13.3.19. powermeter

Powermeter types

TransactionReq:object
Required input parameter for starting an OCMF transaction. These values will be included in the signed OCMF packet.
properties:
evse_id:string <required>
Id of this EVSE
transaction_id:string <required>
OCPP transaction UUID
identification_status:string <required> (powermeter-OCMFUserIdentificationStatus)
OCMF Identification Status (IS): General status for user assignment
There is an extended definition for this object here.
identification_level:string <optional> (powermeter-OCMFIdentificationLevel)
OCMF Identification Level (IL): Encoded overall status of the user assignment
There is an extended definition for this object here.
identification_flags:array <required>
OCMF Identification Flags (IF): Detailed statements about the user assignment, represented by one or more identifiers

There is an extended definition for this object here.

identification_type:string <required> (powermeter-OCMFIdentificationType)
OCMF Identification Type (IT): Type of identification data
There is an extended definition for this object here.
identification_data:string <optional>
OCMF Identification Data (ID): The actual identification data e.g. a hex-coded UID according to ISO 14443.
tariff_text:string <optional>
A textual description used to identify a unique tariff. This field is intended for the tariff designation in “Direct Payment” use case.
TransactionRequestStatus:string
Status of a transaction start or stop request.
enum:
- OK
- NOT_SUPPORTED
- UNEXPECTED_ERROR
TransactionStartResponse:object
Return value when a transaction is started.
properties:
status:object <required> (powermeter-TransactionRequestStatus)
Response status that indicates whether the transaction start request could successfully be performed.
There is an extended definition for this object here.
error:string <optional>
If status is not OK, a verbose error message.
transaction_min_stop_time:string <optional>
Earliest point in time the started transaction can be stopped again (if a minimum duration is required by the meter); yields a RFC3339 timestamp.
format:date-time
transaction_max_stop_time:string <optional>
Deadline for the transaction to be stopped again (if a minimum duration is required by the meter); yields a RFC3339 timestamp.
format:date-time
TransactionStopResponse:object
Report returned when a signed transaction is requested to stop. If successful, includes the signed meter value object. In case of an error, an additional error message can be provided.
properties:
status:object <required> (powermeter-TransactionRequestStatus)
Response status that indicates whether the transaction stop request could successfully be performed.
There is an extended definition for this object here.
start_signed_meter_value:object <optional> (units_signed-SignedMeterValue)
The signed meter value report for start of transaction. Needs to be filled if meter provides separate values for start and stop.
There is an extended definition for this object here.
signed_meter_value:object <optional> (units_signed-SignedMeterValue)
The signed meter value report of the stopped transaction. Must be provided if status is OK.
There is an extended definition for this object here.
error:string <optional>
If status is not OK, a verbose error message.
OCMFIdentificationLevel:string
NONE: There is no user assignment. The other data for user assignment have no significance. HEARSAY: The assignment is unsecured; e.g. by reading an RFID UID. TRUSTED: The mapping can be trusted to some extent, but there is no absolute reliability. Example: Authorization by backend. VERIFIED: The assignment has been verified by the signature component and special measures. CERTIFIED: The assignment was verified by the signature component using a cryptographic signature that certifies the assignment. SECURE: The mapping was established by a secure feature (e.g. secure RFID card, ISO 15118 with plug and charge, etc.). MISMATCH: Error; UIDs do not match. INVALID: Error; certificate not correct (check negative). OUTDATED: Error; referenced trust certificate expired. UNKNOWN: Certificate could not be successfully verified (no matching trust certificate found).
enum:
- NONE
- HEARSAY
- TRUSTED
- VERIFIED
- CERTIFIED
- SECURE
- MISMATCH
- INVALID
- OUTDATED
- UNKNOWN
OCMFIdentificationFlags:string
RFID_NONE: No assignment via RFID RFID_PLAIN: Assignment via external RFID card reader RFID_RELATED: Assignment via protected RFID card reader RFID_PSK: A previously known shared key (pre-shared key) was used, e.g. with a secured RFID card. OCPP_NONE: No user assignment by OCPP OCPP_RS: Assignment by OCPP RemoteStart method OCPP_AUTH: Assignment by OCPP Authorize method OCPP_RS_TLS: Assignment by OCPP RemoteStart method, obtained via a secured TLS connection. OCPP_AUTH_TLS: Assignment by OCPP Authorize method, obtained via a secured TLS connection. OCPP_CACHE: Assignment by authorization cache of OCPP OCPP_WHITELIST: Assignment by whitelist from OCPP OCPP_CERTIFIED: A certificate of the backend was used which certifies the user mapping. ISO15118_NONE: no user assignment by ISO 15118 ISO15118_PNC: Plug & Charge was used PLMN_NONE: no user assignment PLMN_RING: call PLMN_SMS: short message
