:orphan: .. _everest_types_units_signed: ############ units_signed ############ Unit types .. _units_signed-SignedMeterValue: | **SignedMeterValue**: *object* | Representation of a signed meter value | properties: | **signed_meter_data**: *string* | Signed meter data (encoded in a string representation with eg. Base64) | **signing_method**: *string* | Method used to create the signature | **encoding_method**: *string* | Method used to encode the meter values before signing them | **public_key**: *string* | Public key (encoded in a string representation with eg. Base64) | **timestamp**: *string* | Timestamp of measurement | format:date-time .. _units_signed-Current: | **Current**: *object* | Current in Ampere | properties: | **DC**: *object* (:ref:`units_signed-SignedMeterValue `) | DC current | **L1**: *object* (:ref:`units_signed-SignedMeterValue `) | AC L1 value only | **L2**: *object* (:ref:`units_signed-SignedMeterValue `) | AC L2 value only | **L3**: *object* (:ref:`units_signed-SignedMeterValue `) | AC L3 value only | **N**: *object* (:ref:`units_signed-SignedMeterValue `) | AC Neutral value only .. _units_signed-Voltage: | **Voltage**: *object* | Voltage in Volt | properties: | **DC**: *object* (:ref:`units_signed-SignedMeterValue `) | DC voltage | **L1**: *object* (:ref:`units_signed-SignedMeterValue `) | AC L1 value only | **L2**: *object* (:ref:`units_signed-SignedMeterValue `) | AC L2 value only | **L3**: *object* (:ref:`units_signed-SignedMeterValue `) | AC L3 value only .. _units_signed-Frequency: | **Frequency**: *object* | AC only: Frequency in Hertz | properties: | **L1**: *object* (:ref:`units_signed-SignedMeterValue `) | AC L1 value | **L2**: *object* (:ref:`units_signed-SignedMeterValue `) | AC L2 value | **L3**: *object* (:ref:`units_signed-SignedMeterValue `) | AC L3 value .. _units_signed-Power: | **Power**: *object* | Instantaneous power in Watt. Negative values are exported, positive values imported Energy. | properties: | **total**: *object* (:ref:`units_signed-SignedMeterValue `) | DC / AC Sum value | **L1**: *object* (:ref:`units_signed-SignedMeterValue `) | AC L1 value only | **L2**: *object* (:ref:`units_signed-SignedMeterValue `) | AC L2 value only | **L3**: *object* (:ref:`units_signed-SignedMeterValue `) | AC L3 value only .. _units_signed-Energy: | **Energy**: *object* | Energy in Wh. | properties: | **total**: *object* (:ref:`units_signed-SignedMeterValue `) | DC / AC Sum value (which is relevant for billing) | **L1**: *object* (:ref:`units_signed-SignedMeterValue `) | AC L1 value only | **L2**: *object* (:ref:`units_signed-SignedMeterValue `) | AC L2 value only | **L3**: *object* (:ref:`units_signed-SignedMeterValue `) | AC L3 value only .. _units_signed-ReactivePower: | **ReactivePower**: *object* | Reactive power VAR | properties: | **total**: *object* (:ref:`units_signed-SignedMeterValue `) | VAR total | **L1**: *object* (:ref:`units_signed-SignedMeterValue `) | VAR phase A | **L2**: *object* (:ref:`units_signed-SignedMeterValue `) | VAR phase B | **L3**: *object* (:ref:`units_signed-SignedMeterValue `) | VAR phase C