0..1 | **connector_lock**: :ref:`connector_lock ` 0..1 | **powermeter_grid_side**: :ref:`powermeter ` 0..1 | **powermeter_car_side**: :ref:`powermeter ` 0..1 | **slac**: :ref:`slac ` 0..1 | **hlc**: :ref:`ISO15118_charger ` 0..1 | **imd**: :ref:`isolation_monitor ` 0..1 | **over_voltage_monitor**: :ref:`over_voltage_monitor ` 0..1 | **powersupply_DC**: :ref:`power_supply_DC ` 0..1 | **store**: :ref:`kvs ` 0..1 ******** Metadata ******** Authors ======= | Cornelius Claussen | Anton Woellert License ======= | https://opensource.org/licenses/Apache-2.0