enum:
- RFID_NONE
- RFID_PLAIN
- RFID_RELATED
- RFID_PSK
- OCPP_NONE
- OCPP_RS
- OCPP_AUTH
- OCPP_RS_TLS
- OCPP_AUTH_TLS
- OCPP_CACHE
- OCPP_WHITELIST
- OCPP_CERTIFIED
- ISO15118_NONE
- ISO15118_PNC
- PLMN_NONE
- PLMN_RING
- PLMN_SMS
OCMFIdentificationType:string
NONE: No assignment available DENIED: Assignment currently not available (due to two-factor authorization) UNDEFINED: Type not specified ISO14443: UID of an RFID card according to ISO 14443. Represented as 4 or 7 bytes in hexadecimal notation. ISO15693: UID of an RFID card according to ISO 15693. Represented as 8 bytes in hexadecimal notation. EMAID: Electro-Mobility-Account-ID according to ISO/IEC 15118 (string with length 14 or 15) EVCCID: ID of an electric vehicle according to ISO/IEC 15118 (maximum length 6 characters) EVCOID: EV Contract ID according to DIN 91286. ISO7812: Identification card format according to ISO/IEC 7812 (credit and bank cards, etc.) CARD_TXN_NR: Card transaction number (CardTxNbr) for a payment with credit or bank card used in a terminal at the charging point. CENTRAL: Centrally generated ID. No exact format defined, can be e.g. a UUID. (OCPP 2.0) CENTRAL_1: Centrally generated ID, e.g. by start via SMS. No exact format defined. (until OCPP 1.6) CENTRAL_2: Centrally generated ID, e.g. by operator start. No exact format defined. (until OCPP 1.6) LOCAL: Locally generated ID. No exact format defined, might be e.g. a UUID. (OCPP 2.0) LOCAL_1: Locally generated ID, e.g. ID generated internally by the charge point. No exact format defined. (until OCPP 1.6) LOCAL_2: Locally generated ID, for other cases. No exact format defined. (until OCPP 1.6) PHONE_NUMBER: International phone number with leading “+”. KEY_CODE: User-related private key code. No exact format defined.
enum:
- NONE
- DENIED
- UNDEFINED
- ISO14443
- ISO15693
- EMAID
- EVCCID
- EVCOID
- ISO7812
- CARD_TXN_NR
- CENTRAL
- CENTRAL_1
- CENTRAL_2
- LOCAL
- LOCAL_1
- LOCAL_2
- PHONE_NUMBER
- KEY_CODE
OCMFUserIdentificationStatus:string
General status for user assignment ASSIGNED: user successfully assigned NOT_ASSIGNED: user not assigned
enum:
- ASSIGNED
- NOT_ASSIGNED
Powermeter:object
Measured dataset (AC or DC)
properties:
timestamp:string <required>
Timestamp of measurement
format:date-time
meter_id:string <optional>
A (user defined) meter if (e.g. id printed on the case)
phase_seq_error:boolean <optional>
AC only: true for 3 phase rotation error (ccw)
energy_Wh_import:object <required> (units-Energy)
Imported energy in Wh (from grid)
There is an extended definition for this object here.
energy_Wh_export:object <optional> (units-Energy)
Exported energy in Wh (to grid)
There is an extended definition for this object here.
power_W:object <optional> (units-Power)
Instantaneous power in Watt. Negative values are exported, positive values imported Energy.
There is an extended definition for this object here.
voltage_V:object <optional> (units-Voltage)
Voltage in Volts
There is an extended definition for this object here.
VAR:object <optional> (units-ReactivePower)
Reactive power VAR
There is an extended definition for this object here.
current_A:object <optional> (units-Current)
Current in ampere
There is an extended definition for this object here.
frequency_Hz:object <optional> (units-Frequency)
Grid frequency in Hertz
There is an extended definition for this object here.
energy_Wh_import_signed:object <optional> (units_signed-Energy)
Imported energy in Wh (from grid)
There is an extended definition for this object here.
energy_Wh_export_signed:object <optional> (units_signed-Energy)
Exported energy in Wh (to grid)
There is an extended definition for this object here.
power_W_signed:object <optional> (units_signed-Power)
Instantaneous power in Watt. Negative values are exported, positive values imported Energy.
There is an extended definition for this object here.
voltage_V_signed:object <optional> (units_signed-Voltage)
Voltage in Volts
There is an extended definition for this object here.
VAR_signed:object <optional> (units_signed-ReactivePower)
Reactive power VAR
There is an extended definition for this object here.
current_A_signed:object <optional> (units_signed-Current)
Current in ampere
There is an extended definition for this object here.
frequency_Hz_signed:object <optional> (units_signed-Frequency)
Grid frequency in Hertz
There is an extended definition for this object here.
signed_meter_value:object <optional> (units_signed-SignedMeterValue)
Signed collection of instantaneous meter values if supported by the meter. This is intended for meters that only support signing a collection of meter values.
There is an extended definition for this object here.
temperatures:array <optional>
An array of temperature sensors expressed in C, their definition and meaning is product specific
array_item:object (temperature-Temperature)

There is an extended definition for this object here.