  "reportFormat": "CTRF",
  "specVersion": "1.0.0",
  "results": {
    "tool": {
      "name": "Pionix ISO 15118 Conformance Tester"
    },
    "summary": {
      "tests": 5,
      "passed": 0,
      "failed": 4,
      "skipped": 1,
      "pending": 0,
      "other": 0,
      "start": 1791532801395,
      "stop": 1791532895692
    },
    "environment": {
      "appName": "EVerest",
      "appVersion": "testing/main",
      "commit": "ed063b5d908751f9a2b2642f8dc8118979580e82",
      "branchName": "main",
      "testEnvironment": "SIL",
      "osPlatform": "linux",
      "healthy": true,
      "buildUrl": "https://pionix-conformance-bot.github.io/Himalayas/reports/20261009T080333Z/"
    },
    "extra": {
      "build": {
        "status": "passed",
        "modules": [
          "Auth",
          "DummyTokenProvider",
          "DummyTokenValidator",
          "EnergyManager",
          "EnergyNode",
          "Evse15118D20",
          "EvseManager",
          "EvseSecurity",
          "EvseSlac"
        ]
      },
      "integrator": {
        "id": "pionix",
        "displayName": "Pionix GmbH"
      },
      "configuration": "ac-dc100",
      "reportUrl": "https://pionix-conformance-bot.github.io/Himalayas/reports/20261009T080333Z/ac-dc100/conformance-report.pdf"
    },
    "tests": [
      {
        "name": "TC_SECC_AC_VTB_CmSlacParm_003",
        "status": "failed",
        "duration": 17170,
        "suite": [
          "conformance",
          "ISO15118-5",
          "CmSlacParm"
        ],
        "tags": [
          "compliance",
          "ISO15118-3",
          "x-iso15118-5",
          "x-slac",
          "AC"
        ],
        "rawStatus": "FAIL",
        "message": "TimeoutError: CP E/F (duty 0) step not observed before the window closed (last duty=26.666667938232422)",
        "filePath": "tests/test_secc_ac_cm_slac_parm.py"
      },
      {
        "name": "TC_SECC_AC_VTB_PLCLinkStatus_009",
        "status": "skipped",
        "duration": 3820,
        "suite": [
          "conformance",
          "ISO15118-5",
          "PLCLinkStatus"
        ],
        "tags": [
          "compliance",
          "ISO15118-3",
          "x-iso15118-5",
          "x-slac",
          "AC",
          "x-rig-limitation"
        ],
        "rawStatus": "INCONCLUSIVE",
        "message": "NOT TESTABLE ON THIS RIG: requires a timed operator authorization at the station; not automatable",
        "filePath": "tests/test_secc_ac_plc_link_status.py"
      },
      {
        "name": "TC_SECC_AC_VTB_PLCLinkStatus_011",
        "status": "failed",
        "duration": 4897,
        "suite": [
          "conformance",
          "ISO15118-5",
          "PLCLinkStatus"
        ],
        "tags": [
          "compliance",
          "ISO15118-3",
          "x-iso15118-5",
          "x-slac",
          "AC",
          "x-inconclusive"
        ],
        "rawStatus": "INCONCLUSIVE",
        "message": "harness.verdict.PreconditionInconclusive: INCONCLUSIVE (dc100 GoodCase held at X1 (no EIM)): SUT not at X1 (100%) at connection-loss time (duty 26.666667938232422) -- the dc100 X1->E/F premise is not established\nassert (26.666667938232422 is not None and 26.666667938232422 >= 99.5)\n +  where 26.666667938232422 = <harness.test_ev.ConformanceTestEv object at 0x7f4e33a4cbd0>.duty\n +  and   26.666667938232422 = <harness.test_ev.ConformanceTestEv object at 0x7f4e33a4cbd0>.duty",
        "filePath": "tests/test_secc_ac_plc_link_status.py"
      },
      {
        "name": "TC_SECC_CMN_VTB_PaymentServiceSelection_009",
        "status": "failed",
        "duration": 34065,
        "suite": [
          "conformance",
          "ISO15118-4",
          "PaymentServiceSelection"
        ],
        "tags": [
          "compliance",
          "ISO15118-2",
          "x-iso15118-4",
          "AC"
        ],
        "rawStatus": "FAIL",
        "message": "TimeoutError: CP PWM duty ~5.0% (tol 1.5) not observed within 30.0s (last=26.666667938232422)",
        "filePath": "tests/test_secc_iso2_payment_service_selection.py"
      },
      {
        "name": "TC_SECC_CMN_VTB_SDP_007",
        "status": "failed",
        "duration": 34273,
        "suite": [
          "conformance",
          "ISO15118-4",
          "SDP"
        ],
        "tags": [
          "compliance",
          "ISO15118-2",
          "x-iso15118-4",
          "AC"
        ],
        "rawStatus": "FAIL",
        "message": "TimeoutError: CP PWM duty ~5.0% (tol 1.5) not observed within 30.0s (last=26.666667938232422)",
        "filePath": "tests/test_secc_iso2_transport.py"
      }
    ]
  }
}