11.2.29. power_supply_DC¶
Interface for power supplies used for DC charging
11.2.29.1. Variables¶
voltage_current:object (power_supply_DC-VoltageCurrent)
Voltage/Current at the input/output
There is an extended definition for this object here.
mode:string (power_supply_DC-Mode)
Current mode. Published on change.
There is an extended definition for this object here.
fault_code:string (power_supply_DC-FaultCode)
Fault code. Published when fault happens.
There is an extended definition for this object here.
11.2.29.2. Commands¶
getCapabilities:object
Get capabilities of power supply
Result:object (power_supply_DC-Capabilities)
Capabilities
There is an extended definition for this object here.
setMode:void
Set operation mode of the bidirectional DC power supply
value:string <required> (power_supply_DC-Mode)
Operation mode of power supply
There is an extended definition for this object here.
setExportVoltageCurrent:void
Set output target voltage limit. Must be within reported limits.
voltage:number <required>
Output voltage in Volt
current:number <required>
Output current limit in Ampere
setImportVoltageCurrent:void
Set minimal import voltage and current limit. Must be within reported limits.
voltage:number <required>
Current will be drawn if input is above this voltage (in Volt)
current:number <required>
Input current limit in Ampere